From 89fee209b16e43fb0059e67e704cae5e33b4d081 Mon Sep 17 00:00:00 2001 From: Gabik21 Date: Fri, 23 Oct 2026 21:00:51 +0200 Subject: [PATCH 1/3] meters: document minsoc and maxsoc --- src/content/docs/de/reference/configuration/meters.md | 8 ++++++++ src/content/docs/de/user-defined-devices.mdx | 2 +- src/content/docs/en/reference/configuration/meters.md | 8 ++++++++ src/content/docs/en/user-defined-devices.mdx | 2 +- 4 files changed, 18 insertions(+), 2 deletions(-) diff --git a/src/content/docs/de/reference/configuration/meters.md b/src/content/docs/de/reference/configuration/meters.md index 163c6ddb12..d7fe427394 100644 --- a/src/content/docs/de/reference/configuration/meters.md +++ b/src/content/docs/de/reference/configuration/meters.md @@ -384,6 +384,8 @@ Standard Implementierung, bei welchem die einzelnen Werte über [Plugins](/de/us soc: # Batterie SOC (%) source: # Plugin Typ ... + minsoc: 10 # Minimaler Batterie-SOC (%) + maxsoc: 90 # Maximaler Batterie-SOC (%) capacity: # optional Batterie Kapazität (kWh) currents: # Stromstärke (A) pro Phase - source: # Phase 1 Plugin Typ @@ -479,6 +481,12 @@ Dient dazu, den Gesamt-Ladestand zu ermittlen. --- +#### `minsoc` und `maxsoc` + +Optionale untere und obere Grenzen des Batterie-Ladestands in Prozent. Trage hier die am Batteriesystem eingestellten Grenzen ein. evcc berücksichtigt sie bei der Berechnung des nutzbaren SOC-Bereichs, unter anderem für den Optimizer und das Netzladen. Die Standardwerte sind `0` und `100`. + +--- + #### `currents` Eine Liste von Plugin Definitionen um die Stromstärke in A pro Phase zurückzugeben. diff --git a/src/content/docs/de/user-defined-devices.mdx b/src/content/docs/de/user-defined-devices.mdx index df8a5fc797..db18a2826c 100644 --- a/src/content/docs/de/user-defined-devices.mdx +++ b/src/content/docs/de/user-defined-devices.mdx @@ -138,7 +138,7 @@ Echte Zählerstände liefern genauere Langzeitstatistiken. | Attribut | Typ | Erfordert | Kontext | Beschreibung | | ------------- | ----- | --------- | --------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| `limitsoc` | `int` | nein | `battery` | Setze Ladeziel für Batterie in %. Das Ladeziel wird aus den konfigurierten `MinSoc`, `MaxSoc` und dem aktuellen Ladestand (Attribut `soc`) berechnet. | +| `limitsoc` | `int` | nein | `battery` | Setze Ladeziel für Batterie in %. Das Ladeziel wird aus den konfigurierten `minsoc`, `maxsoc` und dem aktuellen Ladestand (Attribut `soc`) berechnet. | | `curtail` | `int` | nein | `pv` | Setze Einspeiselimit in % der Nennleistung der Erzeugung (0 bis 100, `100` = kein Limit). Nur zusammen mit `curtailed`. Siehe [Einspeisebegrenzer](#curtailer). | | `batterymode` | `int` | nein | `battery` | Setze den Steuerungsmodus der Batterie direkt. Die Modi sind unten aufgeführt. | diff --git a/src/content/docs/en/reference/configuration/meters.md b/src/content/docs/en/reference/configuration/meters.md index dfa0dfa3f1..30ee1d6607 100644 --- a/src/content/docs/en/reference/configuration/meters.md +++ b/src/content/docs/en/reference/configuration/meters.md @@ -380,6 +380,8 @@ Standard implementation, in which individual values are defined via [plugins](/e soc: # Battery SOC (%) source: # Plugin Type ... + minsoc: 10 # Minimum battery SOC (%) + maxsoc: 90 # Maximum battery SOC (%) capacity: # Optional Battery Capacity (kWh) currents: # Current (A) per phase - source: # Phase 1 Plugin Type @@ -473,6 +475,12 @@ Indication of battery capacity. Only useful when multiple batteries are present. --- +#### `minsoc` and `maxsoc` + +Optional lower and upper battery charge limits in percent. Set these to the limits configured on the battery system. evcc uses them when calculating the battery's usable SOC range, including for the optimizer and grid charging. The defaults are `0` and `100`. + +--- + #### `currents` A list of plugin definitions to return current in amperes (A) per phase. diff --git a/src/content/docs/en/user-defined-devices.mdx b/src/content/docs/en/user-defined-devices.mdx index 3be6e303b5..99d15ef4aa 100644 --- a/src/content/docs/en/user-defined-devices.mdx +++ b/src/content/docs/en/user-defined-devices.mdx @@ -137,7 +137,7 @@ Real meter readings give more accurate long-term statistics. | Attribute | Type | Required | Context | Description | | ------------- | ----- | -------- | --------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| `limitsoc` | `int` | no | `battery` | Set charging target for battery in %. The charging target is calculated from the configured `MinSoc`, `MaxSoc` and the current charge level (attribute `soc`). | +| `limitsoc` | `int` | no | `battery` | Set charging target for battery in %. The charging target is calculated from the configured `minsoc`, `maxsoc` and the current charge level (attribute `soc`). | | `curtail` | `int` | no | `pv` | Set grid export limit in % of the nominal production power (0 to 100, `100` = no limit). Only together with `curtailed`. See [Curtailment Device](#curtailer). | | `batterymode` | `int` | no | `battery` | Set the battery control mode directly. The modes are listed below. | From 6ad5c977d637dc5d8da4a77e921e6e346cf8fcbb Mon Sep 17 00:00:00 2001 From: Michael Geers Date: Tue, 24 Nov 2026 14:39:33 +0100 Subject: [PATCH 2/3] meters: battery only, charge level wording, plugin support --- .../docs/en/reference/configuration/meters.md | 36 +++++++++++++------ src/content/docs/en/user-defined-devices.mdx | 2 ++ 2 files changed, 28 insertions(+), 10 deletions(-) diff --git a/src/content/docs/en/reference/configuration/meters.md b/src/content/docs/en/reference/configuration/meters.md index bfe4c5f0d0..a65770242f 100644 --- a/src/content/docs/en/reference/configuration/meters.md +++ b/src/content/docs/en/reference/configuration/meters.md @@ -373,11 +373,11 @@ Standard implementation, in which individual values are defined via [plugins](/e returnenergy: # Energy in reverse direction (kWh) source: # Plugin Type ... - soc: # Battery SOC (%) + soc: # Charge level (%) source: # Plugin Type ... - minsoc: 10 # Minimum battery SOC (%) - maxsoc: 90 # Maximum battery SOC (%) + minsoc: 10 # Minimum charge level (%) + maxsoc: 90 # Maximum charge level (%) capacity: # Optional Battery Capacity (kWh) currents: # Current (A) per phase - source: # Phase 1 Plugin Type @@ -458,13 +458,35 @@ Plugin definition to return battery charge level in percentage (%). **For example**: ```yaml - soc: ... # Battery SOC (%) + soc: ... # Charge level (%) source: # Plugin Type ... ``` --- +#### `minsoc` and `maxsoc` + +Lower and upper charge level of the battery in percent, as set on the battery system. +Both only apply to batteries, i.e. together with `soc`. +The [optimizer](/en/features/optimizer) keeps the planned charge level within these limits. +Charging the battery from the grid stops at `maxsoc`, and discharging it to the grid stops at `minsoc`. +With [`limitsoc`](/en/user-defined-devices#meter-write-attributes), the [battery modes](/en/user-defined-devices#battery-modes) are set through these limits: `normal` writes `minsoc`, `charge` writes `maxsoc` and `holddischarge` writes the current charge level, at least `minsoc`. +The defaults are `0` and `100`. +Instead of a fixed value, any [float plugin](/en/reference/plugins) can read the limits from the device. +The plugin is read on every cycle, and a failed read keeps the last value. + +**For example**: + +```yaml + minsoc: 10 # Minimum charge level (%) + maxsoc: # read from the device instead of a fixed value + source: modbus + ... +``` + +--- + #### `capacity` Battery capacity in kWh. @@ -483,12 +505,6 @@ Until the first successful read, the capacity counts as unknown. --- -#### `minsoc` and `maxsoc` - -Optional lower and upper battery charge limits in percent. Set these to the limits configured on the battery system. evcc uses them when calculating the battery's usable SOC range, including for the optimizer and grid charging. The defaults are `0` and `100`. - ---- - #### `currents` A list of plugin definitions to return current in amperes (A) per phase. diff --git a/src/content/docs/en/user-defined-devices.mdx b/src/content/docs/en/user-defined-devices.mdx index a14ddae721..4b285bdf87 100644 --- a/src/content/docs/en/user-defined-devices.mdx +++ b/src/content/docs/en/user-defined-devices.mdx @@ -108,6 +108,8 @@ To convert, use the [reading pipelines](/en/reference/plugins#reading). | `curtailed` | `int` | no | `pv` | Current grid export limit in % (0 to 100). Only together with `curtail`. | | `soc` | `int` | no | `battery` | Charge level in % | | `capacity` | `float` | no | `battery` | Capacity in kWh | +| `minsoc` | `float` | no | `battery` | Minimum charge level in % as set on the battery system (default `0`) | +| `maxsoc` | `float` | no | `battery` | Maximum charge level in % as set on the battery system (default `100`) | | `powers` | `[float,float,float]` | no | all | Phase powers in W. For sign detection of unsigned currents. | | `currents` | `[float,float,float]` | no | all | Phase currents in A. For detecting active phases. | | `voltages` | `[float,float,float]` | no | all | Phase voltages in V. For connection detection (1p/3p). | From 4f468cacfcc966868dded15965d496fbbf68fe71 Mon Sep 17 00:00:00 2001 From: Michael Geers Date: Tue, 24 Nov 2026 14:44:03 +0100 Subject: [PATCH 3/3] chore: translate --- .../docs/cs/reference/configuration/meters.md | 30 +++++++++++++++-- src/content/docs/cs/user-defined-devices.mdx | 6 ++-- .../docs/da/reference/configuration/meters.md | 30 +++++++++++++++-- src/content/docs/da/user-defined-devices.mdx | 6 ++-- .../docs/de/reference/configuration/meters.md | 32 ++++++++++++++++--- src/content/docs/de/user-defined-devices.mdx | 30 +++++++++-------- .../docs/fr/reference/configuration/meters.md | 30 +++++++++++++++-- src/content/docs/fr/user-defined-devices.mdx | 30 +++++++++-------- .../docs/it/reference/configuration/meters.md | 30 +++++++++++++++-- src/content/docs/it/user-defined-devices.mdx | 30 +++++++++-------- .../docs/nl/reference/configuration/meters.md | 30 +++++++++++++++-- src/content/docs/nl/user-defined-devices.mdx | 6 ++-- 12 files changed, 223 insertions(+), 67 deletions(-) diff --git a/src/content/docs/cs/reference/configuration/meters.md b/src/content/docs/cs/reference/configuration/meters.md index 40a8ecd48b..0d1543624e 100644 --- a/src/content/docs/cs/reference/configuration/meters.md +++ b/src/content/docs/cs/reference/configuration/meters.md @@ -3,7 +3,7 @@ title: "meters" description: "Jak v evcc.yaml definovat měřiče pro síť, solár, domácí baterii a spotřebiče, jaká znaménková konvence platí a které typy měřičů jsou k dispozici." sidebar: order: 5 -translatedFrom: "469542e8d8c5" +translatedFrom: "a65770242fcb" --- _Měřiče_ (elektroměry) jsou seznam zařízení v domě, která dokážou měřit výkon a spotřebu energie, výrobu ze soláru nebo využití domácí baterie. `meter` definuje bod měření energie. Může jít o fyzické zařízení (např. měřič v předávacím místě sítě), solární střídač (AC, nebo u hybridních střídačů DC) nebo bateriový střídač. @@ -374,9 +374,11 @@ Standardní implementace, u které se jednotlivé hodnoty definují pomocí [pl returnenergy: # Energie v opačném směru (kWh) source: # Typ pluginu ... - soc: # Stav nabití baterie (%) + soc: # Stav nabití (%) source: # Typ pluginu ... + minsoc: 10 # Minimální stav nabití (%) + maxsoc: 90 # Maximální stav nabití (%) capacity: # Volitelná kapacita baterie (kWh) currents: # Proud (A) na fázi - source: # Typ pluginu pro fázi 1 @@ -457,13 +459,35 @@ Definice pluginu, který vrací stav nabití baterie v procentech (%). **Příklad**: ```yaml - soc: ... # Stav nabití baterie (%) + soc: ... # Stav nabití (%) source: # Typ pluginu ... ``` --- +#### `minsoc` a `maxsoc` + +Dolní a horní mez stavu nabití baterie v procentech, jak je nastavena v bateriovém systému. +Obě platí jen pro baterie, tj. společně se `soc`. +[Optimalizátor](/cs/features/optimizer) udržuje plánovaný stav nabití v těchto mezích. +Nabíjení baterie ze sítě se zastaví na hodnotě `maxsoc` a vybíjení do sítě na hodnotě `minsoc`. +S [`limitsoc`](/cs/user-defined-devices#meter-write-attributes) se [režimy baterie](/cs/user-defined-devices#battery-modes) nastavují prostřednictvím těchto mezí: `normal` zapisuje `minsoc`, `charge` zapisuje `maxsoc` a `holddischarge` zapisuje aktuální stav nabití, nejméně však `minsoc`. +Výchozí hodnoty jsou `0` a `100`. +Místo pevné hodnoty může meze ze zařízení načíst libovolný [plugin, který vrací desetinné číslo](/cs/reference/plugins). +Plugin se načítá v každém cyklu a při neúspěšném načtení zůstává poslední hodnota. + +**Příklad**: + +```yaml + minsoc: 10 # Minimální stav nabití (%) + maxsoc: # načtení ze zařízení místo pevné hodnoty + source: modbus + ... +``` + +--- + #### `capacity` Kapacita baterie v kWh. diff --git a/src/content/docs/cs/user-defined-devices.mdx b/src/content/docs/cs/user-defined-devices.mdx index 4a3f12b576..a02a94f327 100644 --- a/src/content/docs/cs/user-defined-devices.mdx +++ b/src/content/docs/cs/user-defined-devices.mdx @@ -3,7 +3,7 @@ title: Zařízení definovaná uživatelem description: "Připojte nabíječku, měřič, vozidlo nebo topení, pro které neexistuje vestavěná šablona, a jejich hodnoty i ovládání si definujte sami přes HTTP, MQTT nebo Modbus." tableOfContents: maxHeadingLevel: 4 -translatedFrom: "161eb222a89c" +translatedFrom: "4b285bdf874c" --- import { Tabs, TabItem } from "@astrojs/starlight/components"; @@ -109,6 +109,8 @@ Pro převod použijte [čtecí pipeline](/cs/reference/plugins#reading). | `curtailed` | `int` | ne | `pv` | Aktuální limit exportu do sítě v % (0 až 100). Pouze společně s `curtail`. | | `soc` | `int` | ne | `battery` | Stav nabití v % | | `capacity` | `float` | ne | `battery` | Kapacita v kWh | +| `minsoc` | `float` | ne | `battery` | Minimální stav nabití v % nastavený v bateriovém systému (výchozí `0`) | +| `maxsoc` | `float` | ne | `battery` | Maximální stav nabití v % nastavený v bateriovém systému (výchozí `100`) | | `powers` | `[float,float,float]` | ne | vše | Fázové výkony ve W. Pro určení znaménka u proudů bez znaménka. | | `currents` | `[float,float,float]` | ne | vše | Fázové proudy v A. Pro zjištění aktivních fází. | | `voltages` | `[float,float,float]` | ne | vše | Fázová napětí ve V. Pro zjištění zapojení (1f/3f). | @@ -138,7 +140,7 @@ Skutečné stavy měřiče poskytují přesnější dlouhodobé statistiky. | Atribut | Typ | Povinné | Kontext | Popis | | ------------- | ----- | ------- | --------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | -| `limitsoc` | `int` | ne | `battery` | Nastaví cíl nabíjení baterie v %. Cíl nabíjení se vypočítá z nakonfigurovaných `MinSoc`, `MaxSoc` a aktuálního stavu nabití (atribut `soc`). | +| `limitsoc` | `int` | ne | `battery` | Nastaví cíl nabíjení baterie v %. Cíl nabíjení se vypočítá z nakonfigurovaných `minsoc`, `maxsoc` a aktuálního stavu nabití (atribut `soc`). | | `curtail` | `int` | ne | `pv` | Nastaví limit exportu do sítě v % jmenovitého výkonu výroby (0 až 100, `100` = bez limitu). Pouze společně s `curtailed`. Viz [Zařízení pro omezení výkonu](#curtailer). | | `batterymode` | `int` | ne | `battery` | Přímo nastaví režim řízení baterie. Režimy jsou uvedeny níže. | diff --git a/src/content/docs/da/reference/configuration/meters.md b/src/content/docs/da/reference/configuration/meters.md index a290caf6df..88dcda754c 100644 --- a/src/content/docs/da/reference/configuration/meters.md +++ b/src/content/docs/da/reference/configuration/meters.md @@ -3,7 +3,7 @@ title: "meters" description: "Sådan definerer du målere i evcc.yaml til elnet, sol, hjemmebatteri og forbrugsenheder, hvilken fortegnskonvention der gælder, og hvilke målertyper der findes." sidebar: order: 5 -translatedFrom: "469542e8d8c5" +translatedFrom: "a65770242fcb" --- Under _målere_ (elmålere) angiver du de enheder i huset, der kan måle effekt- og energiforbrug, solproduktion eller brugen af hjemmebatteriet. En `meter` definerer et målepunkt for energi og kan være en fysisk enhed (f.eks. en måler ved tilslutningspunktet til elnettet), en solcelleinverter (AC eller DC ved hybridinvertere) eller en batteriinverter. @@ -374,9 +374,11 @@ Standardimplementering, hvor de enkelte værdier defineres via [plugins](/da/use returnenergy: # Energi i modsat retning (kWh) source: # Plugin-type ... - soc: # Batteriets opladningsniveau (%) + soc: # Opladningsniveau (%) source: # Plugin-type ... + minsoc: 10 # Minimalt opladningsniveau (%) + maxsoc: 90 # Maksimalt opladningsniveau (%) capacity: # Valgfri batterikapacitet (kWh) currents: # Strøm (A) pr. fase - source: # Fase 1: plugin-type @@ -457,13 +459,35 @@ Plugin-definition, der leverer batteriets opladningsniveau i procent (%). **Eksempel**: ```yaml - soc: ... # Batteriets opladningsniveau (%) + soc: ... # Opladningsniveau (%) source: # Plugin-type ... ``` --- +#### `minsoc` og `maxsoc` + +Batteriets nedre og øvre opladningsniveau i procent, som indstillet på batterisystemet. +Begge gælder kun for batterier, dvs. sammen med `soc`. +[Optimizeren](/da/features/optimizer) holder det planlagte opladningsniveau inden for disse grænser. +Opladning af batteriet fra elnettet stopper ved `maxsoc`, og afladning til elnettet stopper ved `minsoc`. +Med [`limitsoc`](/da/user-defined-devices#meter-write-attributes) indstilles [batteritilstandene](/da/user-defined-devices#battery-modes) via disse grænser: `normal` skriver `minsoc`, `charge` skriver `maxsoc`, og `holddischarge` skriver det aktuelle opladningsniveau, dog mindst `minsoc`. +Standardværdierne er `0` og `100`. +I stedet for en fast værdi kan et vilkårligt [float-plugin](/da/reference/plugins) læse grænserne fra enheden. +Pluginet læses ved hver cyklus, og ved en mislykket læsning bevares den sidste værdi. + +**Eksempel**: + +```yaml + minsoc: 10 # Minimalt opladningsniveau (%) + maxsoc: # læses fra enheden i stedet for en fast værdi + source: modbus + ... +``` + +--- + #### `capacity` Batteriets kapacitet i kWh. diff --git a/src/content/docs/da/user-defined-devices.mdx b/src/content/docs/da/user-defined-devices.mdx index e3e9e99e3a..1c078a2cdc 100644 --- a/src/content/docs/da/user-defined-devices.mdx +++ b/src/content/docs/da/user-defined-devices.mdx @@ -3,7 +3,7 @@ title: Brugerdefinerede enheder description: "Du kan integrere en oplader, en måler, et køretøj eller en varmeenhed uden indbygget skabelon ved selv at definere aflæsning og styring via HTTP, MQTT eller Modbus." tableOfContents: maxHeadingLevel: 4 -translatedFrom: "161eb222a89c" +translatedFrom: "4b285bdf874c" --- import { Tabs, TabItem } from "@astrojs/starlight/components"; @@ -109,6 +109,8 @@ Til konvertering bruges [læse-pipelines](/da/reference/plugins#reading). | `curtailed` | `int` | nej | `pv` | Aktuel grænse for eksport til elnettet i % (0 til 100). Kun sammen med `curtail`. | | `soc` | `int` | nej | `battery` | Opladningsniveau i % | | `capacity` | `float` | nej | `battery` | Kapacitet i kWh | +| `minsoc` | `float` | nej | `battery` | Minimalt opladningsniveau i % som indstillet på batterisystemet (standard `0`) | +| `maxsoc` | `float` | nej | `battery` | Maksimalt opladningsniveau i % som indstillet på batterisystemet (standard `100`) | | `powers` | `[float,float,float]` | nej | alle | Faseeffekter i W. Til fortegnsgenkendelse ved strømme uden fortegn. | | `currents` | `[float,float,float]` | nej | alle | Fasestrømme i A. Til genkendelse af aktive faser. | | `voltages` | `[float,float,float]` | nej | alle | Fasespændinger i V. Til genkendelse af tilslutningen (1p/3p). | @@ -138,7 +140,7 @@ Rigtige målerstande giver mere præcise langtidsstatistikker. | Attribut | Type | Påkrævet | Kontekst | Beskrivelse | | ------------- | ----- | -------- | --------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| `limitsoc` | `int` | nej | `battery` | Sæt batteriets opladningsmål i %. Opladningsmålet beregnes ud fra de konfigurerede `MinSoc` og `MaxSoc` samt det aktuelle opladningsniveau (attribut `soc`). | +| `limitsoc` | `int` | nej | `battery` | Sæt batteriets opladningsmål i %. Opladningsmålet beregnes ud fra de konfigurerede `minsoc` og `maxsoc` samt det aktuelle opladningsniveau (attribut `soc`). | | `curtail` | `int` | nej | `pv` | Sæt grænsen for eksport til elnettet i % af den nominelle produktionseffekt (0 til 100, `100` = ingen grænse). Kun sammen med `curtailed`. Se [Enhed til effektbegrænsning](#curtailer). | | `batterymode` | `int` | nej | `battery` | Sæt batteriets styringstilstand direkte. Tilstandene er angivet nedenfor. | diff --git a/src/content/docs/de/reference/configuration/meters.md b/src/content/docs/de/reference/configuration/meters.md index 98e4253b45..fa8619b538 100644 --- a/src/content/docs/de/reference/configuration/meters.md +++ b/src/content/docs/de/reference/configuration/meters.md @@ -3,7 +3,7 @@ title: "meters" description: "Hier steht, wie du Zähler für Netz, PV-Anlage, Hausbatterie und Verbraucher in der evcc.yaml definierst, welche Vorzeichen gelten und welche Zählertypen es gibt." sidebar: order: 5 -translatedFrom: "469542e8d8c5" +translatedFrom: "a65770242fcb" --- Unter _meters_ (Zähler) steht eine Liste von Geräten im Haus, die Leistung und Energie messen können, etwa für den Verbrauch, die PV-Erzeugung oder die Hausbatterie. Ein `meter` definiert einen Messpunkt für Energie und kann ein physisches Gerät sein (z. B. ein Zähler am Netzanschlusspunkt), ein PV-Wechselrichter (AC oder bei Hybridwechselrichtern auch DC) oder ein Batteriewechselrichter. @@ -374,9 +374,11 @@ Generische Implementierung, bei der die einzelnen Werte über [Plugins](/de/user returnenergy: # Energie in Gegenrichtung (kWh) source: # Plugin-Typ ... - soc: # Ladestand der Batterie (%) + soc: # Ladestand (%) source: # Plugin-Typ ... + minsoc: 10 # Minimaler Ladestand (%) + maxsoc: 90 # Maximaler Ladestand (%) capacity: # optional: Batteriekapazität (kWh) currents: # Strom (A) pro Phase - source: # Plugin-Typ Phase 1 @@ -457,13 +459,35 @@ Plugin-Definition, die den Ladestand der Batterie in Prozent (%) liefert. **Beispiel**: ```yaml - soc: ... # Ladestand der Batterie (%) + soc: ... # Ladestand (%) source: # Plugin-Typ ... ``` --- +#### `minsoc` und `maxsoc` + +Unterer und oberer Ladestand der Batterie in Prozent, wie im Batteriesystem eingestellt. +Beide gelten nur für Batterien, also zusammen mit `soc`. +Der [Optimizer](/de/features/optimizer) hält den geplanten Ladestand innerhalb dieser Grenzen. +Das Laden der Batterie aus dem Netz endet bei `maxsoc`, das Entladen ins Netz bei `minsoc`. +Mit [`limitsoc`](/de/user-defined-devices#meter-write-attributes) werden die [Batteriemodi](/de/user-defined-devices#battery-modes) über diese Grenzen gesetzt: `normal` schreibt `minsoc`, `charge` schreibt `maxsoc` und `holddischarge` schreibt den aktuellen Ladestand, mindestens aber `minsoc`. +Die Standardwerte sind `0` und `100`. +Statt eines festen Werts kann jedes [Float-Plugin](/de/reference/plugins) die Grenzen aus dem Gerät auslesen. +Das Plugin wird in jedem Zyklus ausgelesen, und bei einem fehlgeschlagenen Auslesen bleibt der letzte Wert erhalten. + +**Beispiel**: + +```yaml + minsoc: 10 # Minimaler Ladestand (%) + maxsoc: # aus dem Gerät gelesen statt eines festen Werts + source: modbus + ... +``` + +--- + #### `capacity` Batteriekapazität in kWh. @@ -475,7 +499,7 @@ Bis zum ersten erfolgreichen Auslesen gilt die Kapazität als unbekannt. **Beispiel**: ```yaml - capacity: # aus dem Gerät gelesen statt fester Wert + capacity: # aus dem Gerät gelesen statt eines festen Werts source: modbus ... ``` diff --git a/src/content/docs/de/user-defined-devices.mdx b/src/content/docs/de/user-defined-devices.mdx index bc819569d6..4e6850c512 100644 --- a/src/content/docs/de/user-defined-devices.mdx +++ b/src/content/docs/de/user-defined-devices.mdx @@ -3,7 +3,7 @@ title: Benutzerdefinierte Geräte description: "Zeigt, wie du Wallboxen, Zähler, Fahrzeuge oder Heizungen ohne eingebaute Vorlage einbindest und Messwerte und Steuerung selbst per HTTP, MQTT oder Modbus definierst." tableOfContents: maxHeadingLevel: 4 -translatedFrom: "161eb222a89c" +translatedFrom: "4b285bdf874c" --- import { Tabs, TabItem } from "@astrojs/starlight/components"; @@ -100,18 +100,20 @@ Zur Konvertierung dienen die [Lese-Pipelines](/de/reference/plugins#reading). ### Leseattribute -| Attribut | Typ | Erforderlich | Kontext | Beschreibung | -| -------------- | --------------------- | ------------ | ------------- | --------------------------------------------------------------------------- | -| `power` | `float` | ja | alle | Aktuelle Leistung in W | -| `energy` | `float` | nein | alle | Zählerstand in kWh | -| `returnenergy` | `float` | nein | alle | Zählerstand in Gegenrichtung in kWh (siehe unten) | -| `maxpower` | `int` | nein | `pv` (hybrid) | Maximale AC-Leistung in W | -| `curtailed` | `int` | nein | `pv` | Aktuelles Einspeiselimit in % (0 bis 100). Nur zusammen mit `curtail`. | -| `soc` | `int` | nein | `battery` | Ladestand in % | -| `capacity` | `float` | nein | `battery` | Kapazität in kWh | -| `powers` | `[float,float,float]` | nein | alle | Phasenleistungen in W. Zur Vorzeichenerkennung bei vorzeichenlosen Strömen. | -| `currents` | `[float,float,float]` | nein | alle | Phasenströme in A. Zur Erkennung aktiver Phasen. | -| `voltages` | `[float,float,float]` | nein | alle | Phasenspannungen in V. Zur Anschlusserkennung (1p/3p). | +| Attribut | Typ | Erforderlich | Kontext | Beschreibung | +| -------------- | --------------------- | ------------ | ------------- | ---------------------------------------------------------------------------- | +| `power` | `float` | ja | alle | Aktuelle Leistung in W | +| `energy` | `float` | nein | alle | Zählerstand in kWh | +| `returnenergy` | `float` | nein | alle | Zählerstand in Gegenrichtung in kWh (siehe unten) | +| `maxpower` | `int` | nein | `pv` (hybrid) | Maximale AC-Leistung in W | +| `curtailed` | `int` | nein | `pv` | Aktuelles Einspeiselimit in % (0 bis 100). Nur zusammen mit `curtail`. | +| `soc` | `int` | nein | `battery` | Ladestand in % | +| `capacity` | `float` | nein | `battery` | Kapazität in kWh | +| `minsoc` | `float` | nein | `battery` | Minimaler Ladestand in %, wie am Batteriesystem eingestellt (Standard `0`) | +| `maxsoc` | `float` | nein | `battery` | Maximaler Ladestand in %, wie am Batteriesystem eingestellt (Standard `100`) | +| `powers` | `[float,float,float]` | nein | alle | Phasenleistungen in W. Zur Vorzeichenerkennung bei vorzeichenlosen Strömen. | +| `currents` | `[float,float,float]` | nein | alle | Phasenströme in A. Zur Erkennung aktiver Phasen. | +| `voltages` | `[float,float,float]` | nein | alle | Phasenspannungen in V. Zur Anschlusserkennung (1p/3p). | ### Vorzeichen und Richtungen \{#signs-and-directions\} @@ -138,7 +140,7 @@ Echte Zählerstände liefern genauere Langzeitstatistiken. | Attribut | Typ | Erforderlich | Kontext | Beschreibung | | ------------- | ----- | ------------ | --------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| `limitsoc` | `int` | nein | `battery` | Setzt das Ladeziel der Batterie in %. Das Ladeziel wird aus den konfigurierten `MinSoc`, `MaxSoc` und dem aktuellen Ladestand (Attribut `soc`) berechnet. | +| `limitsoc` | `int` | nein | `battery` | Setzt das Ladeziel der Batterie in %. Das Ladeziel wird aus den konfigurierten `minsoc`, `maxsoc` und dem aktuellen Ladestand (Attribut `soc`) berechnet. | | `curtail` | `int` | nein | `pv` | Setzt das Einspeiselimit in % der Nennleistung der Erzeugung (0 bis 100, `100` = kein Limit). Nur zusammen mit `curtailed`. Siehe [Einspeisebegrenzer](#curtailer). | | `batterymode` | `int` | nein | `battery` | Setzt den Steuerungsmodus der Batterie direkt. Die Modi sind unten aufgeführt. | diff --git a/src/content/docs/fr/reference/configuration/meters.md b/src/content/docs/fr/reference/configuration/meters.md index 5f6a368fcb..1fe6aa9b29 100644 --- a/src/content/docs/fr/reference/configuration/meters.md +++ b/src/content/docs/fr/reference/configuration/meters.md @@ -3,7 +3,7 @@ title: "meters" description: "Définissez dans evcc.yaml les compteurs du réseau, du solaire, de la batterie domestique et des consommateurs, avec la convention de signe et les types disponibles." sidebar: order: 5 -translatedFrom: "469542e8d8c5" +translatedFrom: "a65770242fcb" --- Les _meters_ (compteurs) sont une liste d’appareils de la maison capables de mesurer la puissance et la consommation d’énergie, la production solaire ou l’utilisation de la batterie domestique. Un `meter` définit un point de mesure de l’énergie et peut être un appareil physique (p. ex. un compteur au point de raccordement au réseau), un onduleur solaire (AC ou DC dans le cas des onduleurs hybrides) ou un onduleur de batterie. @@ -374,9 +374,11 @@ Implémentation générique dans laquelle chaque valeur est fournie par des [plu returnenergy: # Énergie dans le sens inverse (kWh) source: # Type de plugin ... - soc: # Niveau de charge de la batterie (%) + soc: # Niveau de charge (%) source: # Type de plugin ... + minsoc: 10 # Niveau de charge minimal (%) + maxsoc: 90 # Niveau de charge maximal (%) capacity: # Capacité de la batterie, facultative (kWh) currents: # Courant (A) par phase - source: # Type de plugin pour la phase 1 @@ -457,13 +459,35 @@ Définition de plugin qui renvoie le niveau de charge de la batterie en pourcent **Exemple** : ```yaml - soc: ... # Niveau de charge de la batterie (%) + soc: ... # Niveau de charge (%) source: # Type de plugin ... ``` --- +#### `minsoc` et `maxsoc` + +Niveaux de charge inférieur et supérieur de la batterie en pourcentage, tels que réglés sur le système de batterie. +Les deux ne s’appliquent qu’aux batteries, c.-à-d. en combinaison avec `soc`. +L’[optimiseur](/fr/features/optimizer) maintient le niveau de charge planifié dans ces limites. +La charge de la batterie depuis le réseau s’arrête à `maxsoc`, et sa décharge vers le réseau s’arrête à `minsoc`. +Avec [`limitsoc`](/fr/user-defined-devices#meter-write-attributes), les [modes de batterie](/fr/user-defined-devices#battery-modes) sont appliqués via ces limites : `normal` écrit `minsoc`, `charge` écrit `maxsoc` et `holddischarge` écrit le niveau de charge actuel, au minimum `minsoc`. +Les valeurs par défaut sont `0` et `100`. +Au lieu d’une valeur fixe, n’importe quel [plugin de type float](/fr/reference/plugins) peut lire les limites depuis l’appareil. +Le plugin est lu à chaque cycle, et en cas d’échec de lecture, la dernière valeur est conservée. + +**Exemple** : + +```yaml + minsoc: 10 # Niveau de charge minimal (%) + maxsoc: # lu depuis l’appareil au lieu d’une valeur fixe + source: modbus + ... +``` + +--- + #### `capacity` Capacité de la batterie en kWh. diff --git a/src/content/docs/fr/user-defined-devices.mdx b/src/content/docs/fr/user-defined-devices.mdx index b2133fccfd..815e647df3 100644 --- a/src/content/docs/fr/user-defined-devices.mdx +++ b/src/content/docs/fr/user-defined-devices.mdx @@ -3,7 +3,7 @@ title: Appareils personnalisés description: "Intégrez un chargeur, un compteur, un véhicule ou un chauffage sans modèle intégré en définissant vous-même ses valeurs et commandes via HTTP, MQTT ou Modbus." tableOfContents: maxHeadingLevel: 4 -translatedFrom: "161eb222a89c" +translatedFrom: "4b285bdf874c" --- import { Tabs, TabItem } from "@astrojs/starlight/components"; @@ -100,18 +100,20 @@ Pour la conversion, utilisez les [pipelines de lecture](/fr/reference/plugins#re ### Attributs de lecture -| Attribut | Type | Obligatoire | Contexte | Description | -| -------------- | --------------------- | ----------- | -------------- | ---------------------------------------------------------------------------------- | -| `power` | `float` | oui | tous | Puissance actuelle en W | -| `energy` | `float` | non | tous | Index du compteur en kWh | -| `returnenergy` | `float` | non | tous | Index du compteur dans le sens inverse en kWh (voir ci-dessous) | -| `maxpower` | `int` | non | `pv` (hybride) | Puissance AC maximale en W | -| `curtailed` | `int` | non | `pv` | Limite actuelle d’export vers le réseau en % (0 à 100). Uniquement avec `curtail`. | -| `soc` | `int` | non | `battery` | Niveau de charge en % | -| `capacity` | `float` | non | `battery` | Capacité en kWh | -| `powers` | `[float,float,float]` | non | tous | Puissances par phase en W. Pour détecter le signe des courants non signés. | -| `currents` | `[float,float,float]` | non | tous | Courants par phase en A. Pour détecter les phases actives. | -| `voltages` | `[float,float,float]` | non | tous | Tensions par phase en V. Pour détecter le raccordement (1p/3p). | +| Attribut | Type | Obligatoire | Contexte | Description | +| -------------- | --------------------- | ----------- | -------------- | ----------------------------------------------------------------------------------------- | +| `power` | `float` | oui | tous | Puissance actuelle en W | +| `energy` | `float` | non | tous | Index du compteur en kWh | +| `returnenergy` | `float` | non | tous | Index du compteur dans le sens inverse en kWh (voir ci-dessous) | +| `maxpower` | `int` | non | `pv` (hybride) | Puissance AC maximale en W | +| `curtailed` | `int` | non | `pv` | Limite actuelle d’export vers le réseau en % (0 à 100). Uniquement avec `curtail`. | +| `soc` | `int` | non | `battery` | Niveau de charge en % | +| `capacity` | `float` | non | `battery` | Capacité en kWh | +| `minsoc` | `float` | non | `battery` | Niveau de charge minimal en % tel que réglé sur le système de batterie (par défaut `0`) | +| `maxsoc` | `float` | non | `battery` | Niveau de charge maximal en % tel que réglé sur le système de batterie (par défaut `100`) | +| `powers` | `[float,float,float]` | non | tous | Puissances par phase en W. Pour détecter le signe des courants non signés. | +| `currents` | `[float,float,float]` | non | tous | Courants par phase en A. Pour détecter les phases actives. | +| `voltages` | `[float,float,float]` | non | tous | Tensions par phase en V. Pour détecter le raccordement (1p/3p). | ### Signes et sens \{#signs-and-directions\} @@ -138,7 +140,7 @@ De vrais index de compteur donnent des statistiques à long terme plus précises | Attribut | Type | Obligatoire | Contexte | Description | | ------------- | ----- | ----------- | --------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| `limitsoc` | `int` | non | `battery` | Définit l’objectif de charge de la batterie en %. L’objectif de charge est calculé à partir des valeurs configurées `MinSoc` et `MaxSoc` et du niveau de charge actuel (attribut `soc`). | +| `limitsoc` | `int` | non | `battery` | Définit l’objectif de charge de la batterie en %. L’objectif de charge est calculé à partir des valeurs configurées `minsoc` et `maxsoc` et du niveau de charge actuel (attribut `soc`). | | `curtail` | `int` | non | `pv` | Définit la limite d’export vers le réseau en % de la puissance de production nominale (0 à 100, `100` = aucune limite). Uniquement avec `curtailed`. Voir [Appareil de bridage](#curtailer). | | `batterymode` | `int` | non | `battery` | Définit directement le mode de pilotage de la batterie. Les modes sont listés ci-dessous. | diff --git a/src/content/docs/it/reference/configuration/meters.md b/src/content/docs/it/reference/configuration/meters.md index 937af5c258..5f32632a39 100644 --- a/src/content/docs/it/reference/configuration/meters.md +++ b/src/content/docs/it/reference/configuration/meters.md @@ -3,7 +3,7 @@ title: "meters" description: "Definisci in evcc.yaml i contatori per rete, impianto fotovoltaico, batteria domestica e consumatori, e scopri la convenzione dei segni e i tipi di contatore disponibili." sidebar: order: 5 -translatedFrom: "469542e8d8c5" +translatedFrom: "a65770242fcb" --- I _contatori_ (strumenti di misura) sono i dispositivi della casa che possono misurare potenza e consumo di energia, produzione solare o utilizzo della batteria domestica. Un `meter` definisce un punto di misurazione dell’energia e può essere un dispositivo fisico (ad es. un contatore al punto di connessione alla rete), un inverter solare (AC o, nel caso di inverter ibridi, DC) o un inverter per batterie. @@ -374,9 +374,11 @@ Implementazione generica in cui i singoli valori vengono definiti tramite [plugi returnenergy: # Energia nel verso opposto (kWh) source: # Tipo di plugin ... - soc: # Livello di carica della batteria (%) + soc: # Livello di carica (%) source: # Tipo di plugin ... + minsoc: 10 # Livello di carica minimo (%) + maxsoc: 90 # Livello di carica massimo (%) capacity: # Capacità della batteria, opzionale (kWh) currents: # Corrente (A) per fase - source: # Tipo di plugin per la fase 1 @@ -457,13 +459,35 @@ Definizione del plugin che restituisce il livello di carica della batteria in pe **Ad esempio**: ```yaml - soc: ... # Livello di carica della batteria (%) + soc: ... # Livello di carica (%) source: # Tipo di plugin ... ``` --- +#### `minsoc` e `maxsoc` + +Livello di carica inferiore e superiore della batteria in percentuale, come impostato sul sistema di accumulo. +Entrambi valgono solo per le batterie, cioè insieme a `soc`. +L’[ottimizzatore](/it/features/optimizer) mantiene il livello di carica pianificato entro questi limiti. +La carica della batteria dalla rete si ferma a `maxsoc` e la scarica verso la rete si ferma a `minsoc`. +Con [`limitsoc`](/it/user-defined-devices#meter-write-attributes), le [modalità della batteria](/it/user-defined-devices#battery-modes) vengono impostate tramite questi limiti: `normal` scrive `minsoc`, `charge` scrive `maxsoc` e `holddischarge` scrive il livello di carica attuale, almeno `minsoc`. +I valori predefiniti sono `0` e `100`. +Al posto di un valore fisso, un qualsiasi [plugin float](/it/reference/plugins) può leggere i limiti dal dispositivo. +Il plugin viene letto a ogni ciclo e, se una lettura non riesce, viene mantenuto l’ultimo valore. + +**Ad esempio**: + +```yaml + minsoc: 10 # Livello di carica minimo (%) + maxsoc: # letto dal dispositivo invece di un valore fisso + source: modbus + ... +``` + +--- + #### `capacity` Capacità della batteria in kWh. diff --git a/src/content/docs/it/user-defined-devices.mdx b/src/content/docs/it/user-defined-devices.mdx index 6f93e97bce..f5967b7e94 100644 --- a/src/content/docs/it/user-defined-devices.mdx +++ b/src/content/docs/it/user-defined-devices.mdx @@ -3,7 +3,7 @@ title: Dispositivi definiti dall’utente description: "Mostra come integrare un caricabatterie, un contatore, un veicolo o un riscaldatore senza template integrato, definendo letture e comandi via HTTP, MQTT o Modbus." tableOfContents: maxHeadingLevel: 4 -translatedFrom: "161eb222a89c" +translatedFrom: "4b285bdf874c" --- import { Tabs, TabItem } from "@astrojs/starlight/components"; @@ -100,18 +100,20 @@ Per convertirlo, usa le [pipeline di lettura](/it/reference/plugins#reading). ### Attributi di lettura -| Attributo | Tipo | Obbligatorio | Contesto | Descrizione | -| -------------- | --------------------- | ------------ | ------------- | --------------------------------------------------------------------------------- | -| `power` | `float` | sì | tutti | Potenza attuale in W | -| `energy` | `float` | no | tutti | Lettura del contatore in kWh | -| `returnenergy` | `float` | no | tutti | Lettura del contatore in direzione inversa in kWh (vedi sotto) | -| `maxpower` | `int` | no | `pv` (ibrido) | Potenza AC massima in W | -| `curtailed` | `int` | no | `pv` | Limite attuale di immissione in rete in % (da 0 a 100). Solo insieme a `curtail`. | -| `soc` | `int` | no | `battery` | Livello di carica in % | -| `capacity` | `float` | no | `battery` | Capacità in kWh | -| `powers` | `[float,float,float]` | no | tutti | Potenze di fase in W. Per riconoscere il segno di correnti senza segno. | -| `currents` | `[float,float,float]` | no | tutti | Correnti di fase in A. Per riconoscere le fasi attive. | -| `voltages` | `[float,float,float]` | no | tutti | Tensioni di fase in V. Per riconoscere il tipo di collegamento (1p/3p). | +| Attributo | Tipo | Obbligatorio | Contesto | Descrizione | +| -------------- | --------------------- | ------------ | ------------- | ----------------------------------------------------------------------------------------- | +| `power` | `float` | sì | tutti | Potenza attuale in W | +| `energy` | `float` | no | tutti | Lettura del contatore in kWh | +| `returnenergy` | `float` | no | tutti | Lettura del contatore in direzione inversa in kWh (vedi sotto) | +| `maxpower` | `int` | no | `pv` (ibrido) | Potenza AC massima in W | +| `curtailed` | `int` | no | `pv` | Limite attuale di immissione in rete in % (da 0 a 100). Solo insieme a `curtail`. | +| `soc` | `int` | no | `battery` | Livello di carica in % | +| `capacity` | `float` | no | `battery` | Capacità in kWh | +| `minsoc` | `float` | no | `battery` | Livello di carica minimo in % come impostato sul sistema di accumulo (predefinito `0`) | +| `maxsoc` | `float` | no | `battery` | Livello di carica massimo in % come impostato sul sistema di accumulo (predefinito `100`) | +| `powers` | `[float,float,float]` | no | tutti | Potenze di fase in W. Per riconoscere il segno di correnti senza segno. | +| `currents` | `[float,float,float]` | no | tutti | Correnti di fase in A. Per riconoscere le fasi attive. | +| `voltages` | `[float,float,float]` | no | tutti | Tensioni di fase in V. Per riconoscere il tipo di collegamento (1p/3p). | ### Segni e direzioni \{#signs-and-directions\} @@ -138,7 +140,7 @@ Le letture reali del contatore forniscono statistiche a lungo termine più preci | Attributo | Tipo | Obbligatorio | Contesto | Descrizione | | ------------- | ----- | ------------ | --------- | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| `limitsoc` | `int` | no | `battery` | Imposta l’obiettivo di carica della batteria in %. L’obiettivo di carica viene calcolato dai valori configurati di `MinSoc` e `MaxSoc` e dal livello di carica attuale (attributo `soc`). | +| `limitsoc` | `int` | no | `battery` | Imposta l’obiettivo di carica della batteria in %. L’obiettivo di carica viene calcolato dai valori configurati di `minsoc` e `maxsoc` e dal livello di carica attuale (attributo `soc`). | | `curtail` | `int` | no | `pv` | Imposta il limite di immissione in rete in % della potenza nominale di produzione (da 0 a 100, `100` = nessun limite). Solo insieme a `curtailed`. Vedi [Dispositivo limitatore](#curtailer). | | `batterymode` | `int` | no | `battery` | Imposta direttamente la modalità di controllo della batteria. Le modalità sono elencate sotto. | diff --git a/src/content/docs/nl/reference/configuration/meters.md b/src/content/docs/nl/reference/configuration/meters.md index 827a1ec3af..643f4963a4 100644 --- a/src/content/docs/nl/reference/configuration/meters.md +++ b/src/content/docs/nl/reference/configuration/meters.md @@ -3,7 +3,7 @@ title: "meters" description: "Zo definieert u in evcc.yaml meters voor net, zonne-energie, thuisbatterij en verbruikers, en welke tekenconventie en metertypes daarbij gelden." sidebar: order: 5 -translatedFrom: "469542e8d8c5" +translatedFrom: "a65770242fcb" --- De lijst _meters_ (meetapparaten) bevat de apparaten in huis die vermogen en energieverbruik, de productie van zonne-energie of het gebruik van de thuisbatterij kunnen meten. Een `meter` definieert een meetpunt voor energie en kan een fysiek apparaat zijn (bijv. een meter op het netaansluitpunt), een omvormer van het zonnepanelensysteem (AC of DC bij hybride omvormers) of een batterijomvormer. @@ -374,9 +374,11 @@ Generieke implementatie waarbij de afzonderlijke waarden via [plugins](/nl/user- returnenergy: # Energie in omgekeerde richting (kWh) source: # Plugintype ... - soc: # Laadniveau batterij (%) + soc: # Laadniveau (%) source: # Plugintype ... + minsoc: 10 # Minimaal laadniveau (%) + maxsoc: 90 # Maximaal laadniveau (%) capacity: # Optionele batterijcapaciteit (kWh) currents: # Stroom (A) per fase - source: # Plugintype fase 1 @@ -457,13 +459,35 @@ Plugindefinitie die het laadniveau van de batterij in procent (%) levert. **Voorbeeld**: ```yaml - soc: ... # Laadniveau batterij (%) + soc: ... # Laadniveau (%) source: # Plugintype ... ``` --- +#### `minsoc` en `maxsoc` + +Onder- en bovengrens van het laadniveau van de batterij in procent, zoals ingesteld op het batterijsysteem. +Beide gelden alleen voor batterijen, d.w.z. samen met `soc`. +De [optimizer](/nl/features/optimizer) houdt het geplande laadniveau binnen deze grenzen. +Het laden van de batterij vanuit het net stopt bij `maxsoc`, en het ontladen naar het net stopt bij `minsoc`. +Met [`limitsoc`](/nl/user-defined-devices#meter-write-attributes) worden de [batterijmodi](/nl/user-defined-devices#battery-modes) via deze grenzen ingesteld: `normal` schrijft `minsoc`, `charge` schrijft `maxsoc` en `holddischarge` schrijft het actuele laadniveau, minimaal `minsoc`. +De standaardwaarden zijn `0` en `100`. +In plaats van een vaste waarde kan elke [float-plugin](/nl/reference/plugins) de grenzen uit het apparaat uitlezen. +De plugin wordt bij elke cyclus uitgelezen, en bij een mislukte uitlezing blijft de laatste waarde behouden. + +**Voorbeeld**: + +```yaml + minsoc: 10 # Minimaal laadniveau (%) + maxsoc: # uitlezen uit het apparaat in plaats van een vaste waarde + source: modbus + ... +``` + +--- + #### `capacity` Batterijcapaciteit in kWh. diff --git a/src/content/docs/nl/user-defined-devices.mdx b/src/content/docs/nl/user-defined-devices.mdx index 3acee4f73b..39b8b76811 100644 --- a/src/content/docs/nl/user-defined-devices.mdx +++ b/src/content/docs/nl/user-defined-devices.mdx @@ -3,7 +3,7 @@ title: Gebruikersgedefinieerde apparaten description: "Toont hoe u een lader, meter, voertuig of verwarmingstoestel zonder ingebouwde template koppelt door uitlezen en aansturen zelf via HTTP, MQTT of Modbus in te stellen." tableOfContents: maxHeadingLevel: 4 -translatedFrom: "161eb222a89c" +translatedFrom: "4b285bdf874c" --- import { Tabs, TabItem } from "@astrojs/starlight/components"; @@ -109,6 +109,8 @@ Gebruik voor de omzetting de [leespijplijnen](/nl/reference/plugins#reading). | `curtailed` | `int` | nee | `pv` | Actuele terugleveringslimiet in % (0 tot 100). Alleen samen met `curtail`. | | `soc` | `int` | nee | `battery` | Laadniveau in % | | `capacity` | `float` | nee | `battery` | Capaciteit in kWh | +| `minsoc` | `float` | nee | `battery` | Minimaal laadniveau in % zoals ingesteld op het batterijsysteem (standaard `0`) | +| `maxsoc` | `float` | nee | `battery` | Maximaal laadniveau in % zoals ingesteld op het batterijsysteem (standaard `100`) | | `powers` | `[float,float,float]` | nee | alle | Fasevermogens in W. Hiermee wordt de richting bepaald als de stromen zonder teken worden geleverd. | | `currents` | `[float,float,float]` | nee | alle | Fasestromen in A. Voor het herkennen van actieve fasen. | | `voltages` | `[float,float,float]` | nee | alle | Fasespanningen in V. Voor het herkennen van de aansluiting (1p/3p). | @@ -138,7 +140,7 @@ Echte meterstanden geven nauwkeurigere statistieken op de lange termijn. | Attribuut | Type | Verplicht | Context | Beschrijving | | ------------- | ----- | --------- | --------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | -| `limitsoc` | `int` | nee | `battery` | Laaddoel voor de batterij in % instellen. Het laaddoel wordt berekend uit de geconfigureerde `MinSoc`, `MaxSoc` en het actuele laadniveau (attribuut `soc`). | +| `limitsoc` | `int` | nee | `battery` | Laaddoel voor de batterij in % instellen. Het laaddoel wordt berekend uit de geconfigureerde `minsoc`, `maxsoc` en het actuele laadniveau (attribuut `soc`). | | `curtail` | `int` | nee | `pv` | Terugleveringslimiet in % van het nominale opwekvermogen instellen (0 tot 100, `100` = geen limiet). Alleen samen met `curtailed`. Zie [Opwekbegrenzingsapparaat](#curtailer). | | `batterymode` | `int` | nee | `battery` | De regelmodus van de batterij direct instellen. De modi staan hieronder. |