diff --git a/packages/modules/devices/mtec/mtec/bat.py b/packages/modules/devices/mtec/mtec/bat.py index dc47349b02..4f4354db63 100644 --- a/packages/modules/devices/mtec/mtec/bat.py +++ b/packages/modules/devices/mtec/mtec/bat.py @@ -1,6 +1,6 @@ #!/usr/bin/env python3 import logging -from typing import TypedDict, Any +from typing import TypedDict, Any, Optional from modules.common.abstract_device import AbstractBat from modules.common.component_state import BatState @@ -56,5 +56,28 @@ def update(self) -> None: ) self.store.set(bat_state) + def set_power_limit(self, power_limit: Optional[int]) -> None: + modbus_id = self.component_config.configuration.modbus_id + if power_limit is None: + log.debug("Keine Batteriesteuerung, Selbstregelung durch Speicher") + if self.last_mode is not None: + self.__tcp_client.write_register(50000, 257, data_type=ModbusDataType.UINT_16, unit=modbus_id) + self.last_mode = None + elif power_limit <= 0: + log.debug("Aktive Batteriesteuerung. Batterie wird auf Stop gesetzt und nicht entladen") + if self.last_mode != 'stop': + self.__tcp_client.write_register(50000, 258, data_type=ModbusDataType.UINT_16, unit=modbus_id) + self.last_mode = 'stop' + elif power_limit > 0: + log.debug(f"Aktive Batteriesteuerung M-Tec:" + f"Speicher soll mit {power_limit} W geladen werden. " + "kann aber nur mit maximaler Leistung laden") + if self.last_mode != 'charge': + self.__tcp_client.write_register(50000, 259, data_type=ModbusDataType.UINT_16, unit=modbus_id) + self.last_mode = 'charge' + + def power_limit_controllable(self) -> bool: + return True + component_descriptor = ComponentDescriptor(configuration_factory=MTecBatSetup)