Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
4 changes: 2 additions & 2 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -36,10 +36,10 @@ Changelog
* Allow `equilibration_time` to be a list of times, one for each lambda window, e.g. `--equilibration-time 0ps 100ps 100ps 0ps` on the command line. Windows with a time of zero are not equilibrated. A single time is still used for every window [#265](https://github.com/OpenBioSim/somd2/pull/265).
* Pass `opencl_platform_index` to the GCMC sampler, so that GCMC runs on the same OpenCL device as the dynamics when there are multiple OpenCL platforms [#266](https://github.com/OpenBioSim/somd2/pull/266).
* Fixed energy trajectory times for ABFE bound legs without a Boresch restraint being offset by up to the `restraint_search_time`, since production started from the time of the restraint search frame rather than the input system [#268](https://github.com/OpenBioSim/somd2/pull/268).
* Raise an error when a `perturbed_system` with a different periodic box from the reference system is used for GCMC in the NVT ensemble, since every replica must share the same box. GCMC in the osmotic ensemble, with a pressure set, is unaffected [#271](https://github.com/OpenBioSim/somd2/pull/271).
* Raise an error when a `perturbed_system` with a different periodic box from the reference system is used for GCMC in the NVT ensemble, since every replica must share the same box [#271](https://github.com/OpenBioSim/somd2/pull/271).
* Add a `chain_equilibration` option for replica exchange, which speeds up setup by starting each replica from a neighbour that has already been set up. Replicas in the first parallel batch, which is spread across lambda, are minimised and equilibrated from the input system. The rest skip minimisation and are equilibrated for `chain_equilibration_scale` times the `equilibration_time`, which defaults to a quarter [#273](https://github.com/OpenBioSim/somd2/pull/273).
* Pass `beutler_alpha` to the GCMC sampler, which otherwise used its own default for the Beutler soft-core form [#275](https://github.com/OpenBioSim/somd2/pull/275).
* Default `gcmc_bulk_sampling_probability` to "auto", which uses 0.1 in the NVT ensemble and 0 when a pressure is set, since the solvent's chemical potential barely depends on the number of waters, so whole-box moves under a barostat let that number drift. A warning is logged when whole-box moves are used with a pressure. On restart, "auto" keeps the value of the last run, and other changes are refused [#278](https://github.com/OpenBioSim/somd2/pull/278).
* Run GCMC simulations in the NVT ensemble, ignoring the pressure, since the osmotic ensemble isn't valid for GCMC of solvent water: the number of waters is barely fixed, so it drifts. GCMC runs started with a pressure can't be restarted [#281](https://github.com/OpenBioSim/somd2/pull/281).

[2026.2.0](https://github.com/openbiosim/somd2/compare/2026.1.0...2026.2.0) - Sep 2026
--------------------------------------------------------------------------------------
Expand Down
68 changes: 12 additions & 56 deletions src/somd2/config/_config.py
Original file line number Diff line number Diff line change
Expand Up @@ -76,13 +76,12 @@ class Config:
"log_level": [level.lower() for level in _logger._core.levels],
"softcore_form": ["auto", "zacharias", "taylor", "beutler"],
"precision": ["single", "mixed", "double"],
"gcmc_bulk_sampling_probability": ["auto"],
}

# Options that advertise a set of choices, but which also accept other
# forms, e.g. the path to a stream file. These are validated by the setter,
# rather than by argparse.
_open_choices = ["lambda_schedule", "gcmc_bulk_sampling_probability"]
_open_choices = ["lambda_schedule"]

# A dictionary of nargs for the various options.
_nargs = {
Expand Down Expand Up @@ -217,7 +216,7 @@ def __init__(
gcmc_standard_volume="30.543 A^3",
gcmc_num_waters=20,
gcmc_radius="4 A",
gcmc_bulk_sampling_probability="auto",
gcmc_bulk_sampling_probability=0.1,
gcmc_tolerance=0.0,
gcmc_batch_size=1000,
gcmc_num_attempts=10000,
Expand Down Expand Up @@ -265,7 +264,8 @@ def __init__(

pressure: str
Simulation pressure. (Simulations will run in the NVT ensemble unless
a pressure is specified.)
a pressure is specified. GCMC simulations always run in the NVT
ensemble, so the pressure is ignored.)

surface_tension: str
Surface tension to use for NPT simulations with a membrane barostat.
Expand Down Expand Up @@ -603,6 +603,7 @@ def __init__(

gcmc: bool
Whether to perform Grand Canonical Monte Carlo (GCMC) water insertions/deletions.
GCMC simulations always run in the NVT ensemble.

gcmc_frequency: str
Frequency at which to attempt GCMC moves. If None, then this will be set to the
Expand All @@ -629,14 +630,11 @@ def __init__(
gcmc_radius: str
The radius of the GCMC sphere.

gcmc_bulk_sampling_probability: float, str
gcmc_bulk_sampling_probability: float
The probability of performing bulk GCMC moves, i.e. within the entire simulation
box rather than the GCMC sphere. These maintain the bulk density in the NVT
ensemble, i.e. acting as a barostat, so aren't needed when a pressure is set.
The default, "auto", uses 0.1 when 'pressure' is None and 0 otherwise. On
restart, "auto" keeps the value of the last run, and other values can't
change. (This option has no effect when 'gcmc_selection=None', where every
move is a bulk move.)
box rather than the GCMC sphere. These can be used to maintain a constant bulk
density, i.e. acting as a barostat. (This option has no affect when
'gcmc_selection=None'.)

gcmc_tolerance: float
The tolerance for the GCMC acceptance probability, i.e. the minimum probability
Expand Down Expand Up @@ -2678,58 +2676,16 @@ def gcmc_radius(self, gcmc_radius):

@property
def gcmc_bulk_sampling_probability(self):
# Resolved on read, so that "auto" follows later changes to the pressure.
return self._resolve_bulk_sampling_probability(
self._gcmc_bulk_sampling_probability, getattr(self, "_pressure", None)
)

@staticmethod
def _is_auto(value):
"""
Whether an option value is "auto", in any case.
"""
return isinstance(value, str) and value.strip().lower() == "auto"

@staticmethod
def _unwrap(value):
"""
Convert a value from a config stored as a Sire property, e.g. in a
checkpoint file, to a Python value. Units are converted to strings.
"""
from sire.units import GeneralUnit as _GeneralUnit

if isinstance(value, _GeneralUnit):
return str(value)
try:
return value.value()
except AttributeError:
return value

@staticmethod
def _resolve_bulk_sampling_probability(probability, pressure):
"""
Resolve a GCMC bulk sampling probability, which may be "auto", for the
given pressure. Bulk moves act as a barostat, so aren't used with one.
"""
probability = Config._unwrap(probability)
if Config._is_auto(probability):
# A stored config records no pressure as None or False.
return 0.1 if not Config._unwrap(pressure) else 0.0
return float(probability)
return self._gcmc_bulk_sampling_probability

@gcmc_bulk_sampling_probability.setter
def gcmc_bulk_sampling_probability(self, gcmc_bulk_sampling_probability):
if self._is_auto(gcmc_bulk_sampling_probability):
self._gcmc_bulk_sampling_probability = "auto"
return
if not isinstance(gcmc_bulk_sampling_probability, float):
try:
gcmc_bulk_sampling_probability = float(gcmc_bulk_sampling_probability)
except Exception:
raise ValueError(
"'gcmc_bulk_sampling_probability' must be a float or 'auto'"
)
if not 0.0 <= gcmc_bulk_sampling_probability <= 1.0:
raise ValueError("'gcmc_bulk_sampling_probability' must be a float")
if gcmc_bulk_sampling_probability < 0.0 or gcmc_bulk_sampling_probability > 1.0:
raise ValueError(
"'gcmc_bulk_sampling_probability' must be between 0.0 and 1.0"
)
Expand Down
98 changes: 18 additions & 80 deletions src/somd2/runner/_base.py
Original file line number Diff line number Diff line change
Expand Up @@ -77,7 +77,6 @@ def __init__(self, system, config):
self._set_terminal_groups()

self._prepare_output_and_restart()
self._check_gcmc_bulk_moves()
self._finalise_systems()
self._set_dynamics_kwargs()
self._limit_sire_threads()
Expand Down Expand Up @@ -131,6 +130,14 @@ def _set_config(self, config):
# user's final choice of output directory is known.
self._config._setup_output_directory()

# GCMC of solvent water is only well defined at constant volume.
if self._config.gcmc and self._config.pressure is not None:
_logger.info(
"GCMC simulations are run in the NVT ensemble, so the pressure is "
"ignored."
)
self._config.pressure = None

# Progress is reported through the logger, so silence Sire's progress
# bars. This also lets Sire run dynamics in longer blocks, since the
# blocks only exist to update the bar.
Expand Down Expand Up @@ -165,8 +172,8 @@ def _check_inputs(self):
_logger.error(msg)
raise ValueError(msg)

# GCMC in the NVT ensemble needs every replica to share the same box.
if self._config.gcmc and self._config.pressure is None:
# GCMC runs in the NVT ensemble, so every replica must share the same box.
if self._config.gcmc:
space = self._system.space()
pert_space = self._config.perturbed_system.space()
vectors = self._box_vectors(space)
Expand All @@ -177,10 +184,9 @@ def _check_inputs(self):
):
msg = (
f"The periodic box of 'perturbed_system' ({pert_space}) does not "
f"match that of the 'system' ({space}). GCMC in the NVT ensemble "
"needs both end states to share the same box. Rescale the perturbed "
"system to the reference box, or set a pressure to run in the "
"osmotic ensemble."
f"match that of the 'system' ({space}). GCMC runs in the NVT "
"ensemble, so both end states must share the same box. Rescale "
"the perturbed system to the reference box."
)
_logger.error(msg)
raise ValueError(msg)
Expand Down Expand Up @@ -1066,29 +1072,6 @@ def _check_gcmc(self):
# Store the excess chemcical potential value.
self._mu_ex = self._config.gcmc_excess_chemical_potential.value()

def _check_gcmc_bulk_moves(self):
"""
Warn when whole-box GCMC moves are used with a pressure set. This runs
after the restart check, which can change the bulk sampling probability.
"""
if not self._config.gcmc or self._config.pressure is None:
return

if self._config.gcmc_selection is None:
_logger.warning(
"Every GCMC move samples the whole box when 'gcmc_selection' "
"is None. With a pressure set, the number of bulk waters can "
"drift. Set a 'gcmc_selection', or 'pressure=None' to run in "
"the NVT ensemble."
)
elif self._config.gcmc_bulk_sampling_probability > 0.0:
_logger.warning(
"Bulk GCMC moves are used with a pressure set, so the number "
"of bulk waters can drift. Set "
"'gcmc_bulk_sampling_probability=0', or 'pressure=None' to "
"run in the NVT ensemble."
)

def _set_terminal_groups(self):
"""
Validate the terminal flip options and detect the terminal ring groups,
Expand Down Expand Up @@ -1241,7 +1224,6 @@ def _set_dynamics_kwargs(self):
"lambda_schedule": self._config.lambda_schedule,
"no_logger": True,
"num_ghost_waters": self._config.gcmc_num_waters,
"pressure": self._config.pressure,
"overwrite": self._config.overwrite,
"radius": str(self._config.gcmc_radius),
"reference": self._config.gcmc_selection,
Expand Down Expand Up @@ -2407,31 +2389,6 @@ def _check_restart(self):

return True, systems

def _inherit_bulk_sampling_probability(self, config):
"""
When the GCMC bulk sampling probability is "auto", keep the value of the
last run, so that the run stays in one ensemble.

Parameters
----------

config: dict
The current config dictionary, which is updated to match.
"""
last = _Config._unwrap(self._last_config.get("gcmc_bulk_sampling_probability"))
if last is None or _Config._is_auto(last):
return
if not _Config._is_auto(self._config._gcmc_bulk_sampling_probability):
return

value = float(last)
self._config.gcmc_bulk_sampling_probability = value
config["gcmc_bulk_sampling_probability"] = value
if self._config.gcmc:
_logger.info(
f"Using 'gcmc_bulk_sampling_probability={value}' from the last run."
)

@staticmethod
def _compare_configs(config1, config2):
"""
Expand Down Expand Up @@ -2464,29 +2421,6 @@ def _compare_configs(config1, config2):
if v1 == v2:
continue

# Compare the resolved values, so that "auto" matches the
# explicit value it stands for. A changed pressure is reported
# by its own check instead.
if key == "gcmc_bulk_sampling_probability":
if (_Config._unwrap(config1.get("pressure")) or None) != (
_Config._unwrap(config2.get("pressure")) or None
):
continue
p1 = _Config._resolve_bulk_sampling_probability(
v1, config1.get("pressure")
)
p2 = _Config._resolve_bulk_sampling_probability(
v2, config2.get("pressure")
)
if not _isclose(p1, p2):
raise ValueError(
f"{key} has changed since the last run ({p1} vs {p2}). "
"This is not allowed when using the restart option. "
f"Set gcmc_bulk_sampling_probability={p1} to continue "
"the run."
)
continue

# Custom lambda schedules are stored as a hexademical string of
# serialised object. We need to deserialise them before comparison.
if key == "lambda_schedule":
Expand Down Expand Up @@ -2577,6 +2511,11 @@ def _compare_configs(config1, config2):
)
if key == "softcore_form":
msg += f" Set softcore_form='{v1}' to continue the run."
elif key == "pressure" and config2.get("gcmc") is True:
msg += (
" GCMC simulations are run in the NVT ensemble, so a run "
"started with a pressure can't be continued."
)
raise ValueError(msg)

def _verify_restart_config(self):
Expand Down Expand Up @@ -2628,7 +2567,6 @@ def get_last_config(output_directory):
"Cannot validate restart config without a config.yaml file."
)

self._inherit_bulk_sampling_probability(config)
self._compare_configs(self._last_config, config)

# Adaptive replica exchange derives each window's sample count from its
Expand Down
Loading
Loading