5 changes: 3 additions & 2 deletions CLAUDE.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,8 @@ Readout is a companion app for the EEVblog 121GW multimeter over Bluetooth LE, b
- `Readout.Linux/`: the Linux head (see Linux below). `BlueZ/` is the meter connection over BlueZ; the other files fill gaps in the GTK backend.
- `Readout.Tests/`: xUnit v3 tests for the core and the MCP server (end to end with the SDK's client), plus the Linux head's `BlueZNames` and `RecentRssi`, compiled in as linked files (they must stay free of D-Bus and GTK).
- `docs/PROTOCOL.md`: the packet format. Read it before touching `Protocol/` or `Display/`.
- `Readout.Core/Fs9721/`: the decoder for Fortune FS9721_LP3 meters (a DIY Bluetooth bridge on cheap meters), written from Fortune's datasheet. Readings go through the same log, graphs and MCP tools. `firmware/fs9721-bridge/` is the ESP32 bridge (PlatformIO, NimBLE) that forwards the chip's bytes over BLE; its UUIDs and name must match `Protocol/BridgeBluetooth` (a test checks). `docs/FS9721.md` has the frame format and the plan. Tests use real frames from `Readout.Tests/TestData/fs9721-890g.txt`.
- `Readout.Core/Fs9721/`: the decoder for Fortune FS9721_LP3 meters (a DIY Bluetooth bridge on cheap meters), written from Fortune's datasheet. Readings go through the same log, graphs and MCP tools. `firmware/readout-bridge/` is the ESP32 bridge (PlatformIO, NimBLE) that forwards the chip's bytes over BLE, with a chip profile picked at build time (`fs9721-*` and `dso150-*` envs); its UUIDs, name and MTU must match `Protocol/BridgeBluetooth` (a test checks). `docs/FS9721.md` has the frame format and the plan. Tests use real frames from `Readout.Tests/TestData/fs9721-890g.txt`.
- `Readout.Core/Dso150/`: the JYE Tech DSO150 oscilloscope running DSOShell (the user's open firmware for it, in its own repo: the plan is its `docs/READOUT.md`, the wire protocol its `docs/PROTOCOL.md`). Through the bridge's two-way `dso150-*` builds: 115200 8N1, and the app writes commands to the bridge's RX characteristic with `IMeterConnection.SendAsync` (`MeterSession.SendAsync`). `Dso150Driver` is a placeholder that makes no readings yet; `BleMeterConnection` logs what a DSO150 sends (`dso150 rx ...`) until it decodes them. Bridges get MTU 247 (`RequestMtuAsync`; only Android needs the request).

The protocol is ported from the official EEVblog app's `PrivatePostRelease` branch (https://gitlab.com/eevblog/app-121gw, MIT, David Ledger), and matches EEVblog's "Revised Packet Format Blob V2" document. Its `master` branch has an obsolete 52-character text parser; ignore it. Keep the David Ledger credit in THIRD_PARTY_NOTICES.md and the About page.

Expand All @@ -38,7 +39,7 @@ dotnet build Readout -f net10.0-android
git tag v1.2.0 && git push origin v1.2.0 # release.yml: every store + a GitHub release (docs/STORE-CI.md)
dotnet build Readout.Linux # the Linux head (plain net10.0, builds on the Mac too, no workload)
./publish-linux.sh x64 arm64 # self-contained Readout-linux-<arch>.tar.gz in Readout.Linux/bin/publish/
./deploy-esp.sh # build and flash the FS9721 bridge to an ESP32 on USB (--log follows it; other builds: esp32dev-vdd, esp32c3…)
./deploy-esp.sh # build and flash the bridge to an ESP32 on USB (--log follows it; default fs9721-esp32dev, others: fs9721-esp32c3, dso150-esp32dev…)
```

## Things to know
Expand Down
10 changes: 9 additions & 1 deletion Readout.Core/Connection/IMeterConnection.cs
Original file line number Diff line number Diff line change
Expand Up @@ -53,6 +53,14 @@ public interface IMeterConnection

Task DisconnectAsync();

/// <summary>Presses one of the meter's buttons remotely.</summary>
/// <summary>Presses one of the meter's buttons remotely (the 121GW).</summary>
Task SendKeyAsync(MeterKey key, bool longPress = false, CancellationToken ct = default);

/// <summary>
/// Sends bytes to the meter as they are: a two-way bridge writes them to its chip's serial
/// input (<see cref="BridgeBluetooth.RxCharacteristicUuid"/>). Does nothing while not
/// connected.
/// </summary>
/// <exception cref="NotSupportedException">The connected meter takes no bytes (a 121GW, an FS9721 bridge).</exception>
Task SendAsync(ReadOnlyMemory<byte> data, CancellationToken ct = default);
}
5 changes: 4 additions & 1 deletion Readout.Core/Connection/IMeterDriver.cs
Original file line number Diff line number Diff line change
@@ -1,4 +1,5 @@
using Readout.Core.Display;
using Readout.Core.Dso150;
using Readout.Core.Fs9721;

namespace Readout.Core.Connection;
Expand Down Expand Up @@ -28,7 +29,9 @@ public static class MeterDrivers
{
public static IMeterDriver For(MeterModel model) => model switch
{
MeterModel.Eevblog121Gw => new Eevblog121GwDriver(),
MeterModel.Fs9721 => new Fs9721Driver(),
_ => new Eevblog121GwDriver(),
MeterModel.Dso150 => new Dso150Driver(),
_ => throw new ArgumentOutOfRangeException(nameof(model), model, "No driver for this meter."),
};
}
10 changes: 9 additions & 1 deletion Readout.Core/Connection/MeterCapabilities.cs
Original file line number Diff line number Diff line change
Expand Up @@ -15,9 +15,17 @@ public sealed record MeterCapabilities(bool RemoteKeys, bool ClockSync, bool Sub
/// <summary>An FS9721 through a bridge: it only sends, 3¾ digits, nothing else.</summary>
public static readonly MeterCapabilities Fs9721 = new(RemoteKeys: false, ClockSync: false, SubDisplay: false, BarGraph: false, Digits: 4);

/// <summary>
/// A DSO150 oscilloscope through a bridge: no buttons to press (it takes commands instead),
/// no clock, no LCD extras. Its measurements come from an 8-bit ADC, so 4 digits is plenty.
/// </summary>
public static readonly MeterCapabilities Dso150 = new(RemoteKeys: false, ClockSync: false, SubDisplay: false, BarGraph: false, Digits: 4);

public static MeterCapabilities For(MeterModel model) => model switch
{
MeterModel.Eevblog121Gw => Eevblog121Gw,
MeterModel.Fs9721 => Fs9721,
_ => Eevblog121Gw,
MeterModel.Dso150 => Dso150,
_ => throw new ArgumentOutOfRangeException(nameof(model), model, "No capabilities for this meter."),
};
}
4 changes: 4 additions & 0 deletions Readout.Core/Connection/MeterSession.cs
Original file line number Diff line number Diff line change
Expand Up @@ -190,6 +190,10 @@ public Task SendKeyAsync(MeterKey key, bool longPress = false, CancellationToken
return Active.SendKeyAsync(key, longPress, ct);
}

/// <summary>Sends bytes to the connected meter as they are (a DSO150's commands); see <see cref="IMeterConnection.SendAsync"/>.</summary>
public Task SendAsync(ReadOnlyMemory<byte> data, CancellationToken ct = default) =>
Active.State == ConnectionState.Connected ? Active.SendAsync(data, ct) : Task.CompletedTask;

private async Task LeaveDemoAsync()
{
if (!IsDemo) return;
Expand Down
14 changes: 14 additions & 0 deletions Readout.Core/Connection/SimulatedMeterConnection.cs
Original file line number Diff line number Diff line change
Expand Up @@ -29,6 +29,9 @@ public sealed class SimulatedMeterConnection : IMeterConnection, IDisposable
/// <summary>A key press reached the simulated meter (for tests).</summary>
public event EventHandler<MeterKey>? KeySent;

/// <summary>Bytes sent with <see cref="SendAsync"/> reached the simulated meter (for tests).</summary>
public event EventHandler<ReadOnlyMemory<byte>>? DataSent;

public ConnectionState State { get; private set; }
public DiscoveredMeter? Meter { get; private set; }

Expand Down Expand Up @@ -99,6 +102,17 @@ public Task SendKeyAsync(MeterKey key, bool longPress = false, CancellationToken
return Task.CompletedTask;
}

/// <summary>
/// The demo meter takes the bytes and ignores them: it plays a 121GW, which answers only key
/// presses. A simulated DSO150 will answer them.
/// </summary>
public Task SendAsync(ReadOnlyMemory<byte> data, CancellationToken ct = default)
{
if (State == ConnectionState.Connected && !data.IsEmpty)
DataSent?.Invoke(this, data.ToArray());
return Task.CompletedTask;
}

/// <summary>Makes the next packet arrive now (tests drive the meter with this instead of waiting).</summary>
public void Tick()
{
Expand Down
5 changes: 5 additions & 0 deletions Readout.Core/Display/MeterReading.cs
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,11 @@ public enum MeterModel
Eevblog121Gw,
/// <summary>A meter built on Fortune's FS9721_LP3 chip, through a DIY Bluetooth bridge.</summary>
Fs9721,
/// <summary>
/// A JYE Tech DSO150 pocket oscilloscope running DSOShell, through the two-way bridge. Its
/// protocol is text lines and binary waveform blocks (DSOShell's docs/PROTOCOL.md).
/// </summary>
Dso150,
}

/// <summary>Everything the meter's LCD shows for one packet or frame, decoded for display and logging.</summary>
Expand Down
25 changes: 25 additions & 0 deletions Readout.Core/Dso150/Dso150Driver.cs
Original file line number Diff line number Diff line change
@@ -0,0 +1,25 @@
using Readout.Core.Connection;
using Readout.Core.Display;

namespace Readout.Core.Dso150;

/// <summary>
/// A DSO150 oscilloscope running DSOShell, through the two-way bridge. For now it only takes the
/// bytes and makes no readings: decoding <c>MEAS</c> records into readings (and waveforms after
/// that) is the next step. It exists so a DSO150 gets its own driver, never the 121GW's.
/// </summary>
public sealed class Dso150Driver : IMeterDriver
{
public MeterModel Model => MeterModel.Dso150;

/// <summary>Bytes received since the last <see cref="Reset"/>.</summary>
public long BytesReceived { get; private set; }

public IReadOnlyList<DriverReading> Receive(ReadOnlySpan<byte> data, DateTimeOffset now)
{
BytesReceived += data.Length;
return [];
}

public void Reset() => BytesReceived = 0;
}
24 changes: 18 additions & 6 deletions Readout.Core/Protocol/BridgeBluetooth.cs
Original file line number Diff line number Diff line change
Expand Up @@ -3,9 +3,10 @@
namespace Readout.Core.Protocol;

/// <summary>
/// How a Readout bridge shows up over Bluetooth LE: an ESP32 that reads a meter chip's serial
/// output and forwards the bytes as they come (firmware in <c>firmware/fs9721-bridge</c>).
/// The app frames and decodes them, so supporting another chip needs no firmware change.
/// How a Readout bridge shows up over Bluetooth LE: an ESP32 wired to a meter chip's serial port
/// that forwards the bytes as they come (firmware in <c>firmware/readout-bridge</c>). The app
/// frames and decodes them, so supporting another chip needs no change to what the bridge does
/// with the bytes. Two-way bridges (the DSO150's) also pass what the app writes to the chip.
/// </summary>
public static class BridgeBluetooth
{
Expand All @@ -16,11 +17,17 @@ public static class BridgeBluetooth
public static readonly Guid DataCharacteristicUuid = Guid.Parse("4D19A30C-94D7-404E-A69D-B513188F13DC");

/// <summary>
/// Readable text, one <c>key=value</c> per line: <c>chip</c> (FS9721), <c>symbols</c> (the
/// meter's maker-chosen symbols, comma separated) and <c>firmware</c>.
/// Readable text, one <c>key=value</c> per line: <c>chip</c> (FS9721, DSO150), <c>symbols</c>
/// (an FS9721 meter's maker-chosen symbols, comma separated), <c>baud</c> and <c>firmware</c>.
/// </summary>
public static readonly Guid InfoCharacteristicUuid = Guid.Parse("6DAA6868-77CD-4539-8B02-6A82B3C6BC0C");

/// <summary>
/// Writable (with or without response) on two-way bridges only: the bytes go out the chip's
/// serial input unchanged. Receive-only bridges (FS9721) don't have it.
/// </summary>
public static readonly Guid RxCharacteristicUuid = Guid.Parse("3065C3CA-B78A-4B98-96B6-280CF0784EC4");

/// <summary>Bridges advertise as "Readout &lt;chip&gt; &lt;id&gt;", for example "Readout FS9721 A1B2".</summary>
public const string NamePrefix = "Readout ";

Expand All @@ -30,6 +37,11 @@ public static class BridgeBluetooth
if (string.IsNullOrEmpty(name) || !name.StartsWith(NamePrefix, StringComparison.OrdinalIgnoreCase))
return null;
var chip = name[NamePrefix.Length..].Split(' ', 2)[0];
return chip.Equals("FS9721", StringComparison.OrdinalIgnoreCase) ? MeterModel.Fs9721 : null;
if (chip.Equals("FS9721", StringComparison.OrdinalIgnoreCase)) return MeterModel.Fs9721;
if (chip.Equals("DSO150", StringComparison.OrdinalIgnoreCase)) return MeterModel.Dso150;
return null;
}

/// <summary>The ATT MTU the app and the bridge ask for: 244-byte notifications instead of 20.</summary>
public const int PreferredMtu = 247;
}
36 changes: 33 additions & 3 deletions Readout.Linux/BlueZ/BlueZMeterConnection.cs
Original file line number Diff line number Diff line change
Expand Up @@ -49,6 +49,10 @@ internal sealed class BlueZMeterConnection : IMeterConnection, IDisposable
private string? _devicePath;
private string? _dataPath;
private string _writeType = "request";
// A two-way bridge's RX characteristic (the DSO150's), where SendAsync writes.
private string? _rxPath;
private readonly SemaphoreSlim _writeGate = new(1, 1);
private const int MaxWriteLength = 512;

public BlueZMeterConnection(BlueZBus bus, ILogger<BlueZMeterConnection> logger)
{
Expand Down Expand Up @@ -231,7 +235,8 @@ private async Task ConnectCoreAsync(DiscoveredMeter meter, CancellationToken ct)
while (!await ServicesResolvedAsync(devicePath).ConfigureAwait(false))
await Task.Delay(100, ct).ConfigureAwait(false);

var data = BlueZNames.PickDataCharacteristic(await CharacteristicsAsync(devicePath).ConfigureAwait(false))
var characteristics = await CharacteristicsAsync(devicePath).ConfigureAwait(false);
var data = BlueZNames.PickDataCharacteristic(characteristics)
?? throw new InvalidOperationException("This device has no meter data characteristic.");
if (!BlueZNames.IsKnownDataCharacteristic(data.Uuid))
_logger.LogWarning("data characteristic not found by UUID, using {Uuid}", data.Uuid);
Expand All @@ -240,6 +245,7 @@ private async Task ConnectCoreAsync(DiscoveredMeter meter, CancellationToken ct)
{
_dataPath = data.Path;
_writeType = BlueZNames.WriteType(data.Flags);
_rxPath = BlueZNames.PickRxCharacteristic(characteristics)?.Path;
}
await _bus.CallAsync(data.Path, BlueZNames.GattCharacteristic1, "StartNotify").WaitAsync(ct).ConfigureAwait(false);

Expand Down Expand Up @@ -370,13 +376,37 @@ public async Task SendKeyAsync(MeterKey key, bool longPress = false, Cancellatio
await _bus.WriteValueAsync(dataPath, MeterCommands.KeyPress(key, longPress), writeType).WaitAsync(ct).ConfigureAwait(false);
}

public async Task SendAsync(ReadOnlyMemory<byte> data, CancellationToken ct = default)
{
string? rxPath;
lock (_gate) rxPath = _dataPath is null ? null : _rxPath ?? "";
if (rxPath is null || data.IsEmpty) return;
if (rxPath.Length == 0) throw new NotSupportedException($"{Meter?.Name ?? "This meter"} takes no data.");

// In order, one at a time. A write request longer than the MTU allows goes as a long
// write, which BlueZ splits up; one attribute holds at most 512 bytes.
await _writeGate.WaitAsync(ct).ConfigureAwait(false);
try
{
for (var offset = 0; offset < data.Length; offset += MaxWriteLength)
{
var chunk = data.Slice(offset, Math.Min(MaxWriteLength, data.Length - offset)).ToArray();
await _bus.WriteValueAsync(rxPath, chunk, "request").WaitAsync(ct).ConfigureAwait(false);
}
}
finally
{
_writeGate.Release();
}
}

private async Task CloseLinkAsync()
{
string? devicePath, dataPath;
lock (_gate)
{
(devicePath, dataPath) = (_devicePath, _dataPath);
_devicePath = _dataPath = null;
_devicePath = _dataPath = _rxPath = null;
}
_rssi.Clear();

Expand Down Expand Up @@ -461,7 +491,7 @@ private void OnDeviceChanged(string path, string address, Props changed, string[
private void OnLinkDropped()
{
_logger.LogWarning("link lost");
lock (_gate) _devicePath = _dataPath = null;
lock (_gate) _devicePath = _dataPath = _rxPath = null;
_rssi.Clear();
Meter = null;
SetState(ConnectionState.Disconnected);
Expand Down
4 changes: 4 additions & 0 deletions Readout.Linux/BlueZ/BlueZNames.cs
Original file line number Diff line number Diff line change
Expand Up @@ -93,6 +93,10 @@ public static bool IsLeOnly(string? addressType, byte[]? advertisingFlags) =>
!(Guid.TryParse(c.ServiceUuid, out var service) && MeterBluetooth.StandardServices.Contains(service)));
}

/// <summary>A two-way bridge's RX characteristic, where commands for its chip go; null on other meters.</summary>
public static GattCharacteristicInfo? PickRxCharacteristic(IEnumerable<GattCharacteristicInfo> characteristics) =>
characteristics.FirstOrDefault(c => Guid.TryParse(c.Uuid, out var id) && id == BridgeBluetooth.RxCharacteristicUuid);

/// <summary>
/// WriteValue's "type": a write request (acknowledged) when the characteristic takes one,
/// else a write command.
Expand Down
7 changes: 6 additions & 1 deletion Readout.Mcp/MeterTools.cs
Original file line number Diff line number Diff line change
Expand Up @@ -114,7 +114,12 @@ public Task<string> GetStatusAsync() => ui.InvokeAsync(() =>
return McpResultJson.Serialize(new StatusResult(
session.State.ToString(),
session.Meter?.Name,
session.Model == MeterModel.Fs9721 ? "FS9721" : "121GW",
session.Model switch
{
MeterModel.Fs9721 => "FS9721",
MeterModel.Dso150 => "DSO150",
_ => "121GW",
},
session.Capabilities.RemoteKeys,
session.IsDemo,
rssi,
Expand Down
20 changes: 20 additions & 0 deletions Readout.Tests/BlueZTests.cs
Original file line number Diff line number Diff line change
Expand Up @@ -54,6 +54,7 @@ public void MeterName_ComesFromTheNameOrAlias(string? name, string? alias, strin
[InlineData("121GW", MeterModel.Eevblog121Gw)]
[InlineData("Bluegiga", MeterModel.Eevblog121Gw)]
[InlineData("Readout FS9721 B1CC", MeterModel.Fs9721)]
[InlineData("Readout DSO150 B1CC", MeterModel.Dso150)]
public void Model_ComesFromTheName(string name, MeterModel model) =>
Assert.Equal(model, BlueZNames.ModelFromName(name));

Expand All @@ -69,6 +70,25 @@ public void BridgeDataCharacteristic_IsFoundByUuid()
Assert.Equal(Device + "/service0010/char0013", picked?.Path);
}

[Fact]
public void TwoWayBridge_RxCharacteristic_IsFoundByUuid()
{
GattCharacteristicInfo[] characteristics =
[
new(Device + "/service0010/char0011", BridgeBluetooth.ServiceUuid.ToString(), BridgeBluetooth.DataCharacteristicUuid.ToString(), ["notify"]),
new(Device + "/service0010/char0016", BridgeBluetooth.ServiceUuid.ToString(), BridgeBluetooth.RxCharacteristicUuid.ToString().ToUpperInvariant(), ["write", "write-without-response"]),
];

Assert.Equal(Device + "/service0010/char0016", BlueZNames.PickRxCharacteristic(characteristics)?.Path);
// Data is still the notifying one, not the writable one.
Assert.Equal(Device + "/service0010/char0011", BlueZNames.PickDataCharacteristic(characteristics)?.Path);
}

[Fact]
public void ReceiveOnlyBridge_HasNoRxCharacteristic() =>
Assert.Null(BlueZNames.PickRxCharacteristic(
[new(Device + "/service0010/char0013", BridgeBluetooth.ServiceUuid.ToString(), BridgeBluetooth.DataCharacteristicUuid.ToString(), ["notify"])]));

[Fact]
public void DataCharacteristic_IsFoundByUuid_InAnyCase()
{
Expand Down