@shteudguy

Copy link
Copy Markdown
Contributor

Why

The G-010S-A can reach its FALCON console without the U-Boot version banner expected by the Huawei web-root flow. With the UART console disabled (for example, asc0=3), only the early ROM messages may appear. Those messages do not establish that bootloader commands can be executed.

The documented Nokia boot transcript shows the bannerless case. A dedicated Nokia action gives users the correct console setup procedure and an actionable result for ROM-only output.

Changes

  • Add a Configure Nokia UART helper to the G-010S-A page.
  • Recognize the actual FALCON => prompt, including split chunks, and verify bidirectional communication with a fresh echo challenge.
  • Bound startup interruption and I/O; support cancellation and recovery from nonfatal FTDI stream errors.
  • Read the original asc0, bootdelay and preboot, offer a local JSON backup, and show the proposed changes before confirmation.
  • Recheck the console and settings after confirmation, preserve a positive boot delay, set asc0=0, and clear only recognized Nokia preboot values.
  • Verify changes before saveenv, require its success acknowledgement, and report interrupted saves as an uncertain persisted state.
  • Document SSH enablement for ROM-only cases and link to the Nokia instructions from the Huawei page.
  • Add dependency-free Web Serial transcript tests and run them in the shared build workflow.

The helper leaves the module at U-Boot after completion. It configures UART access; it does not install firmware or change Linux login credentials. The existing Huawei, FS and YMODEM implementation files are unchanged.

Validation

  • npm test: 28 passed, no failed or skipped tests (Node 24.22.1).
  • The same tests under the CI's Node 22 line (22.23.4): 28 passed.
  • npm run build: passed, including VitePress client/server bundles, page rendering and image optimization.
  • git diff --check: passed.
  • No dependency or lockfile changes.

Tests cover bannerless/split prompts, ROM-only and continuous-noise timeouts, nonce verification, confirmation/abort handling, settings changes during confirmation, invalid environment reads, failed readback, failed/interrupted saves, restarts during commands, disconnects, FTDI BREAK recovery and stalled writes.

Draft for review: physical G-010S-A validation is still outstanding. The tests use simulated Web Serial streams; no device was flashed or configured while preparing this change.

Comment thread .vitepress/theme/lib/nokiaSerial.js Resolved
Comment thread ont/ont-huawei-ma5671a-root-web.md Resolved
Comment thread tests/nokiaSerial.test.js Resolved
@shteudguy
shteudguy marked this pull request as ready for review November 7, 2026 17:18
@simonebortolin