Controller for Solar Thermal – Open Source
CoSTOS is an open-source controller for solar thermal systems: the box that decides when the solar pump runs, how fast, and when it has to stop to protect the store and the collector. It runs on a Linux single-board computer (Raspberry Pi 3, 4 or 5), is written in Rust, and is configured completely through a web interface.
Status: early development. Milestone 1 has started: the control core and the safety supervisor exist as tested Rust libraries, nothing talks to hardware yet. Don't use this to control a real system. When it is ready to be tested, this README will say so.
Commercial solar controllers work, but they are closed: you can't see why they decided something, you can't add a function, and getting data out of them needs reverse-engineered protocols. CoSTOS is meant to be a controller you can read, test and extend, with its data available everywhere you need it.
The first goal is to replace a RESOL DeltaSol BX Plus in a real installation, so that's the reference for which functions come first.
- Solar control: ΔT pump control with hysteresis, speed control for high-efficiency pumps (PWM), store maximum, collector emergency shutdown. Later: collector cooling, tube collector function, frost protection, heat quantity metering.
- Sensors: Pt1000 via an LTC2983 (up to 9 sensors on one chip, so the Pt1000s of an existing controller can stay) or a MAX31865 (one sensor, e.g. the collector), and DS18x20 1-Wire sensors (DS1820/DS18S20, DS18B20, DS1822). Mix them freely.
- Web interface for everything: live status, history, manual mode, and all configuration, including a setup wizard that shows live readings so you can identify sensors and test outputs. No config files to edit. Status pages are readable without login, any change needs one.
- Data: every value pushed to VictoriaMetrics once per second, buffered on disk while the database is unreachable and backfilled afterwards. Optional (off by default): MQTT with Home Assistant discovery.
- Safety first: outputs off by default, hardware and software watchdogs, plausibility checks on every sensor, and a safety layer that can only switch things off, never on. See Safety.
- Raspberry Pi 4 or Raspberry Pi 5 with its own USB-C power supply, or a Raspberry Pi 3 B / B+ with its micro-USB supply (should work, untested; details)
- The CoSTOS HAT (1-Wire edition or PT edition; which one?), or for a bench setup: an LTC2983 or MAX31865 for Pt1000 sensors, a 4.7 kΩ pull-up for DS18x20 sensors
- A high-efficiency pump with a PWM input in the solar profile (Wilo PWM2 / iPWM2 such as the Wilo Yonos PARA ST …/iPWM2, Grundfos profile C). This is a safety requirement: the pump stays permanently on 230 V and is started, regulated and stopped over PWM, and with the solar profile a missing signal means stop, so any failure of the Pi or the HAT stops the pump. A feedback output (iPWM) is recommended. Pumps with a heating profile or without PWM need a cut-off relay on the HAT's optional relay output. Details: Pump requirement
- An independent overtemperature cut-out on the store. CoSTOS does not replace that.
Mains wiring belongs in the hands of a qualified electrician.
- Architecture: goals, safety concept, hardware, software structure, web interface, data export, testing and the migration plan.
- Hardware needed: parts lists and build instructions, starting with the PWM pump output.
- HAT: the plug-on board that combines all of it: the
editions compared, and which one to choose.
- 1-Wire edition (1 Pt1000 + two 1-Wire buses): the board as it will be built, wiring, costs.
- PT edition (8 Pt1000 + one 1-Wire bus, for installations that keep their existing sensors).
- HAT development: why the HAT is built this way: decisions D1–D25, the alternatives that were dropped, the simulations, the rev A prototype and its bring-up and tests.
- Reference installation: the system CoSTOS is built to control first.
A Cargo workspace (layout: ARCHITECTURE 6.1). So far:
| Crate | What it does | Status |
|---|---|---|
crates/costos-core |
Control logic, no_std: temperature, time, sensor and duty types (the rules of ARCHITECTURE 6.1); ΔT control with the flow/return switch-off, store maximum, speed control (PI or BX-like steps), start profiles, anti-seize run and full-speed purge, and the control cycle that chains them |
🟢 milestone 1 done |
crates/costos-safety |
Safety supervisor, no_std: sensor unknown → off, collector and store emergency shutdown with hysteresis and latch, minimum off time; can only reduce the request |
🟢 milestone 1 done |
crates/costos-replay |
PC tool: replays recorded BX Plus days (tests/replay) through the control and lists where CoSTOS decides differently |
🟢 |
crates/costos-cycle |
One control second, no_std: sensor offsets, plausible ranges, control chain, inhibit, safety supervisor, plausibility checks, heat counter. The daemon and the simulation both call it |
🟢 |
crates/costos-sim |
Thermal model of the reference solar loop and closed-loop scenario tests of the whole control second (sunny, cloudy, stagnation, sensor faults and offsets, stuck pump, restarts) | 🟢 milestone 2 done |
crates/costos-config |
The settings document (strict JSON, validated by the control crates' own checks), generic and reference defaults (reference.json), revision store with atomic writes, restore and fallback |
🟡 milestone 4 started |
crates/costosd |
The daemon: settings and counters from the state directory, the control loop against a backend (for now the simulator, real time or accelerated), status lines, logged interventions and alarms | 🟡 skeleton, simulator only |
tools/sim |
ngspice circuit simulations of the HAT, and the Python yield simulation (ARCHITECTURE 8.2) | 🟢 |
cargo test --workspace # unit, property, replay and simulation tests
cargo clippy --workspace --all-targets -- -D warnings # lints as in CI
cargo run --release -p costosd -- --state-dir /tmp/costos --days 3 --status-every 3600
# three simulated days through the daemonCI also builds costos-core, costos-safety and costos-cycle for a
bare-metal RISC-V target, so they stay free of std.
Please read CONTRIBUTING.md first, whether you are a
person or an AI assistant: the rules for the control and safety code
(no_std, no panics, the supervisor only reduces), comments, tests,
commits and docs.
- vbus2influx: reads a RESOL
controller over VBus and pushes the data to InfluxDB/VictoriaMetrics.
CoSTOS uses the same metric names (with the prefix
costos), so dashboards carry over.