Original file line number Diff line number Diff line change
Expand Up @@ -18,6 +18,8 @@ def setup_algorithm(self) -> None:
""" bereitet die Daten für den Algorithmus vor und startet diesen.
"""
try:
# vor PV, greift auf IO-Aktion stepwise_control zu
data.data.io_actions.setup()
data.data.pv_all_data.calc_power_for_all_components()
data.data.bat_all_data.calc_power_for_all_components()
for cp in data.data.cp_data.values():
Expand All @@ -34,7 +36,6 @@ def setup_algorithm(self) -> None:
data.data.cp_all_data.get_cp_sum()
data.data.cp_all_data.no_charge()
data.data.counter_all_data.set_home_consumption()
data.data.io_actions.setup()
except Exception:
log.exception("Fehler im Prepare-Modul")
data.data.print_all()
8 changes: 5 additions & 3 deletions packages/control/process.py
Original file line number Diff line number Diff line change
Expand Up @@ -16,6 +16,7 @@
from modules.common.fault_state_level import FaultStateLevel
from modules.io_actions.controllable_consumers.dimming.api_io import DimmingIo
from modules.io_actions.controllable_consumers.dimming_direct_control.api import DimmingDirectControl
from modules.io_actions.generator_systems.stepwise_control.api_eebus import StepwiseControlEebus
from modules.io_actions.generator_systems.stepwise_control.api_io import StepwiseControlIo

log = logging.getLogger(__name__)
Expand Down Expand Up @@ -83,16 +84,17 @@ def process_algorithm_results(self) -> None:
data.data.io_states[f"io_states{d['id']}"].data.set.digital_output[d["digital_output"]] = (
not action.dimming_active() # active output (True) if no dimming
)
if isinstance(action, StepwiseControlIo):
if isinstance(action, (StepwiseControlEebus, StepwiseControlIo)):
# check if passthrough is enabled
if action.config.configuration.passthrough_enabled:
if (action.config.configuration.passthrough_enabled and
action.config.configuration.io_output_device is not None):
# find output pattern by value
for pattern in action.config.configuration.output_pattern:
if pattern["value"] == action.control_stepwise()[0]:
# set digital outputs according to matching output_pattern
for output in pattern["matrix"].keys():
data.data.io_states[
f"io_states{action.config.configuration.io_device}"
f"io_states{action.config.configuration.io_output_device}"
].data.set.digital_output[output] = pattern["matrix"][output]
for io in data.data.system_data.values():
if isinstance(io, AbstractIoDevice):
Expand Down
16 changes: 15 additions & 1 deletion packages/helpermodules/update_config.py
Original file line number Diff line number Diff line change
Expand Up @@ -58,7 +58,7 @@

class UpdateConfig:

DATASTORE_VERSION = 133
DATASTORE_VERSION = 134

valid_topic = [
"^openWB/bat/config/bat_control_activated$",
Expand Down Expand Up @@ -3421,3 +3421,17 @@ def upgrade(topic: str, payload) -> None:
return {topic: provider}
self._loop_all_received_topics(upgrade)
self._append_datastore_version(133)

def upgrade_datastore_134(self) -> None:
def upgrade(topic: str, payload) -> Optional[dict]:
if re.search("openWB/io/action/[0-9]+/config", topic) is not None:
config = decode_payload(payload)
if config.get("type") == "stepwise_control":
if config["configuration"]["passthrough_enabled"] is True:
if config["configuration"].get("io_output_device") is None:
config["configuration"]["io_output_device"] = config["configuration"].get("io_device")
else:
config["configuration"]["io_output_device"] = None
return {topic: config}
self._loop_all_received_topics(upgrade)
self._append_datastore_version(134)
Original file line number Diff line number Diff line change
Expand Up @@ -42,6 +42,34 @@ def __init__(self, config: StepwiseControlSetup):
)
super().__init__()

def get_step(self) -> float:
step: float = 0
try:
max_output_inverter: float = 0
for inverter in self.config.configuration.devices:
if data.data.pv_data[f"pv{inverter['id']}"].data.config.max_ac_out == 0:
msg = "Maximale Ausgangsleistung des Wechselrichters muss im Lastmanagement konfiguriert werden."
control_command_log.error(msg)
raise ValueError(msg)
max_output_inverter += data.data.pv_data[f"pv{inverter['id']}"].data.config.max_ac_out
percentage = self.lpp_value / max_output_inverter
except ZeroDivisionError:
msg = ("Bitte unter Konfiguration -> Lastmanagement die maximale Ausgangsleistung"
" des Wechselrichters angeben.")
log.exception(msg)
control_command_log.info(msg)
percentage = 0
except ValueError:
percentage = 0
except Exception:
log.exception("Fehler beim Berechnen des Steuerungsschritts.")
percentage = 0
for s in [0, 0.3, 0.6, 1.0]:
if percentage <= s:
step = s
break
return step

def setup(self) -> None:
with ModifyLoglevelContext(control_command_log, logging.DEBUG):
if check_fault_state_io_device(self.config.configuration.io_device):
Expand All @@ -57,34 +85,20 @@ def setup(self) -> None:
].data.get.digital_input_prev[DigitalInputMapping.LPP_ACTIVE.name]
changed = True if self.lpp_value != lpp_value_prev or self.lpp_active != lpp_active_prev else False

max_output_inverter = 0
for inverter in self.config.configuration.devices:
max_output_inverter += data.data.pv_data[f"pv{inverter['id']}"].data.config.max_ac_out

if self.lpp_active:
try:
self.step = self.lpp_value / max_output_inverter
except ZeroDivisionError:
msg = ("Bitte unter Konfiguration -> Lastmanagement die maximale Ausgangsleistung"
" des Wechselrichters angeben.")
log.exception(msg)
control_command_log.info(msg)
self.step = 0
for s in [0, 0.25, 0.5, 0.75, 1.0]:
if self.step <= s:
self.step = s
break
self.step = self.get_step()
if changed:
Pub().pub(f"openWB/set/io/action/{self.config.id}/timestamp", create_timestamp())
control_command_log.info(f"EEBus-Steuerung: LPP-Wert {self.lpp_value} / "
f"max. PV-Leistung {max_output_inverter} = {self.step}")
control_command_log.info(f"EZA-Begrenzung mit Wert {self.step*100}% aktiviert.")
control_command_log.info(
f"EEBus-Steuerung: EZA-Begrenzung mit LPP-Wert {self.lpp_value}W aktiviert.")
for device in self.config.configuration.devices:
control_command_log.info(
f"Erzeugungsanlage {get_component_name_by_id(device['id'])} "
f"auf {self.step*100}% begrenzt."
f"auf {self.lpp_value}W begrenzt. Gestufte Ansteuerung: "
f"{self.step*100:.0f}% der maximalen Ausgangsleistung."
Comment on lines 94 to +98
)
else:
self.step = 1
if changed:
Pub().pub(f"openWB/set/io/action/{self.config.id}/timestamp", None)
control_command_log.info("EZA-Begrenzung aufgehoben.")
Expand All @@ -95,28 +109,17 @@ def control_stepwise(self) -> Tuple[Optional[float], LoadmanagementLimit]:
LimitingValue.CONTROLLABLE_CONSUMERS_ERROR.value.format(get_io_name_by_id(
self.config.configuration.io_device)),
LimitingValue.CONTROLLABLE_CONSUMERS_ERROR))
for pattern in self.config.configuration.input_pattern:
for digital_input, value in pattern["matrix"].items():
if data.data.io_states[f"io_states{self.config.configuration.io_device}"
].data.get.digital_input[digital_input] != value:
break

if self.lpp_active:
if self.step != 1:
limit = LoadmanagementLimit(
LimitingValue.CONTROL_STEPWISE.value.format(self.step*100),
LimitingValue.CONTROL_STEPWISE)
else:
if pattern["value"] is None:
return 0, LoadmanagementLimit(LimitingValue.MISSING_CONFIGURATION.value,
LimitingValue.MISSING_CONFIGURATION)
# Alle digitalen Eingänge entsprechen dem Pattern
elif pattern["value"] != 1:
limit = LoadmanagementLimit(
LimitingValue.CONTROL_STEPWISE.value.format(pattern["value"]*100),
LimitingValue.CONTROL_STEPWISE)
else:
limit = LoadmanagementLimit("Keine Leistungsbegrenzung aktiv.", None)
return pattern["value"], limit
limit = LoadmanagementLimit("Keine Leistungsbegrenzung aktiv.", None)
else:
# Zustand entspricht keinem Pattern
return 0, LoadmanagementLimit(
LimitingValue.CONTROL_STEPWISE.value.format(0),
LimitingValue.CONTROL_STEPWISE)
limit = LoadmanagementLimit("Keine Leistungsbegrenzung aktiv.", None)
return self.step, limit


def create_action(config: StepwiseControlSetup, parent_device_type: str):
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,46 @@
from unittest.mock import Mock

import pytest

from control import data
from modules.io_actions.generator_systems.stepwise_control.api_eebus import StepwiseControlEebus
from modules.io_actions.generator_systems.stepwise_control.config import StepwiseControlConfig, StepwiseControlSetup


@pytest.fixture()
def mock_data() -> None:
data.data_init(Mock())


def _build_action(lpp_value: float, max_ac_out: float) -> StepwiseControlEebus:
config = StepwiseControlSetup(configuration=StepwiseControlConfig(
io_device=0,
devices=[{"type": "inverter", "id": 1}],
))
action = StepwiseControlEebus(config)
action.lpp_value = lpp_value
data.data.pv_data["pv1"] = Mock(data=Mock(config=Mock(max_ac_out=max_ac_out)))
return action


@pytest.mark.parametrize(
"lpp_value,max_ac_out,expected",
[
pytest.param(0, 10000, 0, id="0W -> 0%"),
pytest.param(1000, 10000, 0.3, id="10% -> 30%"),
pytest.param(3000, 10000, 0.3, id="30% -> 30%"),
pytest.param(4500, 10000, 0.6, id="45% -> 60%"),
pytest.param(6000, 10000, 0.6, id="60% -> 60%"),
pytest.param(9000, 10000, 1.0, id="90% -> 100%"),
],
)
def test_get_step(mock_data, lpp_value, max_ac_out, expected):
action = _build_action(lpp_value=lpp_value, max_ac_out=max_ac_out)

assert action.get_step() == expected


def test_get_step_handles_zero_division(mock_data):
action = _build_action(lpp_value=5000, max_ac_out=0)

assert action.get_step() == 0
Original file line number Diff line number Diff line change
Expand Up @@ -11,6 +11,7 @@ class StepwiseControlConfig:
devices: List[Dict] = field(default_factory=empty_list_factory)
# [{"type": "inverter", "id": 1},...]
passthrough_enabled: bool = False
io_output_device: Optional[int] = None
output_pattern: List[Dict] = field(default_factory=empty_io_pattern_stepwise_factory)


Expand Down