Diff view
96 changes: 94 additions & 2 deletions packages/modules/devices/solax/solax/bat.py
Original file line number Diff line number Diff line change
@@ -1,5 +1,9 @@
#!/usr/bin/env python3
from typing import Any, TypedDict
import logging
from typing import Any, Optional, TypedDict

from pymodbus.constants import Endian
from pymodbus.payload import BinaryPayloadBuilder

from modules.common import modbus
from modules.common.abstract_device import AbstractBat
Expand All @@ -10,9 +14,20 @@
from modules.common.simcount import SimCounter
from modules.common.store import get_bat_value_store
from modules.devices.solax.solax.config import SolaxBatSetup, Solax
from modules.devices.solax.solax.version import SolaxVersion
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType

log = logging.getLogger(__name__)

# Solax Remote Control Registers (Holding Registers)
REMOTE_CONTROL_MODE_REG = 0x7C
MODE_DISABLED = 0
MODE_4_PUSH_POWER = 4
SET_TYPE_SET = 1
MODE_4_TIMEOUT_DISABLED = 0
MODE4_BLOCK_REG_COUNT = 15


class KwargsDict(TypedDict):
client: modbus.ModbusTcpClient_
Expand All @@ -31,11 +46,12 @@ def initialize(self) -> None:
self.store = get_bat_value_store(self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))
self.peak_filter = PeakFilter(ComponentType.BAT, self.component_config.id, self.fault_state)
self.last_mode: Optional[str] = 'Undefined'

def update(self) -> None:
unit = self.device_config.configuration.modbus_id

# kein Speicher für Versionen G2 und G4
# Basiswerte aus dem Batterie-Registersatz lesen
power = self.__tcp_client.read_input_registers(0x0016, ModbusDataType.INT_16, unit=unit)
soc = self.__tcp_client.read_input_registers(0x001C, ModbusDataType.UINT_16, unit=unit)
self.peak_filter.check_values(power)
Expand All @@ -48,5 +64,81 @@ def update(self) -> None:
)
self.store.set(bat_state)

def set_power_limit(self, power_limit: Optional[int]) -> None:
if self.power_limit_controllable() is False:
log.debug("SolaX set_power_limit: aktive Speichersteuerung für diese Version nicht unterstützt")
return

unit = self.device_config.configuration.modbus_id
log.debug(f"SolaX set_power_limit: power_limit={power_limit}, last_mode={self.last_mode}")

if power_limit is None:
log.debug("Keine Batteriesteuerung, Selbstregelung durch Wechselrichter")
if self.last_mode is not None:
with self.__tcp_client:
self.__tcp_client.write_register(
REMOTE_CONTROL_MODE_REG,
MODE_DISABLED,
data_type=ModbusDataType.UINT_16,
unit=unit,
)
self.last_mode = None
return

if power_limit < 0:
self.last_mode = 'discharge'
elif power_limit > 0:
self.last_mode = 'charge'
else:
self.last_mode = 'stop'

push_power = self._get_mode4_push_power(int(power_limit))
self._write_mode4(push_power, unit)

def _get_mode4_push_power(self, power_limit: int) -> int:
# openWB power_limit semantics:
# <0 discharge, 0 stop, >0 charge
# Mode 4 push_power semantics:
# >0 discharge, 0 stop, <0 charge
push_power = int(power_limit * -1)
log.debug(f"SolaX Mode4 target: power_limit={power_limit}W -> push_power={push_power}W")
return push_power

def _write_mode4(self, push_power: int, unit: int) -> None:
log.debug(
(
f"SolaX Mode4 write: mode={MODE_4_PUSH_POWER}, set_type={SET_TYPE_SET}, "
f"timeout={MODE_4_TIMEOUT_DISABLED}s, push_power={push_power}W"
)
)
builder = BinaryPayloadBuilder(byteorder=Endian.Big, wordorder=Endian.Little)
builder.add_16bit_uint(MODE_4_PUSH_POWER)
builder.add_16bit_uint(SET_TYPE_SET)
builder.add_32bit_int(0)
builder.add_32bit_int(0)
builder.add_16bit_uint(0)
builder.add_16bit_uint(0)
builder.add_32bit_uint(0)
builder.add_32bit_int(0)
builder.add_16bit_uint(MODE_4_TIMEOUT_DISABLED)
builder.add_32bit_int(push_power)
payload = builder.to_registers()
if len(payload) != MODE4_BLOCK_REG_COUNT:
raise RuntimeError(
f"Unexpected mode4 payload size {len(payload)}, expected {MODE4_BLOCK_REG_COUNT}"
)

with self.__tcp_client:
self.__tcp_client.write_register(REMOTE_CONTROL_MODE_REG, payload, unit=unit)

def power_limit_controllable(self) -> bool:
device_config = getattr(self, 'device_config', self.kwargs.get('device_config'))
if device_config is None:
return False
try:
return SolaxVersion(device_config.configuration.version) == SolaxVersion.G3
except ValueError:
return False


component_descriptor = ComponentDescriptor(configuration_factory=SolaxBatSetup)
41 changes: 41 additions & 0 deletions packages/modules/devices/solax/solax/bat_test.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,41 @@
from types import SimpleNamespace

from modules.devices.solax.solax import bat
from modules.devices.solax.solax.config import Solax, SolaxBatSetup, SolaxConfiguration
from modules.devices.solax.solax.version import SolaxVersion


def _create_solax_bat(version: SolaxVersion) -> bat.SolaxBat:
config = SolaxConfiguration(version=version)
device_config = Solax(configuration=config)
return bat.SolaxBat(SolaxBatSetup(), device_config=device_config, client=SimpleNamespace())


def test_get_mode4_push_power_stop_is_zero() -> None:
solax_bat = _create_solax_bat(SolaxVersion.G3)
assert solax_bat._get_mode4_push_power(0) == 0


def test_get_mode4_push_power_discharge_is_positive() -> None:
solax_bat = _create_solax_bat(SolaxVersion.G3)
assert solax_bat._get_mode4_push_power(-700) == 700


def test_get_mode4_push_power_charge_is_negative() -> None:
solax_bat = _create_solax_bat(SolaxVersion.G3)
assert solax_bat._get_mode4_push_power(1000) == -1000


def test_power_limit_controllable_true_for_g3() -> None:
solax_bat = _create_solax_bat(SolaxVersion.G3)
assert solax_bat.power_limit_controllable() is True


def test_power_limit_controllable_false_for_g2() -> None:
solax_bat = _create_solax_bat(SolaxVersion.G2)
assert solax_bat.power_limit_controllable() is False


def test_power_limit_controllable_false_for_g4() -> None:
solax_bat = _create_solax_bat(SolaxVersion.G4)
assert solax_bat.power_limit_controllable() is False
Loading