1 change: 1 addition & 0 deletions packages/control/algorithm/integration_test/conftest.py
Original file line number Diff line number Diff line change
Expand Up @@ -52,6 +52,7 @@ def data_() -> None:
data.data.counter_all_data.data.get.hierarchy = NESTED_HIERARCHY
data.data.counter_all_data.data.config.consider_less_charging = True
data.data.io_actions = IoActions()
data.data.general_data.data.chargemode_config.pv_charging.retry_failed_phase_switches = True


@dataclass
Expand Down
64 changes: 24 additions & 40 deletions packages/control/chargepoint/chargepoint.py
Original file line number Diff line number Diff line change
Expand Up @@ -302,18 +302,18 @@ def check_deviating_contactor_states(self, phase_a: int, phase_b: int) -> bool:
return (phase_a == 1 and phase_b in [2, 3]) or (phase_b == 1 and phase_a in [2, 3])

def _is_phase_switch_required(self) -> bool:
phase_switch_required = False
if self.data.get.evse_signaling == EvseSignaling.HLC:
return False
if (self.data.control_parameter.state == ChargepointState.WAIT_FOR_USING_PHASES and
elif (self.data.control_parameter.state == ChargepointState.WAIT_FOR_USING_PHASES and
(self.data.set.current != 0 and self.data.set.current_prev != 0)):
phase_switch_required = False
return False
# Manche EVs brauchen nach der Umschaltung mehrere Zyklen, bis sie mit den drei Phasen laden. Dann darf
# nicht zwischendurch eine neue Umschaltung getriggert werden.
elif ((((self.data.control_parameter.state == ChargepointState.PHASE_SWITCH_AWAITED or
self.data.control_parameter.state == ChargepointState.SWITCH_OFF_DELAY) and
# Nach Ablauf der Laden aktiv halten Zeit, sollte mit der vorgegebenen Phasenzahl geladen werden.
self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use)) or
self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use) and
self.failed_phase_switches_reached() is False) or
# Vorgegebene Phasenzahl hat sich geändert und es wird geladen
(self.check_deviating_contactor_states(self.data.set.phases_to_use,
self.data.control_parameter.phases) and
Expand All @@ -324,33 +324,18 @@ def _is_phase_switch_required(self) -> bool:
((self.data.set.current != 0 and self.data.get.charge_state) or
(self.data.set.current != 0 and self.data.set.current_prev == 0) or
self.data.set.current == 0)):
phase_switch_required = True
return True
elif (self.data.control_parameter.state == ChargepointState.NO_CHARGING_ALLOWED and
(self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use) or
((self.check_deviating_contactor_states(self.data.set.phases_to_use, self.data.get.phases_in_use) and
self.failed_phase_switches_reached() is False) or
# Vorgegebene Phasenzahl hat sich geändert
self.check_deviating_contactor_states(self.data.set.phases_to_use,
self.data.control_parameter.phases)) and
# Wenn der Ladevorgang gestartet wird, muss vor dem ersten Laden umgeschaltet werden.
self.data.set.current != 0 and self.data.get.charge_state is False):
phase_switch_required = True
if phase_switch_required:
# Umschaltung fehlgeschlagen
if self.data.set.phases_to_use != self.data.get.phases_in_use:
if data.data.general_data.data.chargemode_config.pv_charging.retry_failed_phase_switches:
if self.data.control_parameter.failed_phase_switches > self.MAX_FAILED_PHASE_SWITCHES:
phase_switch_required = False
self.set_state_and_log(
"Keine Phasenumschaltung, da die maximale Anzahl an Fehlversuchen erreicht wurde.")
else:
# Umschaltung vor Ladestart zulassen
if (self.data.set.log.imported_since_plugged != 0 and
self.data.control_parameter.failed_phase_switches > 0):
phase_switch_required = False
self.set_state_and_log(
"Keine Phasenumschaltung, da wiederholtes Anstoßen der Umschaltung in den übergreifenden "
"Ladeeinstellungen deaktiviert wurde. Die aktuelle "
"Phasenzahl wird bis zum nächsten Lademoduswechsel beibehalten.")
return phase_switch_required
return True
else:
return False

STOP_CHARGING = ", dafür wird die Ladung unterbrochen."

Expand Down Expand Up @@ -384,11 +369,11 @@ def _set_failed_phase_switches() -> None:
if self.data.control_parameter.state == ChargepointState.WAIT_FOR_USING_PHASES:
if check_timestamp(self.data.control_parameter.timestamp_charge_start,
charging_ev.ev_template.data.keep_charge_active_duration) is False:
if self.hw_supports_phase_switch() and self.failed_phase_switches_reached():
if self.hw_supports_phase_switch():
if phase_switch.phase_switch_thread_alive(self.num) is False:
self.data.control_parameter.state = ChargepointState.PHASE_SWITCH_AWAITED
_set_failed_phase_switches()
if self._is_phase_switch_required() is False:
_set_failed_phase_switches()
self.data.control_parameter.state = ChargepointState.CHARGING_ALLOWED
else:
_set_failed_phase_switches()
Expand All @@ -399,10 +384,6 @@ def _set_failed_phase_switches() -> None:
def initiate_phase_switch(self):
"""prüft, ob eine Phasenumschaltung erforderlich ist und führt diese durch.
"""
def _set_failed_phase_switches() -> None:
# Umschaltung fehlgeschlagen
if self.data.set.phases_to_use != self.data.get.phases_in_use:
self.data.control_parameter.failed_phase_switches += 1
try:
if self.data.get.evse_signaling == EvseSignaling.HLC:
return
Expand Down Expand Up @@ -462,8 +443,7 @@ def get_phases_by_selected_chargemode(self, phases_chargemode: int) -> int:
charging_ev = self.data.set.charging_ev_data
if self.data.get.evse_signaling == EvseSignaling.HLC:
phases = self.data.get.phases_in_use
elif ((self.data.config.auto_phase_switch_hw is False and self.data.get.charge_state) or
self.data.control_parameter.failed_phase_switches > self.MAX_FAILED_PHASE_SWITCHES):
elif self.data.config.auto_phase_switch_hw is False and self.data.get.charge_state:
# Wenn keine Umschaltung verbaut ist, die Phasenzahl nehmen, mit der geladen wird. Damit werden zB auch
# einphasige EV an dreiphasigen openWBs korrekt berücksichtigt.
phases = self.data.get.phases_in_use or self.data.set.phases_to_use
Expand Down Expand Up @@ -829,7 +809,7 @@ def cp_state_hw_support_phase_switch(self) -> bool:
self.data.get.charge_state and
(self.data.control_parameter.state == ChargepointState.CHARGING_ALLOWED or
self.data.control_parameter.state == ChargepointState.PHASE_SWITCH_DELAY)):
return self.failed_phase_switches_reached()
return self.failed_phase_switches_reached() is False
else:
return False

Expand All @@ -840,12 +820,16 @@ def hw_supports_phase_switch(self) -> bool:
self.data.set.log.imported_since_plugged == 0))

def failed_phase_switches_reached(self) -> bool:
if ((data.data.general_data.data.chargemode_config.pv_charging.retry_failed_phase_switches and
self.data.control_parameter.failed_phase_switches > self.MAX_FAILED_PHASE_SWITCHES) or
(data.data.general_data.data.chargemode_config.pv_charging.retry_failed_phase_switches is False and
self.data.control_parameter.failed_phase_switches == 1)):
if (data.data.general_data.data.chargemode_config.pv_charging.retry_failed_phase_switches and
self.data.control_parameter.failed_phase_switches > self.MAX_FAILED_PHASE_SWITCHES):
Comment on lines +823 to +824
# bei deaktiverter Wiederholung der Umschaltung nur den gewünschten Umschaltvorgang durchführen,
# keinen Korrekturversuch
self.set_state_and_log(
Comment on lines +823 to 827
"Keine Phasenumschaltung, da die maximale Anzahl an Fehlversuchen erreicht wurde. ")
return False
else:
return True
elif (data.data.general_data.data.chargemode_config.pv_charging.retry_failed_phase_switches is False and
self.data.set.log.imported_since_plugged != 0):
# vor Ladestart trotzdem umschalten
return True
else:
return False