28 changes: 28 additions & 0 deletions simpleAPI/simpleAPI_mqtt.py
Original file line number Diff line number Diff line change
Expand Up @@ -567,6 +567,10 @@ def _handle_write_operation(self, topic: str, payload: str):
success = self._handle_bat_mode_operation(payload)
if success:
self._clear_set_topic(topic)
elif operation == 'bat_power_reserve':
success = self._handle_bat_power_reserve_operation(payload)
if success:
self._clear_set_topic(topic)
else:
log.error(f"Unknown operation: {operation}")

Expand Down Expand Up @@ -760,6 +764,30 @@ def _handle_bat_mode_operation(self, payload: str) -> bool:
log.info(f"Set bat_mode to {payload}")
return True

def _handle_bat_power_reserve_operation(self, payload: str) -> bool:
"""Handle battery power reserve operation.

Sets the power (in Watts) that openWB reserves for the battery
during PV surplus charging, before releasing surplus to EV charging.
Value 0 = no reservation (equivalent to ev_mode behaviour).
Allows external energy managers to do proportional battery/EV sharing
without switching bat_mode.
"""
try:
watts = int(payload)
except ValueError:
log.error(f"Invalid bat_power_reserve value: {payload!r}. Must be an integer (Watts).")
return False

if watts < 0:
log.error(f"Invalid bat_power_reserve value: {watts}. Must be >= 0.")
return False

target_topic = "openWB/set/general/chargemode_config/pv_charging/bat_power_reserve"
self.client.publish(target_topic, watts, qos=0, retain=True)
log.info(f"Set bat_power_reserve to {watts}W")
return True

def _handle_instant_charging_limit_operation(self, payload: str) -> bool:
"""Handle instant charging limit type operation."""
valid_limits = ['none', 'soc', 'amount']
Expand Down
32 changes: 32 additions & 0 deletions simpleAPI/src/ParameterHandler.php
Original file line number Diff line number Diff line change
Expand Up @@ -229,6 +229,8 @@ public function writeParameter($param, $value, $chargepointId = null)
return $this->setChargepointLock($chargepointId, $value);
case 'bat_mode':
return $this->setBatMode($value);
case 'bat_power_reserve':
return $this->setBatPowerReserve($value);
case 'instant_charging_limit':
return $this->setInstantChargingLimit($chargepointId, $value);
case 'instant_charging_amount':
Expand Down Expand Up @@ -1534,6 +1536,36 @@ private function setBatMode($value)
}
}

/**
* Reservierte Batterie-Ladeleistung setzen (W)
* Setzt openWB/set/general/chargemode_config/pv_charging/bat_power_reserve
* Ermöglicht externes Energiemanagement der Speicherreservierung ohne UI-Eingriff.
*/
private function setBatPowerReserve($value)
{
$watts = intval($value);

if ($watts < 0) {
return ['success' => false, 'message' => 'bat_power_reserve must be >= 0'];
}

try {
$topic = "openWB/set/general/chargemode_config/pv_charging/bat_power_reserve";

if ($this->mqttClient->setValue($topic, $watts)) {
return [
'success' => true,
'message' => "bat_power_reserve set to {$watts}W",
'data' => ['bat_power_reserve' => $watts]
];
}

return ['success' => false, 'message' => 'Failed to set bat_power_reserve'];
} catch (Exception $e) {
return ['success' => false, 'message' => 'Error setting bat_power_reserve: ' . $e->getMessage()];
}
}

/**
* Lese openWB/system/lastlivevaluesJson Topic 1:1 aus
*/
Expand Down