3 changes: 2 additions & 1 deletion packages/control/algorithm/additional_current.py
Original file line number Diff line number Diff line change
Expand Up @@ -24,7 +24,8 @@ def set_additional_current(self) -> None:
f"counter{counter.num}"))
for preferenced_loads in preferenced_loads_groups:
common.update_raw_data(preferenced_loads)
log.info(f"Zähler {counter.num}, Verbraucher {filtered_loads_to_str(preferenced_loads)}")
if len(preferenced_loads) > 0:
log.info(f"Zähler {counter.num}, Verbraucher {filtered_loads_to_str(preferenced_loads)}")
while len(preferenced_loads):
load = preferenced_loads[0]
missing_currents, counts = common.get_missing_currents_left(preferenced_loads)
Expand Down
2 changes: 2 additions & 0 deletions packages/control/algorithm/integration_test/conftest.py
Original file line number Diff line number Diff line change
Expand Up @@ -80,11 +80,13 @@ class ParamsExpectedSetCurrent:
expected_current_cp3: float = 0
expected_current_cp4: float = 0
expected_current_cp5: float = 0
expected_current_consumer7: float = 0


def assert_expected_current(params: ParamsExpectedSetCurrent):
for i in range(3, 6):
assert data.data.cp_data[f"cp{i}"].data.set.current == getattr(params, f"expected_current_cp{i}")
assert data.data.consumer_data["consumer7"].data.set.current == params.expected_current_consumer7


@pytest.fixture()
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -108,9 +108,10 @@ class ParamsLimit(ParamsExpectedSetCurrent, ParamsExpectedCounterSet):
raw_currents_left_counter6=[16, 12, 14],
expected_state_str=(f"Es kann nicht mit der vorgegebenen Stromstärke geladen werden"
f"{LimitingValue.CURRENT.value.format('Garage')}"),
expected_current_cp3=14,
expected_current_cp3=13.5,
expected_current_cp4=12,
expected_current_cp5=14,
expected_current_consumer7=0.5,
expected_raw_power_left=12110,
expected_raw_currents_left_counter0=[0, 18, 17],
expected_raw_currents_left_counter6=[16, 0, 0]),
Expand All @@ -120,12 +121,13 @@ class ParamsLimit(ParamsExpectedSetCurrent, ParamsExpectedCounterSet):
raw_currents_left_counter6=[16]*3,
expected_state_str=(f"Es kann nicht mit der vorgegebenen Stromstärke geladen werden"
f"{LimitingValue.POWER.value.format('Garage')}"),
expected_current_cp3=10.461538461538462,
expected_current_cp4=6.769230769230769,
expected_current_cp5=6.769230769230769,
expected_current_cp3=10.346153846153847,
expected_current_cp4=6.576923076923077,
expected_current_cp5=6.576923076923077,
expected_current_consumer7=0.5,
expected_raw_power_left=0,
expected_raw_currents_left_counter0=[21.53846153846154, 25.23076923076923, 25.23076923076923],
expected_raw_currents_left_counter6=[16, 9.23076923076923, 9.23076923076923]),
expected_raw_currents_left_counter0=[21.153846153846153, 25.423076923076923, 25.423076923076923],
expected_raw_currents_left_counter6=[16, 9.423076923076923, 9.423076923076923]),

# limit by unbalanced load
]
Expand All @@ -144,6 +146,7 @@ def test_instant_charging_limit(params: ParamsLimit, all_cp_instant_charging_1p,

# evaluation
assert_expected_current(params)
assert data.data.consumer_data["consumer7"].data.set.current == 0.5
for i in range(3, 6):
assert data.data.cp_data[
f"cp{i}"].data.get.state_str.replace("\n", "") == params.expected_state_str.replace("\n", "")
Expand Down
34 changes: 24 additions & 10 deletions packages/control/algorithm/integration_test/pv_charging_test.py
Original file line number Diff line number Diff line change
Expand Up @@ -32,6 +32,7 @@ def all_cp_pv_charging_3p():
control_parameter.phases = 1
control_parameter.chargemode = Chargemode.PV_CHARGING
control_parameter.submode = Chargemode.PV_CHARGING
control_parameter.state = ChargepointState.CHARGING_ALLOWED


@pytest.fixture()
Expand All @@ -42,6 +43,10 @@ def all_cp_charging_3p():
data.data.cp_data["cp3"].data.get.power = 6900
data.data.cp_data["cp4"].data.get.power = 5520
data.data.cp_data["cp5"].data.get.power = 5520
data.data.consumer_data["consumer7"].data.get.charge_state = True
data.data.consumer_data["consumer7"].data.get.currents = [0.5, 0, 0]
data.data.consumer_data["consumer7"].data.get.power = 115
data.data.consumer_data["consumer7"].data.set.current = 0.5

for i in range(3, 6):
charging_ev_data = data.data.cp_data[f"cp{i}"].data.set.charging_ev_data
Expand Down Expand Up @@ -153,7 +158,7 @@ def test_pv_delay_expired(all_cp_pv_charging_3p, all_cp_not_charging, monkeypatc
data.data.counter_data["counter0"].data.set.raw_power_left = 31200
data.data.counter_data["counter0"].data.set.raw_currents_left = [32, 30, 31]
data.data.counter_data["counter6"].data.set.raw_currents_left = [16, 12, 14]
data.data.counter_data["counter0"].data.set.reserved_surplus = 9000
data.data.counter_data["counter0"].data.set.reserved_surplus = 9115
data.data.cp_data[
"cp3"].data.control_parameter.timestamp_switch_on_off = 1652683185.0
data.data.cp_data[
Expand All @@ -165,6 +170,10 @@ def test_pv_delay_expired(all_cp_pv_charging_3p, all_cp_not_charging, monkeypatc
"cp4"].data.control_parameter.state = ChargepointState.SWITCH_ON_DELAY
data.data.cp_data[
"cp5"].data.control_parameter.timestamp_switch_on_off = None
data.data.consumer_data[
"consumer7"].data.control_parameter.timestamp_switch_on_off = 1652683185.0
data.data.consumer_data[
"consumer7"].data.control_parameter.state = ChargepointState.SWITCH_ON_DELAY

# execution
Algorithm().calc_current()
Expand All @@ -179,7 +188,7 @@ def test_pv_delay_expired(all_cp_pv_charging_3p, all_cp_not_charging, monkeypatc
"cp4"].data.control_parameter.timestamp_switch_on_off is None
assert data.data.cp_data[
"cp5"].data.control_parameter.timestamp_switch_on_off is None
assert data.data.counter_data["counter0"].data.set.raw_power_left == 24300
assert data.data.counter_data["counter0"].data.set.raw_power_left == 24185
assert data.data.counter_data["counter0"].data.set.surplus_power_left == -690
assert data.data.counter_data["counter0"].data.set.reserved_surplus == 0

Expand All @@ -190,10 +199,11 @@ def test_pv_delay_expired(all_cp_pv_charging_3p, all_cp_not_charging, monkeypatc
raw_power_left=50000,
raw_currents_left_counter0=[40]*3,
raw_currents_left_counter6=[16]*3,
expected_current_cp3=16,
expected_current_cp3=14.375,
expected_current_cp4=8,
expected_current_cp5=8,
expected_raw_power_left=34820,
expected_current_consumer7=5.5,
expected_raw_power_left=34705,
expected_surplus_power_left=1090,
expected_reserved_surplus=0,
expected_released_surplus=0),
Expand All @@ -202,10 +212,11 @@ def test_pv_delay_expired(all_cp_pv_charging_3p, all_cp_not_charging, monkeypatc
raw_power_left=39650,
raw_currents_left_counter0=[40]*3,
raw_currents_left_counter6=[16]*3,
expected_current_cp3=11.248792270531402,
expected_current_cp4=7.248792270531401,
expected_current_cp5=7.2487922705314,
expected_raw_power_left=24470,
expected_current_cp3=10.878199918732223,
expected_current_cp4=6.8827997554740445,
expected_current_cp5=7.201405373552686,
expected_current_consumer7=2.3519152915057484,
expected_raw_power_left=24355,
expected_surplus_power_left=1090,
expected_reserved_surplus=0,
expected_released_surplus=0),
Expand All @@ -217,7 +228,8 @@ def test_pv_delay_expired(all_cp_pv_charging_3p, all_cp_not_charging, monkeypatc
expected_current_cp3=10,
expected_current_cp4=6,
expected_current_cp5=6,
expected_raw_power_left=5635,
expected_current_consumer7=0.5,
expected_raw_power_left=5520.0,
expected_surplus_power_left=-8200,
expected_reserved_surplus=0,
expected_released_surplus=11040),
Expand Down Expand Up @@ -256,7 +268,8 @@ def test_surplus(params: ParamsSurplus, all_cp_pv_charging_3p, all_cp_charging_3
expected_current_cp3=10,
expected_current_cp4=6,
expected_current_cp5=6,
expected_raw_power_left=17400,
expected_current_consumer7=0.5,
expected_raw_power_left=17285,
expected_surplus_power_left=-690,
expected_reserved_surplus=0,
expected_released_surplus=0),
Expand All @@ -270,6 +283,7 @@ def test_surplus(params: ParamsSurplus, all_cp_pv_charging_3p, all_cp_charging_3
expected_current_cp3=32,
expected_current_cp4=6,
expected_current_cp5=6,
expected_current_consumer7=0.5,
expected_raw_power_left=37520.0,
expected_surplus_power_left=3000,
expected_reserved_surplus=0,
Expand Down
3 changes: 2 additions & 1 deletion packages/control/algorithm/min_current.py
Original file line number Diff line number Diff line change
Expand Up @@ -21,7 +21,8 @@ def set_min_current(self) -> None:
preferenced_loads_groups = get_grouped_loads_by_mode_and_counter(CONSIDERED_CHARGE_MODES_MIN_CURRENT,
f"counter{counter.num}")
for preferenced_loads in preferenced_loads_groups:
log.info(f"Zähler {counter.num}, Verbraucher {filtered_loads_to_str(preferenced_loads)}")
if len(preferenced_loads) > 0:
log.info(f"Zähler {counter.num}, Verbraucher {filtered_loads_to_str(preferenced_loads)}")
common.update_raw_data(preferenced_loads, diff_to_zero=True)
while len(preferenced_loads):
load = preferenced_loads[0]
Expand Down
3 changes: 2 additions & 1 deletion packages/control/algorithm/surplus_controlled.py
Original file line number Diff line number Diff line change
Expand Up @@ -52,7 +52,8 @@ def _set(self,
feed_in_yield: int,
counter: Counter) -> None:
for loads in preferenced_loads_groups:
log.info(f"Zähler {counter.num}, Verbraucher {filtered_loads_to_str(loads)}")
if len(loads) > 0:
log.info(f"Zähler {counter.num}, Verbraucher {filtered_loads_to_str(loads)}")
common.update_raw_data(loads, surplus=True)
while len(loads):
load = loads[0]
Expand Down
2 changes: 2 additions & 0 deletions packages/control/consumer/consumer.py
Original file line number Diff line number Diff line change
Expand Up @@ -61,6 +61,8 @@ def update(self):
self.is_switch_interval_elapsed()
min_current, required_current, message, mode, submode = self.get_parameter()
self.set_mode_changed(submode, mode)
if self.chargemode_changed or self.submode_changed:
data.data.counter_all_data.get_evu_counter().reset_switch_on_off(self)
self.set_control_parameter(min_current, required_current,
self.data.config.connected_phases, submode, mode)
self.set_state_and_log(message)
Expand Down
55 changes: 32 additions & 23 deletions packages/control/counter.py
Original file line number Diff line number Diff line change
Expand Up @@ -320,28 +320,31 @@ def _get_switch_on_texts(self, load: Load) -> SwitchOnTexts:
return self.SWITCH_ON_TEXTS_CP
return self.SWITCH_ON_TEXTS_CONSUMER

def calc_switch_on_power(self, load: Load) -> Tuple[float, float]:
def calc_switch_on_power(self, switch_on_threshold: float) -> Tuple[float, float]:
surplus = self.calc_raw_surplus() - self.data.set.reserved_surplus
control_parameter = load.data.control_parameter
surplus_config = data.data.general_data.data.chargemode_config.surplus

if surplus_config.feed_in_limit:
threshold = surplus_config.feed_in_yield
else:
threshold = surplus_config.vehicle.switch_on_threshold*control_parameter.phases
threshold = switch_on_threshold

return surplus, threshold

def get_pv_config_py_load(self, load: Load) -> Tuple[float, float, bool]:
def get_pv_config_py_load(self, load: Load) -> Tuple[float, float, float]:
surplus_config = data.data.general_data.data.chargemode_config.surplus
if isinstance(load, Chargepoint):
switch_on_delay = data.data.general_data.data.chargemode_config.surplus.vehicle.switch_on_delay
switch_on_threshold = data.data.general_data.data.chargemode_config.surplus.vehicle.switch_on_threshold
control_parameter = load.data.control_parameter
switch_on_delay = surplus_config.vehicle.switch_on_delay
switch_on_threshold = surplus_config.vehicle.switch_on_threshold * control_parameter.phases
power_to_reserve = surplus_config.vehicle.switch_on_threshold*control_parameter.phases
else:
switch_on_delay = data.data.general_data.data.chargemode_config.surplus.consumer.switch_on_delay
switch_on_delay = surplus_config.consumer.switch_on_delay
switch_on_threshold = (load.data.control_parameter.required_current *
230 *
load.data.control_parameter.phases)
feed_in_limit = data.data.general_data.data.chargemode_config.surplus.feed_in_limit
return switch_on_delay, switch_on_threshold, feed_in_limit
power_to_reserve = switch_on_threshold
return switch_on_delay, switch_on_threshold, power_to_reserve

def switch_on_threshold_reached(self, load: Load) -> None:
try:
Expand All @@ -350,10 +353,9 @@ def switch_on_threshold_reached(self, load: Load) -> None:
control_parameter = load.data.control_parameter
surplus_config = data.data.general_data.data.chargemode_config.surplus
timestamp_switch_on_off = control_parameter.timestamp_switch_on_off
switch_on_delay, switch_on_threshold, feed_in_limit = self.get_pv_config_py_load(load)
switch_on_delay, switch_on_threshold, power_to_reserve = self.get_pv_config_py_load(load)

surplus, threshold = self.calc_switch_on_power(load)
power_to_reserve = surplus_config.vehicle.switch_on_threshold*control_parameter.phases
surplus, threshold = self.calc_switch_on_power(switch_on_threshold)
if control_parameter.state == ChargepointState.SWITCH_ON_DELAY:
# Wurde die Einschaltschwelle erreicht? Reservierte Leistung aus all_surplus herausrechnen,
# da diese Leistung ja schon reserviert wurde, als die Einschaltschwelle erreicht wurde.
Expand Down Expand Up @@ -397,7 +399,7 @@ def switch_on_timer_expired(self, load: Load) -> None:
try:
msg = None
texts = self._get_switch_on_texts(load)
switch_on_delay, switch_on_threshold, _ = self.get_pv_config_py_load(load)
switch_on_delay, _, power_to_reserve = self.get_pv_config_py_load(load)
control_parameter = load.data.control_parameter
# Timer ist noch nicht abgelaufen
if timecheck.check_timestamp(control_parameter.timestamp_switch_on_off,
Expand All @@ -407,7 +409,7 @@ def switch_on_timer_expired(self, load: Load) -> None:
# Timer abgelaufen
else:
control_parameter.timestamp_switch_on_off = None
self.data.set.reserved_surplus -= switch_on_threshold*control_parameter.phases
self.data.set.reserved_surplus -= power_to_reserve
msg = texts.expired
control_parameter.state = ChargepointState.WAIT_FOR_USING_PHASES

Expand Down Expand Up @@ -581,22 +583,29 @@ def switch_off_check_threshold(self, load: Load) -> bool:
load.set_state_and_log(msg)
return charge

def reset_switch_on_off(self, chargepoint: Chargepoint):
def reset_switch_on_off(self, load: Load):
try:
if chargepoint.data.control_parameter.timestamp_switch_on_off is not None:
chargepoint.data.control_parameter.timestamp_switch_on_off = None
if load.data.control_parameter.timestamp_switch_on_off is not None:
load.data.control_parameter.timestamp_switch_on_off = None
evu_counter = data.data.counter_all_data.get_evu_counter()
# Wenn bereits geladen wird, lief die Abschaltverzögerung -> Leistung, die nach Abschalten frei
# geworden wäre, nicht mehr zum zur Verfügung stehenden Überschuss zählen.
# Wenn nicht geladen wird, reservierte Leistung freigeben.
surplus_config = data.data.general_data.data.chargemode_config.surplus
if not chargepoint.data.get.charge_state:
evu_counter.data.set.reserved_surplus -= (surplus_config.vehicle.switch_on_threshold
* chargepoint.data.set.phases_to_use)
if isinstance(load, Chargepoint):
if not load.data.get.charge_state:
threshold = surplus_config.vehicle.switch_on_threshold * load.data.set.phases_to_use
else:
threshold = surplus_config.vehicle.switch_on_threshold * load.data.control_parameter.phases
else:
threshold = (load.data.control_parameter.required_current *
230 *
load.data.control_parameter.phases)
if not load.data.get.charge_state:
evu_counter.data.set.reserved_surplus -= threshold
else:
evu_counter.data.set.released_surplus -= (surplus_config.vehicle.switch_on_threshold
* chargepoint.data.control_parameter.phases)
chargepoint.data.control_parameter.state = ChargepointState.NO_CHARGING_ALLOWED
evu_counter.data.set.released_surplus -= threshold
load.data.control_parameter.state = ChargepointState.NO_CHARGING_ALLOWED
except Exception:
log.exception("Fehler im allgemeinen PV-Modul")

Expand Down