6 changes: 2 additions & 4 deletions packages/modules/devices/solakon/solakon_one/bat.py
Original file line number Diff line number Diff line change
Expand Up @@ -32,10 +32,8 @@ def initialize(self) -> None:
def update(self) -> None:
unit = self.component_config.configuration.modbus_id

# Reg 39134 AC Leistung am Stecker, Batterie aus dem Netz aufladen hat positive Werte,
# Leistung aus der Batterie und/oder aus PV ins Netz abgeben hat negative Werte
# Reg 39237 Battery Combined Power
power = self.client.read_holding_registers(39237, ModbusDataType.INT_32, unit=unit)
# Reg 39230 Battery Power, laut Hersteller-Doku positiv beim Laden, negativ beim Entladen
power = self.client.read_holding_registers(39230, ModbusDataType.INT_32, unit=unit)
Comment thread
seaspotter marked this conversation as resolved.
Resolved
# SoC Ladezustand der Batterie in %
soc = self.client.read_holding_registers(39424, ModbusDataType.INT_16, unit=unit)
# gesamte DC Ladung der Batterie in Wh
Expand Down
17 changes: 17 additions & 0 deletions packages/modules/devices/solakon/solakon_one/config.py
Original file line number Diff line number Diff line change
Expand Up @@ -58,3 +58,20 @@ def __init__(self,
configuration: SolakonOneInverterConfiguration = None,
**kwargs) -> None:
super().__init__(name, type, id, configuration or SolakonOneInverterConfiguration(), **kwargs)


@auto_str
class SolakonOneCounterConfiguration:
def __init__(self, modbus_id: int = 1):
self.modbus_id = modbus_id


@auto_str
class SolakonOneCounterSetup(ComponentSetup[SolakonOneCounterConfiguration]):
def __init__(self,
name: str = "Solakon One Zähler",
type: str = "counter",
id: int = 0,
configuration: SolakonOneCounterConfiguration = None,
**kwargs) -> None:
super().__init__(name, type, id, configuration or SolakonOneCounterConfiguration(), **kwargs)
50 changes: 50 additions & 0 deletions packages/modules/devices/solakon/solakon_one/counter.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,50 @@
#!/usr/bin/env python3
from typing import TypedDict, Any

from modules.common.abstract_device import AbstractCounter
from modules.common.component_state import CounterState
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType, ModbusTcpClient_
from modules.common.store import get_component_value_store
from modules.devices.solakon.solakon_one.config import SolakonOneCounterSetup
from modules.common.utils.peak_filter import PeakFilter
from modules.common.component_type import ComponentType


class KwargsDict(TypedDict):
client: ModbusTcpClient_


class SolakonOneCounter(AbstractCounter):
def __init__(self, component_config: SolakonOneCounterSetup, **kwargs: Any) -> None:
self.component_config = component_config
self.kwargs: KwargsDict = kwargs

def initialize(self) -> None:
self.client: ModbusTcpClient_ = self.kwargs['client']
self.store = get_component_value_store(self.component_config.type, self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))
self.peak_filter = PeakFilter(ComponentType.COUNTER, self.component_config.id, self.fault_state)

def update(self) -> None:
unit = self.component_config.configuration.modbus_id

# Reg 39134 AC Leistung am Stecker (Grid Information laut Hersteller-Doku), Bezug hat positive Werte,
# Einspeisung hat negative Werte
power = self.client.read_holding_registers(39134, ModbusDataType.INT_32, unit=unit) * -1
Comment thread
seaspotter marked this conversation as resolved.
Resolved

# Gesamte Netzeinspeisung/-bezug in Wh
exported = self.client.read_holding_registers(39621, ModbusDataType.UINT_32, unit=unit) * 10
imported = self.client.read_holding_registers(39625, ModbusDataType.UINT_32, unit=unit) * 10

imported, exported = self.peak_filter.check_values(power, imported, exported)
counter_state = CounterState(
power=power,
imported=imported,
exported=exported
)
self.store.set(counter_state)


component_descriptor = ComponentDescriptor(configuration_factory=SolakonOneCounterSetup)
12 changes: 9 additions & 3 deletions packages/modules/devices/solakon/solakon_one/device.py
Original file line number Diff line number Diff line change
Expand Up @@ -7,8 +7,10 @@
from modules.common.configurable_device import ConfigurableDevice, ComponentFactoryByType, MultiComponentUpdater
from modules.common.modbus import ModbusTcpClient_
from modules.devices.solakon.solakon_one.bat import SolakonOneBat
from modules.devices.solakon.solakon_one.counter import SolakonOneCounter
from modules.devices.solakon.solakon_one.inverter import SolakonOneInverter
from modules.devices.solakon.solakon_one.config import SolakonOne, SolakonOneBatSetup, SolakonOneInverterSetup
from modules.devices.solakon.solakon_one.config import (SolakonOne, SolakonOneBatSetup, SolakonOneCounterSetup,
SolakonOneInverterSetup)

log = logging.getLogger(__name__)

Expand All @@ -20,9 +22,12 @@ def create_bat_component(component_config: SolakonOneBatSetup):
return SolakonOneBat(component_config=component_config, client=client)

def create_inverter_component(component_config: SolakonOneInverterSetup):
return SolakonOneInverter(component_config=component_config, client=client)
return SolakonOneInverter(component_config=component_config, client=client, device_id=device_config.id)

def update_components(components: Iterable[Union[SolakonOneBat, SolakonOneInverter]]):
def create_counter_component(component_config: SolakonOneCounterSetup):
return SolakonOneCounter(component_config=component_config, client=client)

def update_components(components: Iterable[Union[SolakonOneBat, SolakonOneInverter, SolakonOneCounter]]):
with client:
for component in components:
with SingleComponentUpdateContext(component.fault_state):
Expand All @@ -38,6 +43,7 @@ def initializer():
component_factory=ComponentFactoryByType(
bat=create_bat_component,
inverter=create_inverter_component,
counter=create_counter_component,
),
component_updater=MultiComponentUpdater(update_components)
)
Expand Down
16 changes: 9 additions & 7 deletions packages/modules/devices/solakon/solakon_one/inverter.py
Original file line number Diff line number Diff line change
Expand Up @@ -6,6 +6,7 @@
from modules.common.component_type import ComponentDescriptor
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.modbus import ModbusDataType, ModbusTcpClient_
from modules.common.simcount import SimCounter
from modules.common.store import get_component_value_store
from modules.devices.solakon.solakon_one.config import SolakonOneInverterSetup
from modules.common.utils.peak_filter import PeakFilter
Expand All @@ -14,6 +15,7 @@

class KwargsDict(TypedDict):
client: ModbusTcpClient_
device_id: int


class SolakonOneInverter(AbstractInverter):
Expand All @@ -23,20 +25,20 @@ def __init__(self, component_config: SolakonOneInverterSetup, **kwargs: Any) ->

def initialize(self) -> None:
self.client: ModbusTcpClient_ = self.kwargs['client']
self.sim_counter = SimCounter(
self.kwargs['device_id'], self.component_config.id, self.component_config.type)
self.store = get_component_value_store(self.component_config.type, self.component_config.id)
self.fault_state = FaultState(ComponentInfo.from_component_config(self.component_config))
self.peak_filter = PeakFilter(ComponentType.INVERTER, self.component_config.id, self.fault_state)

def update(self) -> None:
unit = self.component_config.configuration.modbus_id

# Reg 39134 AC Leistung am Stecker, Batterie aus dem Heimnetz aufladen hat positive Werte,
# Leistung aus der Batterie und/oder aus PV ins Heimnetz abgeben hat negative Werte
power = self.client.read_holding_registers(39134, ModbusDataType.INT_32, unit=unit) * -1

# Gesamte Energie am Wechselrichter in Wh
exported = self.client.read_holding_registers(39621, ModbusDataType.UINT_32, unit=unit) * 10
imported = self.client.read_holding_registers(39625, ModbusDataType.UINT_32, unit=unit) * 10
# Gesamte DC PV Leistung aller vier MPPT in W
power = self.client.read_holding_registers(39118, ModbusDataType.INT_32, unit=unit) * -1
Comment thread
seaspotter marked this conversation as resolved.
Resolved
# Gesamte DC PV Produktion in Wh
exported = self.client.read_holding_registers(39601, ModbusDataType.UINT_32, unit=unit) * 10
imported, _ = self.sim_counter.sim_count(power)
Comment thread
seaspotter marked this conversation as resolved.
Resolved
Comment thread
seaspotter marked this conversation as resolved.
Resolved
Comment thread
seaspotter marked this conversation as resolved.
Resolved

imported, exported = self.peak_filter.check_values(power, imported, exported)