Phasenumschaltung series2: auf Zählerstrom 0 A und EVSE-Status B warten (#4289) #4330
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
base: master
Are you sure you want to change the base?
Changes from all commits
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -1,4 +1,5 @@ | ||
| import logging | ||
| from typing import List, Optional | ||
|
|
||
| import time | ||
| from helpermodules.broker import BrokerClient | ||
|
|
@@ -9,6 +10,7 @@ | |
| from modules.common.abstract_chargepoint import AbstractChargepoint | ||
| from modules.common.component_context import SingleComponentUpdateContext | ||
| from modules.common.component_state import ChargepointState | ||
| from modules.common.evse import EvseStatusCode | ||
| from modules.common.fault_state import ComponentInfo, FaultState | ||
| from modules.common.store import get_internal_chargepoint_value_store, get_chargepoint_value_store | ||
| from modules.internal_chargepoint_handler.clients import ClientHandler | ||
|
|
@@ -141,27 +143,69 @@ def store_state(chargepoint_state: ChargepointState) -> None: | |
| self.old_chargepoint_state = chargepoint_state | ||
| return chargepoint_state | ||
|
|
||
| # Issue #4289: Vor dem CP-Trennen muss der Zähler 0 A zeigen UND die EVSE das Fahrzeug in State A/B melden | ||
| # (Statusregister 1002 = 1/2). Der EVSE-Sollwert (Register 1000) taugt nicht als Kriterium, er steht | ||
| # sofort nach set_current(0) auf 0 (#3326). Ein einzelner Busfehler beim Rücklesen bricht nicht ab; | ||
| # erst ohne Bestätigung im Zeitfenster wird abgebrochen (Exception -> FaultState, keine GPIO-Aktion). | ||
| PHASE_SWITCH_CURRENT_THRESHOLD_A = 0.5 # MPM3PM zeigt bei offenem EV-Schütz 0,0 A, SDM/B23 rauschen | ||
| PHASE_SWITCH_METER_POLLS = 20 # 20 x (0,5 s + Lesezeit) = 10-20 s | ||
|
|
||
| @classmethod | ||
| def _vehicle_stopped_charging(cls, currents: Optional[List[Optional[float]]], evse_state: int) -> bool: | ||
| # Status 3/4 = State C/D (lädt), 5 = Fehler: beides keine Bestätigung | ||
| if evse_state not in (EvseStatusCode.READY, EvseStatusCode.EV_PRESENT): | ||
| return False | ||
| if currents is None: # kein Zähler vorhanden, nur der EVSE-Status zählt | ||
| return True | ||
| # jede Phase braucht einen gültigen Messwert unter der Schwelle; None (z. B. NaN vom B23) zählt nicht als 0 A, | ||
| # Vorzeichen (Zähler verkehrt herum eingebaut) spielt keine Rolle | ||
| return len(currents) == 3 and all( | ||
| c is not None and abs(c) < cls.PHASE_SWITCH_CURRENT_THRESHOLD_A for c in currents) | ||
|
|
||
| def perform_phase_switch(self, phases_to_use: int) -> None: | ||
| gpio_cp, gpio_relay = self._client.get_pins_phase_switch(phases_to_use) | ||
| evse = self._client.evse_client | ||
| meter = self._client.meter_client | ||
| num = self.local_charge_point_num | ||
| start = time.monotonic() | ||
| with SingleComponentUpdateContext(self.fault_state, update_always=False, reraise=True): | ||
| evse.set_current(0) | ||
| for _ in range(20): # poll up to 10s (20 × 0.5s) for EVSE to confirm 0 A | ||
| _, _, evse_current = evse.get_plug_charge_state() | ||
| if evse_current == 0: | ||
| break | ||
| if meter is None: | ||
| log.warning(f"Phasenumschaltung LP{num}: kein Zähler gefunden, es wird nur der EVSE-Status geprüft.") | ||
| evse.set_current(0) # Schreibfehler -> Abbruch: ohne 0-A-Vorgabe wird nicht geschaltet (#3326) | ||
| for poll in range(1, self.PHASE_SWITCH_METER_POLLS + 1): | ||
| try: | ||
| # Status aus dieser Lesung verwenden, nicht aus einem geteilten Attribut: der reguläre | ||
| # Zyklus liest die EVSE parallel und könnte sonst einen älteren Wert hinterlassen | ||
| state = evse.get_state_number() | ||
| currents = meter.get_counter_state().currents if meter is not None else None | ||
| log.debug(f"Phasenumschaltung LP{num}: Durchlauf {poll}, Ströme {currents} A, EVSE-Status {state}") | ||
| if self._vehicle_stopped_charging(currents, state): | ||
| log.warning(f"Phasenumschaltung LP{num}: 0 A und EVSE-Status {state} nach {poll} Durchläufen" | ||
| f" / {time.monotonic() - start:.1f} s bestätigt, Ströme {currents} A.") | ||
| break | ||
| except Exception as e: | ||
| # einzelner Busfehler (EVSE und Zähler am selben RS485-Bus): weiter pollen | ||
| log.warning(f"Phasenumschaltung LP{num}: Rücklesen fehlgeschlagen ({e}), weiter.") | ||
| time.sleep(0.5) | ||
| evse.set_current(0) | ||
| try: | ||
| evse.set_current(0) | ||
| except Exception as e: | ||
| log.warning(f"Phasenumschaltung LP{num}: 0 A setzen fehlgeschlagen ({e}), weiter.") | ||
| else: | ||
| raise Exception("Ladung konnte nicht gestoppt werden - Phasenumschaltung abgebrochen.") | ||
| GPIO.output(gpio_cp, GPIO.HIGH) # CP off | ||
| GPIO.output(gpio_relay, GPIO.HIGH) # 3 on/off | ||
| time.sleep(5) | ||
| GPIO.output(gpio_relay, GPIO.LOW) # 3 on/off | ||
| time.sleep(5) | ||
| GPIO.output(gpio_cp, GPIO.LOW) # CP on | ||
| raise Exception("Fahrzeug hat die Ladung nicht beendet (Zählerstrom > 0 oder EVSE-Status C)" | ||
| " - Phasenumschaltung abgebrochen.") | ||
| try: | ||
| GPIO.output(gpio_cp, GPIO.HIGH) # CP off | ||
| GPIO.output(gpio_relay, GPIO.HIGH) # 3 on/off | ||
| time.sleep(5) | ||
| GPIO.output(gpio_relay, GPIO.LOW) # 3 on/off | ||
| time.sleep(5) | ||
| finally: | ||
| GPIO.output(gpio_cp, GPIO.LOW) # CP on - in jedem Fall wieder verbinden (#4037) | ||
|
Comment on lines
+199
to
+204
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. 🟡 Medium · CP interruption overlaps phase switching When a single update requests both a phase switch and a positive CP-interruption duration, Serialize the two operations or explicitly coordinate CP ownership so neither thread can change CP while the other operation is active. Prompt for AI agentsIn `packages/modules/internal_chargepoint_handler/chargepoint_module.py` at lines 186-191:
**CP interruption overlaps phase switching**
When a single update requests both a phase switch and a positive CP-interruption duration, `UpdateState.update_state()` starts the phase-switch thread and then can start a CP-interruption thread in the same update. Both threads drive the same CP pin; the phase-switch `finally` can reconnect the vehicle while the interruption is still active, and the interruption can likewise change CP during relay switching, leaving the interruption or phase-switch operation in an unintended state.
Serialize the two operations or explicitly coordinate CP ownership so neither thread can change CP while the other operation is active. |
||
| time.sleep(1) | ||
| self.old_phases_in_use = phases_to_use | ||
| log.warning(f"Phasenumschaltung LP{num}: auf {phases_to_use} Phasen umgeschaltet " | ||
| f"({time.monotonic() - start:.1f} s gesamt).") | ||
|
|
||
| def perform_cp_interruption(self, duration: int) -> None: | ||
| gpio_cp = self._client.get_pins_cp_interruption() | ||
|
|
||
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,94 @@ | ||
| from typing import List, Optional | ||
| from unittest.mock import MagicMock | ||
|
|
||
| import pytest | ||
|
|
||
| from modules.internal_chargepoint_handler import chargepoint_module | ||
| from modules.internal_chargepoint_handler.chargepoint_module import ChargepointModule | ||
|
|
||
|
|
||
| @pytest.mark.parametrize( | ||
| "currents, evse_state, expected", | ||
| [ | ||
| pytest.param([0.0, 0.0, 0.0], 2, True, id="0 A, State B"), | ||
| pytest.param([0.0, 0.0, 0.0], 1, True, id="0 A, State A (abgesteckt)"), | ||
| pytest.param([0.0, 0.857, 0.013], 2, False, id="Restlast auf L2 bei State B"), | ||
| pytest.param([15.6, 9.7, 15.9], 3, False, id="Last, State C"), | ||
| pytest.param([0.0, 0.0, 0.0], 3, False, id="0 A, aber noch State C"), | ||
| pytest.param([0.0, 0.0, 0.0], 4, False, id="0 A, State D"), | ||
| pytest.param([0.0, 0.0, 0.0], 5, False, id="EVSE-Fehler"), | ||
| pytest.param([None, None, None], 2, False, id="keine Messwerte (B23 NaN)"), | ||
| pytest.param([0.0, None, 0.0], 2, False, id="eine Phase ohne Messwert"), | ||
| pytest.param([-0.2, 0.0, 0.0], 2, True, id="Rauschen negativ"), | ||
| pytest.param([-3.0, 0.0, 0.0], 2, False, id="Strom negativ (Zähler verdreht)"), | ||
| pytest.param(None, 2, True, id="kein Zähler, State B"), | ||
| pytest.param(None, 3, False, id="kein Zähler, State C"), | ||
| ]) | ||
| def test_vehicle_stopped_charging(currents: Optional[List[Optional[float]]], evse_state: int, expected: bool): | ||
| assert ChargepointModule._vehicle_stopped_charging(currents, evse_state) == expected | ||
|
|
||
|
|
||
| @pytest.fixture | ||
| def module(monkeypatch) -> ChargepointModule: | ||
| monkeypatch.setattr("time.sleep", lambda seconds: None) | ||
| monkeypatch.setattr(chargepoint_module, "GPIO", MagicMock(), raising=False) | ||
| cp = ChargepointModule.__new__(ChargepointModule) | ||
| cp.local_charge_point_num = 0 | ||
| cp.old_phases_in_use = 3 | ||
| cp.fault_state = MagicMock() | ||
| cp.fault_state.component_info.name = "Interner Ladepunkt 0" | ||
| cp._client = MagicMock() | ||
| cp._client.get_pins_phase_switch.return_value = (7, 11) | ||
| return cp | ||
|
|
||
|
|
||
| def counter_state(currents): | ||
| state = MagicMock() | ||
| state.currents = currents | ||
| return state | ||
|
|
||
|
|
||
| def test_perform_phase_switch_waits_for_meter_and_evse(module: ChargepointModule): | ||
| module._client.evse_client.get_state_number.side_effect = [3, 2, 2] | ||
| module._client.meter_client.get_counter_state.side_effect = [ | ||
| counter_state([15.6, 9.7, 15.9]), counter_state([0.0, 0.857, 0.013]), counter_state([0.0, 0.0, 0.0])] | ||
|
|
||
| module.perform_phase_switch(1) | ||
|
|
||
| assert module._client.evse_client.get_state_number.call_count == 3 | ||
| assert module._client.evse_client.set_current.call_count == 3 # einmal vorab, je Wartedurchlauf erneut | ||
| assert chargepoint_module.GPIO.output.call_count == 4 | ||
| assert module.old_phases_in_use == 1 | ||
|
|
||
|
|
||
| def test_perform_phase_switch_continues_after_read_error(module: ChargepointModule): | ||
| module._client.evse_client.get_state_number.side_effect = [Exception("No response received"), 2] | ||
| module._client.meter_client.get_counter_state.return_value = counter_state([0.0, 0.0, 0.0]) | ||
|
|
||
| module.perform_phase_switch(1) | ||
|
|
||
| assert chargepoint_module.GPIO.output.call_count == 4 | ||
| assert module.old_phases_in_use == 1 | ||
|
|
||
|
|
||
| def test_perform_phase_switch_aborts_without_confirmation(module: ChargepointModule, monkeypatch): | ||
| monkeypatch.setattr(ChargepointModule, "PHASE_SWITCH_METER_POLLS", 3) | ||
| module._client.evse_client.get_state_number.return_value = 3 | ||
| module._client.meter_client.get_counter_state.return_value = counter_state([15.6, 9.7, 15.9]) | ||
|
|
||
| with pytest.raises(Exception, match="Phasenumschaltung abgebrochen"): | ||
| module.perform_phase_switch(1) | ||
|
|
||
| assert module._client.evse_client.get_state_number.call_count == 3 | ||
| chargepoint_module.GPIO.output.assert_not_called() | ||
| assert module.old_phases_in_use == 3 | ||
|
|
||
|
|
||
| def test_perform_phase_switch_without_meter_uses_evse_state(module: ChargepointModule): | ||
| module._client.meter_client = None | ||
| module._client.evse_client.get_state_number.side_effect = [3, 2] | ||
|
|
||
| module.perform_phase_switch(1) | ||
|
|
||
| assert chargepoint_module.GPIO.output.call_count == 4 | ||
| assert module.old_phases_in_use == 1 |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
🟡 Medium · Relay failure leaves phase state inconsistent
When a GPIO operation or delay raises after the relay has changed state, the
finallyblock reconnects CP without ensuring the relay is reset, whileold_phases_in_useremains unchanged; charging can resume with the hardware phase configuration different from the recorded configuration.On relay-sequence errors, restore or confirm the relay configuration and synchronize
old_phases_in_usebefore reconnecting CP.Prompt for AI agents