12 changes: 11 additions & 1 deletion packages/modules/common/evse.py
Original file line number Diff line number Diff line change
Expand Up @@ -48,14 +48,24 @@ def __init__(self, modbus_id: int, client: modbus.ModbusSerialClient_) -> None:
self._precise_current = self.is_precise_current_active()
self.evse_current = 0

def get_plug_charge_state(self) -> Tuple[bool, bool, float]:
def _read_state(self) -> int:
"""Liest Soll-Strom (Register 1000) und Status (Register 1002), gibt den Rohstatus zurück."""
time.sleep(0.1)
raw_set_current, _, state_number = self.client.read_holding_registers(
1000, [ModbusDataType.UINT_16]*3, unit=self.id)
# remove leading zeros
self.evse_current = int(raw_set_current)
log.debug("Gesetzte Stromstärke EVSE: "+str(self.evse_current) +
", Status: "+str(state_number)+", Modbus-ID: "+str(self.id))
return int(state_number)

def get_state_number(self) -> int:
"""Rohstatus (EvseStatusCode-Nummer) dieser Lesung, z. B. für die Phasenumschaltung:
1 = State A, 2 = State B, 3/4 = State C/D (Fahrzeug lädt), 5 = Fehler."""
return self._read_state()

def get_plug_charge_state(self) -> Tuple[bool, bool, float]:
state_number = self._read_state()
state = EvseStatusCode(state_number)
if state == EvseStatusCode.FAILURE:
raise ValueError("Unbekannter Zustand der EVSE: State " +
Expand Down
70 changes: 57 additions & 13 deletions packages/modules/internal_chargepoint_handler/chargepoint_module.py
Original file line number Diff line number Diff line change
@@ -1,4 +1,5 @@
import logging
from typing import List, Optional

import time
from helpermodules.broker import BrokerClient
Expand All @@ -9,6 +10,7 @@
from modules.common.abstract_chargepoint import AbstractChargepoint
from modules.common.component_context import SingleComponentUpdateContext
from modules.common.component_state import ChargepointState
from modules.common.evse import EvseStatusCode
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.store import get_internal_chargepoint_value_store, get_chargepoint_value_store
from modules.internal_chargepoint_handler.clients import ClientHandler
Expand Down Expand Up @@ -141,27 +143,69 @@ def store_state(chargepoint_state: ChargepointState) -> None:
self.old_chargepoint_state = chargepoint_state
return chargepoint_state

# Issue #4289: Vor dem CP-Trennen muss der Zähler 0 A zeigen UND die EVSE das Fahrzeug in State A/B melden
# (Statusregister 1002 = 1/2). Der EVSE-Sollwert (Register 1000) taugt nicht als Kriterium, er steht
# sofort nach set_current(0) auf 0 (#3326). Ein einzelner Busfehler beim Rücklesen bricht nicht ab;
# erst ohne Bestätigung im Zeitfenster wird abgebrochen (Exception -> FaultState, keine GPIO-Aktion).
PHASE_SWITCH_CURRENT_THRESHOLD_A = 0.5 # MPM3PM zeigt bei offenem EV-Schütz 0,0 A, SDM/B23 rauschen
PHASE_SWITCH_METER_POLLS = 20 # 20 x (0,5 s + Lesezeit) = 10-20 s

@classmethod
def _vehicle_stopped_charging(cls, currents: Optional[List[Optional[float]]], evse_state: int) -> bool:
# Status 3/4 = State C/D (lädt), 5 = Fehler: beides keine Bestätigung
if evse_state not in (EvseStatusCode.READY, EvseStatusCode.EV_PRESENT):
return False
if currents is None: # kein Zähler vorhanden, nur der EVSE-Status zählt
return True
# jede Phase braucht einen gültigen Messwert unter der Schwelle; None (z. B. NaN vom B23) zählt nicht als 0 A,
# Vorzeichen (Zähler verkehrt herum eingebaut) spielt keine Rolle
return len(currents) == 3 and all(
c is not None and abs(c) < cls.PHASE_SWITCH_CURRENT_THRESHOLD_A for c in currents)

def perform_phase_switch(self, phases_to_use: int) -> None:
gpio_cp, gpio_relay = self._client.get_pins_phase_switch(phases_to_use)
evse = self._client.evse_client
meter = self._client.meter_client
num = self.local_charge_point_num
start = time.monotonic()
with SingleComponentUpdateContext(self.fault_state, update_always=False, reraise=True):
evse.set_current(0)
for _ in range(20): # poll up to 10s (20 × 0.5s) for EVSE to confirm 0 A
_, _, evse_current = evse.get_plug_charge_state()
if evse_current == 0:
break
if meter is None:
log.warning(f"Phasenumschaltung LP{num}: kein Zähler gefunden, es wird nur der EVSE-Status geprüft.")
evse.set_current(0) # Schreibfehler -> Abbruch: ohne 0-A-Vorgabe wird nicht geschaltet (#3326)
for poll in range(1, self.PHASE_SWITCH_METER_POLLS + 1):
try:
# Status aus dieser Lesung verwenden, nicht aus einem geteilten Attribut: der reguläre
# Zyklus liest die EVSE parallel und könnte sonst einen älteren Wert hinterlassen
state = evse.get_state_number()
currents = meter.get_counter_state().currents if meter is not None else None
log.debug(f"Phasenumschaltung LP{num}: Durchlauf {poll}, Ströme {currents} A, EVSE-Status {state}")
if self._vehicle_stopped_charging(currents, state):
log.warning(f"Phasenumschaltung LP{num}: 0 A und EVSE-Status {state} nach {poll} Durchläufen"
f" / {time.monotonic() - start:.1f} s bestätigt, Ströme {currents} A.")
break
except Exception as e:
# einzelner Busfehler (EVSE und Zähler am selben RS485-Bus): weiter pollen
log.warning(f"Phasenumschaltung LP{num}: Rücklesen fehlgeschlagen ({e}), weiter.")
time.sleep(0.5)
evse.set_current(0)
try:
evse.set_current(0)
except Exception as e:
log.warning(f"Phasenumschaltung LP{num}: 0 A setzen fehlgeschlagen ({e}), weiter.")
else:
raise Exception("Ladung konnte nicht gestoppt werden - Phasenumschaltung abgebrochen.")
GPIO.output(gpio_cp, GPIO.HIGH) # CP off
GPIO.output(gpio_relay, GPIO.HIGH) # 3 on/off
time.sleep(5)
GPIO.output(gpio_relay, GPIO.LOW) # 3 on/off
time.sleep(5)
GPIO.output(gpio_cp, GPIO.LOW) # CP on
raise Exception("Fahrzeug hat die Ladung nicht beendet (Zählerstrom > 0 oder EVSE-Status C)"
" - Phasenumschaltung abgebrochen.")
try:
GPIO.output(gpio_cp, GPIO.HIGH) # CP off
GPIO.output(gpio_relay, GPIO.HIGH) # 3 on/off
time.sleep(5)
GPIO.output(gpio_relay, GPIO.LOW) # 3 on/off
time.sleep(5)
finally:
GPIO.output(gpio_cp, GPIO.LOW) # CP on - in jedem Fall wieder verbinden (#4037)
Comment on lines +199 to +204

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟡 Medium · Relay failure leaves phase state inconsistent

When a GPIO operation or delay raises after the relay has changed state, the finally block reconnects CP without ensuring the relay is reset, while old_phases_in_use remains unchanged; charging can resume with the hardware phase configuration different from the recorded configuration.

On relay-sequence errors, restore or confirm the relay configuration and synchronize old_phases_in_use before reconnecting CP.

Prompt for AI agents
In `packages/modules/internal_chargepoint_handler/chargepoint_module.py` at lines 186-191:

**Relay failure leaves phase state inconsistent**

When a GPIO operation or delay raises after the relay has changed state, the `finally` block reconnects CP without ensuring the relay is reset, while `old_phases_in_use` remains unchanged; charging can resume with the hardware phase configuration different from the recorded configuration.

On relay-sequence errors, restore or confirm the relay configuration and synchronize `old_phases_in_use` before reconnecting CP.

Comment on lines +199 to +204

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟡 Medium · CP interruption overlaps phase switching

When a single update requests both a phase switch and a positive CP-interruption duration, UpdateState.update_state() starts the phase-switch thread and then can start a CP-interruption thread in the same update. Both threads drive the same CP pin; the phase-switch finally can reconnect the vehicle while the interruption is still active, and the interruption can likewise change CP during relay switching, leaving the interruption or phase-switch operation in an unintended state.

Serialize the two operations or explicitly coordinate CP ownership so neither thread can change CP while the other operation is active.

Prompt for AI agents
In `packages/modules/internal_chargepoint_handler/chargepoint_module.py` at lines 186-191:

**CP interruption overlaps phase switching**

When a single update requests both a phase switch and a positive CP-interruption duration, `UpdateState.update_state()` starts the phase-switch thread and then can start a CP-interruption thread in the same update. Both threads drive the same CP pin; the phase-switch `finally` can reconnect the vehicle while the interruption is still active, and the interruption can likewise change CP during relay switching, leaving the interruption or phase-switch operation in an unintended state.

Serialize the two operations or explicitly coordinate CP ownership so neither thread can change CP while the other operation is active.

time.sleep(1)
self.old_phases_in_use = phases_to_use
log.warning(f"Phasenumschaltung LP{num}: auf {phases_to_use} Phasen umgeschaltet "
f"({time.monotonic() - start:.1f} s gesamt).")

def perform_cp_interruption(self, duration: int) -> None:
gpio_cp = self._client.get_pins_cp_interruption()
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,94 @@
from typing import List, Optional
from unittest.mock import MagicMock

import pytest

from modules.internal_chargepoint_handler import chargepoint_module
from modules.internal_chargepoint_handler.chargepoint_module import ChargepointModule


@pytest.mark.parametrize(
"currents, evse_state, expected",
[
pytest.param([0.0, 0.0, 0.0], 2, True, id="0 A, State B"),
pytest.param([0.0, 0.0, 0.0], 1, True, id="0 A, State A (abgesteckt)"),
pytest.param([0.0, 0.857, 0.013], 2, False, id="Restlast auf L2 bei State B"),
pytest.param([15.6, 9.7, 15.9], 3, False, id="Last, State C"),
pytest.param([0.0, 0.0, 0.0], 3, False, id="0 A, aber noch State C"),
pytest.param([0.0, 0.0, 0.0], 4, False, id="0 A, State D"),
pytest.param([0.0, 0.0, 0.0], 5, False, id="EVSE-Fehler"),
pytest.param([None, None, None], 2, False, id="keine Messwerte (B23 NaN)"),
pytest.param([0.0, None, 0.0], 2, False, id="eine Phase ohne Messwert"),
pytest.param([-0.2, 0.0, 0.0], 2, True, id="Rauschen negativ"),
pytest.param([-3.0, 0.0, 0.0], 2, False, id="Strom negativ (Zähler verdreht)"),
pytest.param(None, 2, True, id="kein Zähler, State B"),
pytest.param(None, 3, False, id="kein Zähler, State C"),
])
def test_vehicle_stopped_charging(currents: Optional[List[Optional[float]]], evse_state: int, expected: bool):
assert ChargepointModule._vehicle_stopped_charging(currents, evse_state) == expected


@pytest.fixture
def module(monkeypatch) -> ChargepointModule:
monkeypatch.setattr("time.sleep", lambda seconds: None)
monkeypatch.setattr(chargepoint_module, "GPIO", MagicMock(), raising=False)
cp = ChargepointModule.__new__(ChargepointModule)
cp.local_charge_point_num = 0
cp.old_phases_in_use = 3
cp.fault_state = MagicMock()
cp.fault_state.component_info.name = "Interner Ladepunkt 0"
cp._client = MagicMock()
cp._client.get_pins_phase_switch.return_value = (7, 11)
return cp


def counter_state(currents):
state = MagicMock()
state.currents = currents
return state


def test_perform_phase_switch_waits_for_meter_and_evse(module: ChargepointModule):
module._client.evse_client.get_state_number.side_effect = [3, 2, 2]
module._client.meter_client.get_counter_state.side_effect = [
counter_state([15.6, 9.7, 15.9]), counter_state([0.0, 0.857, 0.013]), counter_state([0.0, 0.0, 0.0])]

module.perform_phase_switch(1)

assert module._client.evse_client.get_state_number.call_count == 3
assert module._client.evse_client.set_current.call_count == 3 # einmal vorab, je Wartedurchlauf erneut
assert chargepoint_module.GPIO.output.call_count == 4
assert module.old_phases_in_use == 1


def test_perform_phase_switch_continues_after_read_error(module: ChargepointModule):
module._client.evse_client.get_state_number.side_effect = [Exception("No response received"), 2]
module._client.meter_client.get_counter_state.return_value = counter_state([0.0, 0.0, 0.0])

module.perform_phase_switch(1)

assert chargepoint_module.GPIO.output.call_count == 4
assert module.old_phases_in_use == 1


def test_perform_phase_switch_aborts_without_confirmation(module: ChargepointModule, monkeypatch):
monkeypatch.setattr(ChargepointModule, "PHASE_SWITCH_METER_POLLS", 3)
module._client.evse_client.get_state_number.return_value = 3
module._client.meter_client.get_counter_state.return_value = counter_state([15.6, 9.7, 15.9])

with pytest.raises(Exception, match="Phasenumschaltung abgebrochen"):
module.perform_phase_switch(1)

assert module._client.evse_client.get_state_number.call_count == 3
chargepoint_module.GPIO.output.assert_not_called()
assert module.old_phases_in_use == 3


def test_perform_phase_switch_without_meter_uses_evse_state(module: ChargepointModule):
module._client.meter_client = None
module._client.evse_client.get_state_number.side_effect = [3, 2]

module.perform_phase_switch(1)

assert chargepoint_module.GPIO.output.call_count == 4
assert module.old_phases_in_use == 1