An owner-entered car SoC is lost when the charger socket reconnects #1928

Open

Description

@frahlg

Follow-up from #1788, which #1848 settled: a socket drop or a missing hardware identity no longer ends Charge now.

One part was left open there. observeConnectionProof (go/internal/loadpoint/session_state.go, about lines 332–344 on master 83c2b24) still clears the SoC the owner entered when the socket reconnects. A target such as "Charge now to 80 %" then counts from PluginSoC instead of the value the owner typed.

Expected: a reconnect of the same charger and session keeps the owner-entered SoC. It is cleared only on unplug, another serial, a new session ID or a loadpoint config change, the same rules #1848 uses for the hold.

Test: the #1848 reconnect shape with an owner-entered SoC of 40 % and a target of 80 %; after the reconnect the session still reports 40 % as its start.

Not needed for stable.