5 changes: 5 additions & 0 deletions .changeset/charge-now-survives-restart.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,5 @@
---
"ftw": patch
---

Charge now keeps charging after an update or restart. Before, a restart turned it into a pause until someone pressed Start again. It still ends on Stop, when the car is unplugged or full, and a different car on the charger does not inherit it.
120 changes: 120 additions & 0 deletions go/internal/loadpoint/controller_hold_restart_test.go
Original file line number Diff line number Diff line change
@@ -0,0 +1,120 @@
package loadpoint

import (
"context"
"testing"
"time"
)

// bootController is one Core process over a state.db that outlives it.
func bootController(t *testing.T, store *sessionMemory, samples map[string]EVSample) (*Controller, *fakeSender) {
t.Helper()
m := NewManager()
m.Load([]Config{holdLoadpoint()})
m.SetSessionStore(store)
sender := &fakeSender{}
plan := PlanFunc(func(time.Time) (Directive, bool) { return Directive{}, false })
tel := TelemetryFunc(func(driver string) (EVSample, bool) { s, ok := samples[driver]; return s, ok })
c := NewController(m, plan, tel, sender.Send)
c.SetSiteFuse(SiteFuse{MaxAmps: 16, Voltage: 230, PhaseCnt: 3})
c.SetManualHoldSaver(func(id string, h ManualHold, cleared bool) {
if err := m.PersistManualHold(id, h, cleared); err != nil {
t.Error(err)
}
})
return c, sender
}

func tickWants(t *testing.T, c *Controller, sender *fakeSender, now time.Time, power float64, unconfirmed bool) {
t.Helper()
c.Tick(context.Background(), now)
if last, ok := lastSetCurrent(sender.calls); !ok || last.power != power {
t.Fatalf("commands=%+v, want latest power %v", sender.calls, power)
}
if st, _ := c.manager.State("garage"); st.ManualRestoreUnconfirmed != unconfirmed {
t.Fatalf("manual_restore_unconfirmed = %v, want %v", st.ManualRestoreUnconfirmed, unconfirmed)
}
}

// Charge now ends on Stop, unplug or a full car. A restart is none of them,
// even when the charger reports its identity before its session.
func TestChargeNowWaitsForSessionAfterRestart(t *testing.T) {
for _, reconnect := range []bool{false, true} {
store := &sessionMemory{data: map[string]string{}}
sample := EVSample{Connected: true, RequestActive: true, ConnectionGeneration: 1, DeviceID: "easee:A", SessionID: "session-1"}
samples := map[string]EVSample{"easee": sample}
c, sender := bootController(t, store, samples)
now := time.Now()
c.SetManualHold("garage", ManualHold{PowerW: 4140, Persistent: true})
tickWants(t, c, sender, now, 4140, false)

c, sender = bootController(t, store, samples)
sample.SessionID = ""
samples["easee"] = sample
tickWants(t, c, sender, now.Add(20*time.Second), 0, true)
if reconnect {
// A new socket is not a new car; only the session can tell.
sample.ConnectionGeneration = 2
samples["easee"] = sample
tickWants(t, c, sender, now.Add(21*time.Second), 0, true)
}
sample.SessionID = "session-1"
samples["easee"] = sample
tickWants(t, c, sender, now.Add(22*time.Second), 4140, false)
}
}

// Most chargers, OCPP included, never report a session ID. The same
// hardware still plugged in resumes at once; an unplug still ends it.
func TestChargeNowWithoutSessionIDResumesAfterRestart(t *testing.T) {
store := &sessionMemory{data: map[string]string{}}
sample := EVSample{Connected: true, RequestActive: true, ConnectionGeneration: 1, DeviceID: "rigco:OCPPSIM02"}
samples := map[string]EVSample{"easee": sample}
c, sender := bootController(t, store, samples)
now := time.Now()
c.SetManualHold("garage", ManualHold{PowerW: 4140, Persistent: true})
tickWants(t, c, sender, now, 4140, false)

// After a restart the charger connects before it reports its cable.
samples["easee"] = EVSample{ConnectionUnknown: true, ConnectionGeneration: 1}
c, sender = bootController(t, store, samples)
c.Tick(context.Background(), now.Add(20*time.Second))
samples["easee"] = sample
tickWants(t, c, sender, now.Add(21*time.Second), 4140, false)

sample.Connected = false
samples["easee"] = sample
c.Tick(context.Background(), now.Add(22*time.Second))
sample.Connected = true
samples["easee"] = sample
tickWants(t, c, sender, now.Add(23*time.Second), 0, false)
if h, ok := c.GetManualHold("garage", now); ok {
t.Fatalf("the next car inherited Charge now: %+v", h)
}
c, sender = bootController(t, store, samples)
tickWants(t, c, sender, now.Add(30*time.Second), 0, false)
if h, ok := c.GetManualHold("garage", now); ok {
t.Fatalf("Charge now returned after unplug and restart: %+v", h)
}
}

// A different session after a restart means the car changed while Core
// was down. It must not inherit the earlier Charge now.
func TestChargeNowDoesNotFollowAnotherSessionAfterRestart(t *testing.T) {
store := &sessionMemory{data: map[string]string{}}
sample := EVSample{Connected: true, RequestActive: true, DeviceID: "easee:A", SessionID: "session-1"}
samples := map[string]EVSample{"easee": sample}
c, sender := bootController(t, store, samples)
now := time.Now()
c.SetManualHold("garage", ManualHold{PowerW: 4140, Persistent: true})
tickWants(t, c, sender, now, 4140, false)

c, sender = bootController(t, store, samples)
sample.SessionID = ""
samples["easee"] = sample
tickWants(t, c, sender, now.Add(20*time.Second), 0, true)
sample.SessionID = "session-2"
samples["easee"] = sample
tickWants(t, c, sender, now.Add(21*time.Second), 0, true)
tickWants(t, c, sender, now.Add(22*time.Second), 0, true)
}
5 changes: 4 additions & 1 deletion go/internal/loadpoint/controller_hold_restore.go
Original file line number Diff line number Diff line change
Expand Up @@ -61,8 +61,11 @@ func (c *Controller) restoreManualHoldForSession(id string) {
}
// A Start before the first hardware reading binds here. Once bound, a
// different hardware/session/config generation must not inherit its power.
// A restore still waiting for proof has no power to inherit; the saved
// record is checked against the next identity instead of overwritten.
c.manualBindings[id] = current
if changed {
restored, seen := c.manualRestored[id]
if pending := seen && !restored; changed && !pending {
if hold, held := c.holds[id]; held {
if hold.PowerW > 0 {
c.holds[id] = ManualHold{Persistent: true}
Expand Down
17 changes: 12 additions & 5 deletions go/internal/loadpoint/manual_hold_state.go
Original file line number Diff line number Diff line change
Expand Up @@ -153,10 +153,12 @@ func (m *Manager) setManualPersistenceError(id string, err error) {
}
}

// RestoreManualHold returns pending until hardware identity is known. A
// verified same-session positive hold or a hardware-bound pause is restored.
// Unknown/changed sessions and legacy records return a persistent zero-W hold
// plus unconfirmed: failed restoration must not start automatic charging.
// RestoreManualHold returns pending until the record's proof is known: the
// hardware identity, and the session ID when the record has one. A record
// without a session ID is checked by hardware alone; most chargers never
// report one, and an observed unplug still ends the hold. Changed hardware or
// sessions and legacy records return a persistent zero-W hold plus
// unconfirmed: failed restoration must not start automatic charging.
func (m *Manager) RestoreManualHold(id string) (ManualHold, string) {
m.sessionMu.Lock()
defer m.sessionMu.Unlock()
Expand Down Expand Up @@ -227,9 +229,14 @@ func (m *Manager) RestoreManualHold(id string) (ManualHold, string) {
!record.Hold.ExpiresAt.IsZero() || !finite(record.Hold.PowerW) || record.Hold.PowerW < 0 {
return ManualHold{Persistent: true}, "unconfirmed"
}
if record.Hold.PowerW == 0 || (sessionID != "" && sessionID == record.SessionID) {
if record.Hold.PowerW == 0 || record.SessionID == "" || sessionID == record.SessionID {
return record.Hold, "restored"
}
if sessionID == "" {
// A charger can report its session after its identity. Deciding now
// would turn Charge now into a pause on every restart.
return ManualHold{Persistent: true}, "pending"
}
return ManualHold{Persistent: true}, "unconfirmed"
}

Expand Down
2 changes: 1 addition & 1 deletion go/internal/loadpoint/manual_hold_state_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -141,7 +141,7 @@ func TestManualHoldRestoreRequiresHardwareAndActiveSession(t *testing.T) {
}{
{"easee:ABC", "session-1", "restored", 4140},
{"easee:ABC", "session-2", "unconfirmed", 0},
{"easee:ABC", "", "unconfirmed", 0},
{"easee:ABC", "", "pending", 0},
{"easee:OTHER", "session-1", "unconfirmed", 0},
} {
m := sessionManager(store, "garage", "charger")
Expand Down
9 changes: 7 additions & 2 deletions go/internal/loadpoint/manual_unbound_state_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -18,11 +18,16 @@ func TestManualRestrictionSurvivesRestartWithoutHardwareIdentity(t *testing.T) {
restarted.ObserveSession("garage", true, 0, 1000, true, device, "")
c := NewController(restarted, nil, nil, nil)
c.restoreManualHoldForSession("garage")
if h, ok := c.GetManualHold("garage", time.Now()); !ok || !h.Persistent || h.PowerW != 0 {
// Only hardware identity can carry power across a restart.
want := 0.0
if device == "easee:ABC" {
want = watts
}
if h, ok := c.GetManualHold("garage", time.Now()); !ok || !h.Persistent || h.PowerW != want {
t.Fatalf("%q/%v: restart lost restriction: %+v %v", device, watts, h, ok)
}
st, _ := restarted.State("garage")
if st.ManualRestoreUnconfirmed != (watts > 0) {
if st.ManualRestoreUnconfirmed != (watts != want) {
t.Fatalf("%q/%v: confirmation=%v", device, watts, st.ManualRestoreUnconfirmed)
}
if err := restarted.PersistManualHold("garage", ManualHold{}, true); err != nil {
Expand Down
Loading