8 changes: 8 additions & 0 deletions .changeset/ems-battery-soc-max.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,8 @@
---
"ftw": patch
---

Stop battery charging at the configured maximum charge level in every EMS mode,
including manual holds and self-tuning. Use each battery's soc_max, or the
planner's limit when the battery has none. Charging resumes one percentage
point below that limit; discharge remains available.
68 changes: 68 additions & 0 deletions go/cmd/ftw/battery_soc_max_test.go
Original file line number Diff line number Diff line change
@@ -0,0 +1,68 @@
package main

import (
"testing"
"time"

"github.com/srcfl/ftw/go/internal/config"
"github.com/srcfl/ftw/go/internal/control"
"github.com/srcfl/ftw/go/internal/telemetry"
)

// The planner's earlier charge budget cannot override the owner's SoC limit.
// No solar or export is needed to reproduce the 10 kW order at 90%.
func TestConfiguredSoCMaxStopsDispatch(t *testing.T) {
for _, mode := range []control.Mode{control.ModeCharge, control.ModePlannerArbitrage} {
t.Run(string(mode), func(t *testing.T) {
cfg := parseBatteryLimitConfig(t, "", " soc_max: 0.9\n max_charge_w: 10000\n")
ctrl := newControlStateFromConfig(cfg)
ctrl.Mode = mode
ctrl.SlewEnabled = false
ctrl.UseEnergyDispatch = true
ctrl.SlotDirective = func(now time.Time) (control.SlotDirective, bool) {
return control.SlotDirective{
SlotStart: now, SlotEnd: now.Add(15 * time.Minute),
BatteryEnergyWh: 2500, PlannedGridW: 11000, HasPlannedGridW: true,
}, true
}
tel := batteryLimitStore(1000)
soc := 0.9
tel.Update("battery", telemetry.DerBattery, 0, &soc, nil)
got := control.ComputeDispatch(tel, ctrl, map[string]float64{"battery": 15000}, 40000)
if len(got) != 1 || got[0].TargetW != 0 {
t.Fatalf("soc_max=0.9 at 90%% sent %+v, want one 0 W target", got)
}
})
}
}

func TestSoCMaxConfigPrecedenceAndReload(t *testing.T) {
cfg := parseBatteryLimitConfig(t, "", " soc_max: 0.9\n")
cfg.Planner = &config.Planner{SoCMax: .8}
ctrl := newControlStateFromConfig(cfg)
ctrl.Mode, ctrl.SlewEnabled = control.ModeCharge, false
tel := batteryLimitStore(1000)
capacities := map[string]float64{"battery": 10000}
check := func(soc float64, charging bool) {
t.Helper()
tel.Update("battery", telemetry.DerBattery, 0, &soc, nil)
got := control.ComputeDispatch(tel, ctrl, capacities, 40000)
if len(got) != 1 || (got[0].TargetW > 0) != charging {
t.Fatalf("SoC %.2f: got %+v, want charging=%v", soc, got, charging)
}
}
check(.85, true) // The battery's 90% overrides the planner's 80%.
check(.9, false)
// The config watcher replaces the limits through this same function.
cfg.Batteries = nil
ctrl.DriverLimits = driverLimitsFrom(cfg.ModbusControlDrivers(), cfg.Batteries, cfg.Planner)
check(.85, false) // With no battery override, the planner's 80% applies.
cfg.Planner = nil
ctrl.DriverLimits = driverLimitsFrom(cfg.ModbusControlDrivers(), cfg.Batteries, cfg.Planner)
check(.99, true) // No configured ceiling keeps the 100% default.
check(1, false)
zero := 0.0
cfg.Batteries = map[string]config.Battery{"battery": {SoCMax: &zero}}
ctrl.DriverLimits = driverLimitsFrom(cfg.ModbusControlDrivers(), cfg.Batteries, cfg.Planner)
check(.5, false) // An explicit zero is not an absent limit.
}
11 changes: 10 additions & 1 deletion go/cmd/ftw/main.go
Original file line number Diff line number Diff line change
Expand Up @@ -3616,20 +3616,29 @@ func driverCapacitiesFrom(drvList []config.Driver, loadpoints []config.Loadpoint
}

// driverLimitsFrom gives dispatch the same per-driver limits as the planner,
// with each battery's floor: its soc_min, else the planner's (default 10 %).
// with each battery's SoC bounds, falling back to the planner's.
func driverLimitsFrom(drivers []config.Driver, batteries map[string]config.Battery, planner *config.Planner) map[string]control.PowerLimits {
floor := 0.10
ceiling := 1.0
if planner != nil && planner.SoCMin > 0 {
floor = planner.SoCMin
}
if planner != nil && planner.SoCMax > 0 {
ceiling = planner.SoCMax
}
out := map[string]control.PowerLimits{}
for _, d := range drivers {
if !d.ObserveOnly {
limits := batteryPowerLimits(d, batteries[d.Name])
limits.SoCMin = floor
limits.SoCMax = ceiling
if b := batteries[d.Name]; b.SoCMin != nil {
limits.SoCMin = *b.SoCMin
}
if b := batteries[d.Name]; b.SoCMax != nil {
limits.SoCMax = *b.SoCMax
limits.SoCMaxSet = true
}
out[d.Name] = limits
}
}
Expand Down
42 changes: 42 additions & 0 deletions go/internal/api/api_battery_soc_max_test.go
Original file line number Diff line number Diff line change
@@ -0,0 +1,42 @@
package api

import (
"encoding/json"
"sync"
"testing"
"testing/synctest"
"time"

"github.com/srcfl/ftw/go/internal/control"
"github.com/srcfl/ftw/go/internal/telemetry"
)

func TestSoCMaxFeedbackUsesTheDispatchResumeLevel(t *testing.T) {
synctest.Test(t, func(t *testing.T) {
tel := telemetry.NewStore()
soc := .9
tel.Update("battery", telemetry.DerBattery, 0, &soc, nil)
tel.RecordDriverSuccess("battery")
tel.Update("meter", telemetry.DerMeter, 1000, nil, nil)
tel.RecordDriverSuccess("meter")
st := control.NewState(0, 50, "meter")
st.Mode = control.ModeCharge
st.DriverLimits = map[string]control.PowerLimits{"battery": {SoCMax: .9}}
got := control.ComputeDispatch(tel, st, map[string]float64{"battery": 15000}, 13800)
if len(got) != 1 || got[0].TargetW != 0 {
t.Fatalf("charge not stopped: %+v", got)
}
request, _ := json.Marshal(map[string]any{"action": "battery", "power_w": 0})
cmd := tel.BeginCommand("battery", request, time.Now())
tel.CompleteCommand(cmd, "accepted")
for range 16 {
tel.Update("battery", telemetry.DerBattery, 0, &soc, []byte(`{"setpoint_w":0}`))
time.Sleep(3 * time.Second)
}
srv := New(&Deps{Tel: tel, Ctrl: st, CtrlMu: &sync.Mutex{}})
f := srv.controlFeedback(time.Now())[0]
if f.Status != "limited" || f.Reason != "battery_full" || f.Severity != "info" || f.ChargeResumeSoC == nil || *f.ChargeResumeSoC != .89 {
t.Fatalf("wrong explanation of the 90%% stop: %+v", f)
}
})
}
10 changes: 6 additions & 4 deletions go/internal/api/api_control_feedback.go
Original file line number Diff line number Diff line change
Expand Up @@ -84,7 +84,7 @@ func (s *Server) controlFeedback(now time.Time) []ControlFeedback {
}
mode, meter := "", ""
clamped := map[string]bool{}
full := map[string]bool{}
full := map[string]float64{}
targeted := map[string]bool{}
var hold control.BatteryManualHold
var held bool
Expand All @@ -94,7 +94,9 @@ func (s *Server) controlFeedback(now time.Time) []ControlFeedback {
meter = s.deps.Ctrl.SiteMeterDriver
for _, t := range s.deps.Ctrl.LastTargets {
clamped[t.Driver] = t.Clamped
full[t.Driver] = s.deps.Ctrl.BatteryChargePaused(t.Driver)
if s.deps.Ctrl.BatteryChargePaused(t.Driver) {
full[t.Driver] = s.deps.Ctrl.BatteryChargeResumeSoC(t.Driver)
}
targeted[t.Driver] = true
}
hold, held = s.deps.Ctrl.GetBatteryManualHold(now)
Expand Down Expand Up @@ -178,9 +180,9 @@ func (s *Server) controlFeedback(now time.Time) []ControlFeedback {
if clamped[rd.Driver] && kind == telemetry.DerBattery {
coreReason = "core_limit"
}
if full[rd.Driver] && kind == telemetry.DerBattery && f.BatterySoC != nil {
if resume, paused := full[rd.Driver]; paused && kind == telemetry.DerBattery && f.BatterySoC != nil {
coreReason = "battery_full"
f.ChargeResumeSoC = watts(control.BatteryChargeResumeSoC)
f.ChargeResumeSoC = watts(resume)
}
if held && kind == telemetry.DerBattery && (hold.Driver == "" || hold.Driver == rd.Driver) {
f.Mode = "manual"
Expand Down
18 changes: 13 additions & 5 deletions go/internal/control/battery_full.go
Original file line number Diff line number Diff line change
Expand Up @@ -6,9 +6,14 @@ import (
"github.com/srcfl/ftw/go/internal/telemetry"
)

// A one percentage point gap prevents repeated starts at a rounded 100%.
// This limits charging only; the plan can discharge a full battery at once.
const BatteryChargeResumeSoC = 0.99
// A one percentage point gap prevents repeated starts at the charge ceiling.
const batteryChargeHysteresisSoC = 0.01

// BatteryChargeResumeSoC uses the same ceiling as dispatch. Callers hold the
// control lock, as they do for BatteryChargePaused.
func (s *State) BatteryChargeResumeSoC(driver string) float64 {
return math.Max(0, s.DriverLimits[driver].socCeiling()-batteryChargeHysteresisSoC)
}

// BatteryChargePaused reports the dispatcher's full-battery stop. Callers use
// the same lock as ComputeDispatch; this state is local to the running device.
Expand All @@ -17,6 +22,9 @@ func (s *State) BatteryChargePaused(driver string) bool {
}

func (s *State) updateBatteryChargeFull(store *telemetry.Store, capacities map[string]float64) {
if s == nil || store == nil {
return
}
if s.batteryChargeFull == nil {
s.batteryChargeFull = map[string]bool{}
}
Expand All @@ -36,9 +44,9 @@ func (s *State) updateBatteryChargeFull(store *telemetry.Store, capacities map[s
if age < 0 || age > telemetry.BatterySoCMaxAge || math.IsNaN(soc) || math.IsInf(soc, 0) || soc < 0 || soc > 1 {
continue
}
if soc == 1 {
if soc >= s.DriverLimits[name].socCeiling() {
s.batteryChargeFull[name] = true
} else if soc <= BatteryChargeResumeSoC {
} else if soc <= s.BatteryChargeResumeSoC(name) {
delete(s.batteryChargeFull, name)
}
}
Expand Down
154 changes: 154 additions & 0 deletions go/internal/control/battery_soc_max_test.go
Original file line number Diff line number Diff line change
@@ -0,0 +1,154 @@
package control

import (
"testing"
"testing/synctest"
"time"

"github.com/srcfl/ftw/go/internal/telemetry"
)

func cappedBatterySite(soc, power float64) (*telemetry.Store, *State, map[string]float64) {
tel, st, capacities := fullBatterySite(soc, power)
st.DriverLimits = map[string]PowerLimits{"battery": {SoCMax: .9, MaxChargeW: 10000}}
return tel, st, capacities
}

func TestSoCMaxStopsChargingInEveryMode(t *testing.T) {
for _, mode := range AllModes() {
for _, energy := range []bool{false, true} {
t.Run(string(mode)+"/energy="+map[bool]string{false: "off", true: "on"}[energy], func(t *testing.T) {
tel, st, capacities := cappedBatterySite(.9, 2000)
st.Mode, st.UseEnergyDispatch = mode, energy
st.SlewEnabled, st.SlewRateW = true, 10
st.SlotDirective = func(now time.Time) (SlotDirective, bool) {
return SlotDirective{SlotStart: now, SlotEnd: now.Add(15 * time.Minute), BatteryEnergyWh: 500}, true
}
st.PlanTarget = func(time.Time) (string, float64, string, bool) {
return string(ModeCharge), 2000, "charge", true
}
got := ComputeDispatch(tel, st, capacities, 13800)
if len(got) != 1 || got[0].TargetW > 0 || !st.BatteryChargePaused("battery") {
t.Fatalf("90%% ceiling did not stop charging: %+v", got)
}
})
}
}
}

func TestSoCMaxManualHoldAndSibling(t *testing.T) {
tel, st, capacities := cappedBatterySite(.9, 0)
tel.Update("other", telemetry.DerBattery, 0, ptrF64(.8), nil)
tel.RecordDriverSuccess("other")
capacities["other"] = 9600
st.DriverLimits["other"] = PowerLimits{SoCMax: .95}
st.SlewEnabled = false
st.SetBatteryManualHold(BatteryManualHold{PowerW: 3000, ExpiresAt: time.Now().Add(time.Hour)})
got := ComputeDispatch(tel, st, capacities, 13800)
if targetFor(t, got, "battery").TargetW != 0 || targetFor(t, got, "other").TargetW < 2900 {
t.Fatalf("charge must go to the battery below its own ceiling: %+v", got)
}
st.SetBatteryManualHold(BatteryManualHold{PowerW: -2000, ExpiresAt: time.Now().Add(time.Hour)})
got = ComputeDispatch(tel, st, capacities, 13800)
if targetFor(t, got, "battery").TargetW >= 0 {
t.Fatalf("charge ceiling blocked discharge: %+v", got)
}
st.BatteryHoldTargetValid = func(driver, id string) bool { return driver == "battery" && id == "hardware" }
st.SetBatteryManualHold(BatteryManualHold{Driver: "battery", DeviceID: "hardware", PowerW: 3000, ExpiresAt: time.Now().Add(time.Hour)})
got = ComputeDispatch(tel, st, capacities, 13800)
if targetFor(t, got, "battery").TargetW != 0 || targetFor(t, got, "other").TargetW != 0 {
t.Fatalf("scoped hold bypassed its ceiling or charged another battery: %+v", got)
}
}

func TestSoCMaxStopsSelfTuneWithoutPriorControlTick(t *testing.T) {
tel, st, capacities := cappedBatterySite(.9, 1000)
got := SelfTuneDispatch(tel, st, capacities, 13800, "battery", 3000)
if len(got) != 1 || got[0].TargetW != 0 || !got[0].Clamped {
t.Fatalf("self-tune crossed the charge ceiling: %+v", got)
}
}

func TestSoCMaxStopsPreviousOrderDuringQuietOrHeldTick(t *testing.T) {
for _, holdoff := range []bool{false, true} {
tel, st, capacities := cappedBatterySite(.9, 0)
st.Mode = ModeSelfConsumption
tel.Update("ferroamp", telemetry.DerMeter, 0, nil, nil)
st.PrevTargets["battery"] = 10000
st.LastTargets = []DispatchTarget{{Driver: "battery", TargetW: 10000}}
if holdoff {
now := time.Now()
st.LastDispatch, st.MinDispatchIntervalS = &now, 60
}
got := ComputeDispatch(tel, st, capacities, 13800)
if len(got) != 1 || got[0].TargetW != 0 || st.LastTargets[0].TargetW != 0 || st.PrevTargets["battery"] != 0 {
t.Fatalf("holdoff=%v left the prior charge active: %+v", holdoff, got)
}
}
}

func TestSoCMaxHysteresisAndMissingLevel(t *testing.T) {
synctest.Test(t, func(t *testing.T) {
tel, st, capacities := cappedBatterySite(.899, 0)
check := func(paused bool) {
t.Helper()
got := ComputeDispatch(tel, st, capacities, 13800)
if len(got) != 1 || st.BatteryChargePaused("battery") != paused || (got[0].TargetW == 0) != paused {
t.Fatalf("paused=%v targets=%+v, want paused=%v", st.BatteryChargePaused("battery"), got, paused)
}
}
check(false)
for _, level := range []float64{.9, .92, .899, .891} {
tel.Update("battery", telemetry.DerBattery, 0, &level, nil)
check(true)
}
time.Sleep(6 * time.Minute)
tel.Update("battery", telemetry.DerBattery, 0, nil, nil)
tel.RecordDriverSuccess("battery")
check(true)
tel.Update("battery", telemetry.DerBattery, 0, ptrF64(.89), nil)
check(false)
})
}

func TestSoCMaxReloadTakesEffectOnNextTick(t *testing.T) {
tel, st, capacities := cappedBatterySite(.9, 0)
ComputeDispatch(tel, st, capacities, 13800)
st.DriverLimits["battery"] = PowerLimits{SoCMax: .95}
got := ComputeDispatch(tel, st, capacities, 13800)
if len(got) != 1 || got[0].TargetW <= 0 {
t.Fatalf("raising the ceiling did not release the stop: %+v", got)
}
st.DriverLimits["battery"] = PowerLimits{SoCMax: .85}
got = ComputeDispatch(tel, st, capacities, 13800)
if len(got) != 1 || got[0].TargetW != 0 {
t.Fatalf("lowering the ceiling did not stop charging: %+v", got)
}
}

func TestSoCMaxStillAllowsFuseRelief(t *testing.T) {
tel, st, capacities := cappedBatterySite(.9, 0)
tel.Update("ferroamp", telemetry.DerMeter, 16000, nil, nil)
st.Mode = ModeIdle
describeFuse(st, 13800)
got := ComputeDispatch(tel, st, capacities, 13800)
if len(got) != 1 || got[0].TargetW >= 0 {
t.Fatalf("charge ceiling blocked fuse relief: %+v", got)
}
}

func TestSoCMaxExportGuardCannotRestorePausedCharge(t *testing.T) {
tel, st, capacities := cappedBatterySite(.9, 2000)
st.Mode = ModeIdle
describeFuse(st, 13800)
st.batteryCommands = map[string]commandLog{"battery": commandLog{}.add(st.now(), 2000)}
st.updateBatteryChargeFull(tel, capacities)
// The stop remains active below the ceiling until the resume level. Even
// an export overage must not restore the charge that the stop removed.
tel.Update("battery", telemetry.DerBattery, 2000, ptrF64(.895), nil)
tel.Update("ferroamp", telemetry.DerMeter, -20000, nil, nil)
got := ComputeDispatch(tel, st, capacities, 13800)
if len(got) != 1 || got[0].TargetW != 0 {
t.Fatalf("export guard restored paused charging: %+v", got)
}
}
Loading
Loading