5 changes: 5 additions & 0 deletions .changeset/c6-idle-one-phase-start.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,5 @@
---
"ftw": patch
---

Start Charge now on one phase once there is room for 6 A on that phase. An idle charger set to `1p` or `auto` on a three-phase site waited for room for the three-phase minimum (4,140 W) on a single phase, so it never started on a 16 A fuse and rarely on 25 A. It now waits for room for its own least order, 1,380 W.
123 changes: 123 additions & 0 deletions go/internal/control/ev_fuse_one_phase_start_test.go
Original file line number Diff line number Diff line change
@@ -0,0 +1,123 @@
package control

import (
"testing"
"time"

"github.com/srcfl/ftw/go/internal/loadpoint"
)

// C6 (rig seeds 207534, 207536, 207537, 207531): an idle pool whose order
// lands on one phase needs room for 6 A on that phase, not for the
// configured three-phase minimum of 4,140 W. Without that, Charge now on 1p
// or auto never starts on a 16 A fuse ("below minimum step … fuse_cap_w=0
// min_step_w=1380").
func TestIdleOnePhasePoolStartsOnSixAmpsOfRoom(t *testing.T) {
steps := []float64{0, 1380, 1610, 1840, 2070, 2300, 2530, 2760, 2990, 3220, 3450, 3680,
4140, 4830, 5520, 6210, 6900, 7590, 8280, 8970, 9660, 10350, 11040}
for _, tc := range []struct {
name string
fuseA float64
houseA float64
mode string
holdW float64
}{
{"16A 1p", 16, 4.5, "1p", 3680},
{"25A 1p", 25, 13.7, "1p", 3680},
{"16A auto", 16, 4.5, "auto", 3680},
{"25A auto", 25, 13.7, "auto", 3680},
} {
t.Run(tc.name, func(t *testing.T) {
cfg := loadpoint.Config{ID: "garage", DriverName: "easee", MinChargeW: 4140, MaxChargeW: 11040,
PhaseMode: "auto", AllowedStepsW: steps}
s := newPhaseSite(t, cfg, tc.houseA)
fuseW := tc.fuseA * 230 * 3
s.state.SiteFuseAmps = tc.fuseA
s.ctrl.SetSiteFuse(loadpoint.SiteFuse{MaxAmps: tc.fuseA, Voltage: 230, PhaseCnt: 3})
s.ctrl.SetFuseEVMax(func() (float64, bool) {
return EVFuseBudget(s.store, s.state, s.mgr.States(), s.ctrl.FuseConfigs(), fuseW)
})
s.ctrl.SetManualHold(cfg.ID, loadpoint.ManualHold{PowerW: tc.holdW, PhaseMode: tc.mode, Persistent: true})
start := s.now
deadline := start.Add(evRestartDwell + 5*time.Second) // the dwell plus one 5 s tick
for s.now.Before(deadline) && s.offerW < 1380 {
s.tick()
}
st, _ := s.mgr.State(cfg.ID)
if s.offerW < 1380 {
t.Fatalf("after %s: offer %.0f W, EV cap %.0f W, reason %q; want at least 1380 W",
s.now.Sub(start), s.offerW, s.state.evLimit.capW, st.CommandedReason)
}
t.Logf("started after %s at %.0f W on one phase", s.now.Sub(start), s.offerW)
if !s.offer1p {
t.Fatalf("offer %.0f W runs on three phases; want one", s.offerW)
}
for i := 0; i < 12; i++ {
s.tick()
if s.worstA() > tc.fuseA {
t.Fatalf("offer %.0f W puts %.1f A on a %.0f A fuse", s.offerW, s.worstA(), tc.fuseA)
}
}
})
}
}

// The start point is exact: on a 16 A fuse an idle 1p or auto pool starts at
// 1,380 W, its least order, once the worst phase leaves 6 A of room under the
// working line, and waits while it leaves 5.7 A. A hidden margin on the
// one-phase minimum would move the start and fail here. The cases are set
// from the working line as EVFuseBudget reports it, not from the constant
// that sets it, so they follow the line if it moves.
func TestIdleOnePhasePoolStartBoundary(t *testing.T) {
steps := []float64{0, 1380, 1610, 1840, 2070, 2300, 2530, 2760, 2990, 3220, 3450, 3680,
4140, 4830, 5520, 6210, 6900, 7590, 8280, 8970, 9660, 10350, 11040}
const fuseA = 16.0
site := func(t *testing.T, houseA float64, mode string) *phaseSite {
cfg := loadpoint.Config{ID: "garage", DriverName: "easee", MinChargeW: 4140, MaxChargeW: 11040,
PhaseMode: "auto", AllowedStepsW: steps}
s := newPhaseSite(t, cfg, houseA)
s.state.SiteFuseAmps = fuseA
s.ctrl.SetSiteFuse(loadpoint.SiteFuse{MaxAmps: fuseA, Voltage: 230, PhaseCnt: 3})
s.ctrl.SetFuseEVMax(func() (float64, bool) {
return EVFuseBudget(s.store, s.state, s.mgr.States(), s.ctrl.FuseConfigs(), fuseA*230*3)
})
s.ctrl.SetManualHold(cfg.ID, loadpoint.ManualHold{PowerW: 3680, PhaseMode: mode, Persistent: true})
return s
}
// With no house load, an idle pool's room on its busiest phase is the
// whole working line.
probe := site(t, 0, "1p")
probe.tick()
lineA := probe.state.evLimit.phaseRoomA
if !probe.state.evLimit.phaseRoomKnown || lineA <= 6 || lineA > fuseA {
t.Fatalf("working line %.2f A (known %v) on a %.0f A fuse", lineA, probe.state.evLimit.phaseRoomKnown, fuseA)
}
for _, mode := range []string{"1p", "auto"} {
t.Run(mode+" 6.0 A of room starts", func(t *testing.T) {
s := site(t, lineA-6, mode)
start := s.now
for s.now.Sub(start) < evRestartDwell+5*time.Second && s.offerW == 0 {
s.tick()
}
if s.offerW != 1380 || !s.offer1p {
t.Fatalf("worst phase %.1f A: offer %.0f W, one phase %v; want 1380 W on one phase",
lineA-6, s.offerW, s.offer1p)
}
for i := 0; i < 60; i++ {
s.tick()
if s.worstA() > fuseA {
t.Fatalf("tick %d: %.2f A on a %.0f A fuse", i, s.worstA(), fuseA)
}
}
})
t.Run(mode+" 5.7 A of room waits", func(t *testing.T) {
s := site(t, lineA-5.7, mode)
for i := 0; i < 40; i++ {
s.tick()
if s.offerW != 0 {
t.Fatalf("tick %d: offer %.0f W with 5.7 A of room; want 0", i, s.offerW)
}
}
})
}
}
9 changes: 6 additions & 3 deletions go/internal/loadpoint/controller_fuse_budget.go
Original file line number Diff line number Diff line change
Expand Up @@ -221,13 +221,16 @@ func (c *Controller) phaseRoomCapW(id, mode string, wantW, split, roomA float64)
}

// FuseConfigs returns the loadpoints with the phase mode each command names
// this tick. control.EVFuseBudget measures room on those phases, so an auto
// or 1p offer never gets three phases of room. Outside a tick, and for a
// loadpoint that gets no command, the configured mode stands.
// this tick, and the least each can order on those phases.
// control.EVFuseBudget measures room on those phases, so an auto or 1p offer
// never gets three phases of room, and an idle pool waits for room for that
// least order, not the configured three-phase minimum. Outside a tick, and
// for a loadpoint that gets no command, the configured mode stands.
func (c *Controller) FuseConfigs() []Config {
configs := c.manager.Configs()
for i := range configs {
if mode := c.tickChoices[configs[i].ID].phaseMode; mode != "" {
configs[i] = c.fuseConfig(configs[i], mode)
configs[i].PhaseMode = mode
}
}
Expand Down