Skip to content

ConBee II stops receiving frames ~15-30 min after start since zigpy-deconz 1.1.1: TX still confirms #283

Closed

Description

@ErikBavenstrand

Problem

After updating HA from 2026.10.4 to 2026.11.1, my ConBee II stops receiving anything about 15-30 min after ZHA starts. It stays CONNECTED and sends still get aps_data_confirm with SUCCESS, but no aps_data_indication arrives after that. Every device then goes unavailable.

Downgrading to 2026.10.4 fixed it. It has been fine for 80+ min now; on 2026.11.1 it failed after every start.

works broken
HA 2026.10.4 2026.11.0, 2026.11.1
zha 2.3.1 2.4.2, 2.4.3
zigpy 2.3.0 2.4.1
zigpy-deconz 1.0.0 1.1.1

ConBee II, firmware 0x26720700 and later 0x26780700, same result on both. HAOS 18.4 in a Proxmox VM with USB passthrough, about 16 devices on channel 15.

What I see

  • All devices stop being heard at the same moment, e.g. every last_seen stops between 19:41 and 19:53 on a network started at 19:16.
  • After that, a debug log shows only sends, confirms and the watchdog. An example confirm: 0x045b0013000c00221602e73d01010000000000.
  • Reloading ZHA doesn't bring the traffic back.
  • Every ~4 h I get three of these:
    Unexpected transmit confirm for request id 185, Status: TXStatus.SUCCESS
    
  • Network settings and the frame counter are unchanged. The host shows no USB disconnects.
  • Endpoint slots at startup: slot 0 has EP 1 and slot 1 has EP 242. On 1.0.0, slot 1 had EP 2.

Suspect

The endpoint changes in 1.1.1 (#279, #281, application.py#L540), which now put EP 242 in slot 1. Related: #280, #234. It could also be the zigpy 2.4.1 update; I haven't tested that separately.

I can capture a debug log from start until it goes quiet if that helps.

Activity

  1. puddly commented on Nov 17, 2026

    @puddly
    Member

    Endpoints for the Conbee II really don't do much beyond filtering, they shouldn't have any delayed impact like this.

    Can you narrow down what package is causing this behavior?

  2. added
    regression
    on Nov 17, 2026
  3. zigpy-review-bot commented on Nov 17, 2026

    @zigpy-review-bot
    Collaborator

    A few facts that bear on narrowing this down:

    • The confirm you quoted shows the stick isn't holding any received frame for the host. Its device state byte is 0x22: network CONNECTED, free TX slots, and the "APS data indication pending" flag clear. zigpy-deconz only reads incoming frames when the stick sets that flag, and that receive path is the same in 1.0.0 and 1.1.1. So the frames aren't being lost on the host after the stick reports them: the stick stops reporting any.
    • zigpy and zigpy-deconz can't be swapped one at a time here. zigpy-deconz 1.1.x requires zigpy 2.4.0 or newer, and zigpy 2.4.0 is the release that started registering the Green Power endpoint 242. zigpy-deconz 1.0.0 predates that endpoint and can't place it on two-slot firmware: depending on what the slots hold, it either fails to start (ConBee II / RaspBee II fail to start since zigpy 2.4.0: no endpoint slot left for the Green Power endpoint 242 #280) or writes EP 2 and then 242 into the same slot on every start. On HA 2026.11 the two only work as a pair.
    • The Green Power code new in zigpy 2.4 sends nothing on a timer. It only sends while joining is open, or when a Green Power device is paired or removed.
    • Slot 0 = EP 1 (HA profile) and slot 1 = EP 242 (Green Power profile) is the same layout Zigbee2MQTT writes on a ConBee II. The EP 242 descriptors differ, though: Zigbee2MQTT uses device type 0x0064 with Green Power as an output cluster only, and zigpy uses 0x0066 with it as input and output.

    Two things would help:

    1. The debug log you offered, from HA start until it goes quiet. Please use this in configuration.yaml so startup is included, and restart:
    logger:
      default: info
      logs:
        homeassistant.components.zha: debug
        zha: debug
        zigpy: debug
        zigpy_deconz: debug

    The useful part is the last few minutes before the last received frame, plus the startup lines showing the endpoint slots.
    2. On 2026.11.1, once it has gone quiet: does unplugging the ConBee II (or detaching and re-attaching it in Proxmox) and then restarting HA bring traffic back for another 15-30 minutes? zigpy-deconz sends the stick no reset when ZHA reloads, so this shows whether the stick needs a power cycle to recover.

    What was checked
  4. added
    waiting for reply
    on Nov 17, 2026
  5. ErikBavenstrand commented on Nov 20, 2026

    @ErikBavenstrand
    Author

    After some further testing I've narrowed it down to my two SONOFF nodes which seems to be in a perpetual reconnect state that essentially drags the entire network down with it.

    So I think this issue can be closed since this is a SONOFF issue rather than Conbee :)

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    regressionwaiting for reply

    Type

    Fields

    Priority

    None yet

    Size

    None yet

    Area

    None yet

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions