5 changes: 3 additions & 2 deletions packages/control/algorithm/surplus_controlled.py
Original file line number Diff line number Diff line change
Expand Up @@ -95,9 +95,10 @@ def _set_loadmangement_message(self,
limit: LoadmanagementLimit,
load: Load) -> None:
# Strom muss an diesem Zähler geändert werden
if (current != load.data.set.current and
if ((load.data.set.current is None or round(current, 2) != round(load.data.set.current, 2)) and
# Strom erreicht nicht die vorgegebene Stromstärke
current != max(load.data.control_parameter.required_currents) and
round(current, 2) != round(max(load.data.control_parameter.required_currents), 2) and
limit.message is not None and
# im PV-Laden wird der Strom immer durch die Leistung begrenzt
limit.limiting_value != LimitingValue.POWER):
load.set_state_and_log(f"Es kann nicht mit der vorgegebenen Stromstärke geladen werden"
Expand Down
37 changes: 37 additions & 0 deletions packages/control/algorithm/surplus_controlled_test.py
Original file line number Diff line number Diff line change
Expand Up @@ -14,6 +14,8 @@
from control.chargepoint.control_parameter import ControlParameter
from control.counter_all.counter_all import CounterAll
from control.ev.ev import Ev
from control.consumer.consumer import Consumer
from control.limiting_value import LimitingValue, LoadmanagementLimit


@pytest.fixture(autouse=True)
Expand Down Expand Up @@ -42,6 +44,41 @@ def mock_data() -> None:
data.data.counter_all_data = CounterAll()


@pytest.mark.parametrize(
"current, set_current, required_current, limit, expected_message",
[
pytest.param(13.04, 6, 13.043478260869565,
LoadmanagementLimit(None, None), None, id="reported-consumer-rounding"),
pytest.param(12, 6, 13.04, LoadmanagementLimit(None, None), None,
id="no-limit-reason"),
pytest.param(13.04, 6, 13.043478260869565,
LoadmanagementLimit(" current limit", LimitingValue.CURRENT), None,
id="rounded-required-current"),
pytest.param(13.04, 13.043478260869565, 16,
LoadmanagementLimit(" current limit", LimitingValue.CURRENT), None,
id="rounded-unchanged-current"),
pytest.param(12, 6, 13.04,
LoadmanagementLimit(" power limit", LimitingValue.POWER), None,
id="normal-pv-power-limit"),
pytest.param(12, 6, 13.04,
LoadmanagementLimit(" current limit", LimitingValue.CURRENT),
"Es kann nicht mit der vorgegebenen Stromstärke geladen werden current limit",
id="actual-current-limit"),
pytest.param(12, None, 13.04,
LoadmanagementLimit(" current limit", LimitingValue.CURRENT),
"Es kann nicht mit der vorgegebenen Stromstärke geladen werden current limit",
id="no-previous-set-current"),
])
def test_set_loadmanagement_message(current, set_current, required_current, limit, expected_message):
consumer = Consumer(27)
consumer.data.set.current = set_current
consumer.data.control_parameter.required_currents = [required_current, 0, 0]

SurplusControlled()._set_loadmangement_message(current, limit, consumer)

assert consumer.data.get.state_str == expected_message


@pytest.mark.parametrize("new_current, expected_current",
[
pytest.param(7, 10),
Expand Down